Double Assurance of Epidural Space Detection Using Fiberoptics-Based Needle Design and Autofluorescence Technologies for Epidural Blockade in Painless Labor
Purpose: Technology of reflectance spectroscopy incorporated with auto-fluorescence spectroscopy were employed to increase the safety of epidural placement in regional anesthesia which is generally used for surgery, epidural anesthesia, post-operative pain control and painless childbirth. Method: Ex...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6264018/ https://www.ncbi.nlm.nih.gov/pubmed/30360473 http://dx.doi.org/10.3390/s18113592 |
_version_ | 1783375399344930816 |
---|---|
author | Gong, Cihun-Siyong Alex Lee, Huang-Chang Chang, Yin Ting, Chien-Kun Tu, Po-Hsun |
author_facet | Gong, Cihun-Siyong Alex Lee, Huang-Chang Chang, Yin Ting, Chien-Kun Tu, Po-Hsun |
author_sort | Gong, Cihun-Siyong Alex |
collection | PubMed |
description | Purpose: Technology of reflectance spectroscopy incorporated with auto-fluorescence spectroscopy were employed to increase the safety of epidural placement in regional anesthesia which is generally used for surgery, epidural anesthesia, post-operative pain control and painless childbirth. Method: Ex vivo study of auto-fluorescence spectroscopy was performed for the para-vertebral tissues contained fat, interspinous ligament, supraspinous ligament and ligamentumflavum by multimode microplate reader at wavelength 405 nm for the purpose of tissue differentiation. A specially designed optic-fiber-embedded needle was employed to incorporate with both reflectance and autofluorescence spectroscopies in order to probe the epidural space as double assurance demands. In vivo study was carried out in a Chinese native swine weighted about 30 kg under intubated general anesthesia with ventilation support. The reflective (405 nm) and autofluorescence signals (λ and λ*) were recorded at 5 different sites by an oscilloscope during the needle puncture procedure from skin to epidural space in the back of the swine. Results: Study of either autofluorescence spectroscopy for tissue samples or ex vivo needle puncture in porcine trunk tissues indicates that ligmentumflavum has at least 10-fold higher fluorescence intensity than the other tissues. In the in vivo study, ligamentumflavum shows a double-peak character for both reflectance and autofluorescence signals. The epidural space is located right after the drop from the double-peak. Both peaks of reflectance and fluorescence are coincident which ensures that the epidural space is correctly detected. Conclusions: The fiber-optical technologies of double-assurance demands for tissue discrimination during epidural needle puncture can not only provide an objective visual information in a real-time fashion but also it can help the operator to achieve much higher success rate in this anesthesia procedure. |
format | Online Article Text |
id | pubmed-6264018 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-62640182018-12-12 Double Assurance of Epidural Space Detection Using Fiberoptics-Based Needle Design and Autofluorescence Technologies for Epidural Blockade in Painless Labor Gong, Cihun-Siyong Alex Lee, Huang-Chang Chang, Yin Ting, Chien-Kun Tu, Po-Hsun Sensors (Basel) Article Purpose: Technology of reflectance spectroscopy incorporated with auto-fluorescence spectroscopy were employed to increase the safety of epidural placement in regional anesthesia which is generally used for surgery, epidural anesthesia, post-operative pain control and painless childbirth. Method: Ex vivo study of auto-fluorescence spectroscopy was performed for the para-vertebral tissues contained fat, interspinous ligament, supraspinous ligament and ligamentumflavum by multimode microplate reader at wavelength 405 nm for the purpose of tissue differentiation. A specially designed optic-fiber-embedded needle was employed to incorporate with both reflectance and autofluorescence spectroscopies in order to probe the epidural space as double assurance demands. In vivo study was carried out in a Chinese native swine weighted about 30 kg under intubated general anesthesia with ventilation support. The reflective (405 nm) and autofluorescence signals (λ and λ*) were recorded at 5 different sites by an oscilloscope during the needle puncture procedure from skin to epidural space in the back of the swine. Results: Study of either autofluorescence spectroscopy for tissue samples or ex vivo needle puncture in porcine trunk tissues indicates that ligmentumflavum has at least 10-fold higher fluorescence intensity than the other tissues. In the in vivo study, ligamentumflavum shows a double-peak character for both reflectance and autofluorescence signals. The epidural space is located right after the drop from the double-peak. Both peaks of reflectance and fluorescence are coincident which ensures that the epidural space is correctly detected. Conclusions: The fiber-optical technologies of double-assurance demands for tissue discrimination during epidural needle puncture can not only provide an objective visual information in a real-time fashion but also it can help the operator to achieve much higher success rate in this anesthesia procedure. MDPI 2018-10-23 /pmc/articles/PMC6264018/ /pubmed/30360473 http://dx.doi.org/10.3390/s18113592 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Gong, Cihun-Siyong Alex Lee, Huang-Chang Chang, Yin Ting, Chien-Kun Tu, Po-Hsun Double Assurance of Epidural Space Detection Using Fiberoptics-Based Needle Design and Autofluorescence Technologies for Epidural Blockade in Painless Labor |
title | Double Assurance of Epidural Space Detection Using Fiberoptics-Based Needle Design and Autofluorescence Technologies for Epidural Blockade in Painless Labor |
title_full | Double Assurance of Epidural Space Detection Using Fiberoptics-Based Needle Design and Autofluorescence Technologies for Epidural Blockade in Painless Labor |
title_fullStr | Double Assurance of Epidural Space Detection Using Fiberoptics-Based Needle Design and Autofluorescence Technologies for Epidural Blockade in Painless Labor |
title_full_unstemmed | Double Assurance of Epidural Space Detection Using Fiberoptics-Based Needle Design and Autofluorescence Technologies for Epidural Blockade in Painless Labor |
title_short | Double Assurance of Epidural Space Detection Using Fiberoptics-Based Needle Design and Autofluorescence Technologies for Epidural Blockade in Painless Labor |
title_sort | double assurance of epidural space detection using fiberoptics-based needle design and autofluorescence technologies for epidural blockade in painless labor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6264018/ https://www.ncbi.nlm.nih.gov/pubmed/30360473 http://dx.doi.org/10.3390/s18113592 |
work_keys_str_mv | AT gongcihunsiyongalex doubleassuranceofepiduralspacedetectionusingfiberopticsbasedneedledesignandautofluorescencetechnologiesforepiduralblockadeinpainlesslabor AT leehuangchang doubleassuranceofepiduralspacedetectionusingfiberopticsbasedneedledesignandautofluorescencetechnologiesforepiduralblockadeinpainlesslabor AT changyin doubleassuranceofepiduralspacedetectionusingfiberopticsbasedneedledesignandautofluorescencetechnologiesforepiduralblockadeinpainlesslabor AT tingchienkun doubleassuranceofepiduralspacedetectionusingfiberopticsbasedneedledesignandautofluorescencetechnologiesforepiduralblockadeinpainlesslabor AT tupohsun doubleassuranceofepiduralspacedetectionusingfiberopticsbasedneedledesignandautofluorescencetechnologiesforepiduralblockadeinpainlesslabor |