Cargando…
Measuring Linewidth Enhancement Factor by Relaxation Oscillation Frequency in a Laser with Optical Feedback
This paper presents a new method for measuring the linewidth enhancement factor (alpha factor) by the relaxation oscillation (RO) frequency of a laser with external optical feedback (EOF). A measurement formula for alpha is derived which shows the alpha can be determined by only using the RO frequen...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6264022/ https://www.ncbi.nlm.nih.gov/pubmed/30453577 http://dx.doi.org/10.3390/s18114004 |
_version_ | 1783375400270823424 |
---|---|
author | Ruan, Yuxi Liu, Bin Yu, Yanguang Xi, Jiangtao Guo, Qinghua Tong, Jun |
author_facet | Ruan, Yuxi Liu, Bin Yu, Yanguang Xi, Jiangtao Guo, Qinghua Tong, Jun |
author_sort | Ruan, Yuxi |
collection | PubMed |
description | This paper presents a new method for measuring the linewidth enhancement factor (alpha factor) by the relaxation oscillation (RO) frequency of a laser with external optical feedback (EOF). A measurement formula for alpha is derived which shows the alpha can be determined by only using the RO frequencies and no need to know any other parameters related to the internal or external parameters associated to the laser. Unlike the existing EOF based alpha measurement methods which require an external target has a symmetric reciprocate movement. The proposed method only needs to move the target to be in a few different positions along the light beam. Furthermore, this method also suits for the case with alpha less than 1. Both simulation and experiment are performed to verify the proposed method. |
format | Online Article Text |
id | pubmed-6264022 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-62640222018-12-12 Measuring Linewidth Enhancement Factor by Relaxation Oscillation Frequency in a Laser with Optical Feedback Ruan, Yuxi Liu, Bin Yu, Yanguang Xi, Jiangtao Guo, Qinghua Tong, Jun Sensors (Basel) Article This paper presents a new method for measuring the linewidth enhancement factor (alpha factor) by the relaxation oscillation (RO) frequency of a laser with external optical feedback (EOF). A measurement formula for alpha is derived which shows the alpha can be determined by only using the RO frequencies and no need to know any other parameters related to the internal or external parameters associated to the laser. Unlike the existing EOF based alpha measurement methods which require an external target has a symmetric reciprocate movement. The proposed method only needs to move the target to be in a few different positions along the light beam. Furthermore, this method also suits for the case with alpha less than 1. Both simulation and experiment are performed to verify the proposed method. MDPI 2018-11-16 /pmc/articles/PMC6264022/ /pubmed/30453577 http://dx.doi.org/10.3390/s18114004 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ruan, Yuxi Liu, Bin Yu, Yanguang Xi, Jiangtao Guo, Qinghua Tong, Jun Measuring Linewidth Enhancement Factor by Relaxation Oscillation Frequency in a Laser with Optical Feedback |
title | Measuring Linewidth Enhancement Factor by Relaxation Oscillation Frequency in a Laser with Optical Feedback |
title_full | Measuring Linewidth Enhancement Factor by Relaxation Oscillation Frequency in a Laser with Optical Feedback |
title_fullStr | Measuring Linewidth Enhancement Factor by Relaxation Oscillation Frequency in a Laser with Optical Feedback |
title_full_unstemmed | Measuring Linewidth Enhancement Factor by Relaxation Oscillation Frequency in a Laser with Optical Feedback |
title_short | Measuring Linewidth Enhancement Factor by Relaxation Oscillation Frequency in a Laser with Optical Feedback |
title_sort | measuring linewidth enhancement factor by relaxation oscillation frequency in a laser with optical feedback |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6264022/ https://www.ncbi.nlm.nih.gov/pubmed/30453577 http://dx.doi.org/10.3390/s18114004 |
work_keys_str_mv | AT ruanyuxi measuringlinewidthenhancementfactorbyrelaxationoscillationfrequencyinalaserwithopticalfeedback AT liubin measuringlinewidthenhancementfactorbyrelaxationoscillationfrequencyinalaserwithopticalfeedback AT yuyanguang measuringlinewidthenhancementfactorbyrelaxationoscillationfrequencyinalaserwithopticalfeedback AT xijiangtao measuringlinewidthenhancementfactorbyrelaxationoscillationfrequencyinalaserwithopticalfeedback AT guoqinghua measuringlinewidthenhancementfactorbyrelaxationoscillationfrequencyinalaserwithopticalfeedback AT tongjun measuringlinewidthenhancementfactorbyrelaxationoscillationfrequencyinalaserwithopticalfeedback |