Cargando…

Motion Synchronous Composite Decoupling with Fewer Sensors on Multichannel Hydraulic Force Control for Aircraft Structural Loading Test System

The aircraft full-scale fatigue test is widely used in the modern aircraft industry for the safety of flight. Generally, the aircraft full-scale fatigue test is achieved by structural loading; multiple hydraulic actuators are used to apply load for force control. The fatigue loading test takes appro...

Descripción completa

Detalles Bibliográficos
Autores principales: Shang, Yaoxing, Bai, Ning, Jiao, Lingzhi, Yao, Nan, Wu, Shuai, Jiao, Zongxia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6264048/
https://www.ncbi.nlm.nih.gov/pubmed/30463356
http://dx.doi.org/10.3390/s18114050
_version_ 1783375406339981312
author Shang, Yaoxing
Bai, Ning
Jiao, Lingzhi
Yao, Nan
Wu, Shuai
Jiao, Zongxia
author_facet Shang, Yaoxing
Bai, Ning
Jiao, Lingzhi
Yao, Nan
Wu, Shuai
Jiao, Zongxia
author_sort Shang, Yaoxing
collection PubMed
description The aircraft full-scale fatigue test is widely used in the modern aircraft industry for the safety of flight. Generally, the aircraft full-scale fatigue test is achieved by structural loading; multiple hydraulic actuators are used to apply load for force control. The fatigue loading test takes approximately several years. A key challenge is how to accelerate the loading frequency to shorten the total test time. Nevertheless, when pluralities of hydraulic actuator simultaneously increase the loading frequency, the mutual coupling force from the low rigidity of the aircraft structure will cause a large loading error, meaning that the test cannot be implemented. Although it is possible to reduce error by adding sensors, the force sensors need to connect several kilometers of cable. This paper proposed a novel motion synchronous composite decoupling control strategy with fewer sensors. The control method compensates the negative coupling effect of the channels by integrating the command signals and feedback signals of all channels. It can suppress coupling force and reduce errors at higher frequencies, thereby shortening the experiment time. Opposed to traditional decoupling control methods, advantages of this strategy are that it only needs force sensors and it does not need additional displacement or velocity and acceleration sensors to collect state variables for building the state space. Furthermore, it has been experimentally verified that the new motion synchronous composite decoupling control method can indeed guarantee sufficient control accuracy when the test frequency is increased. The method has great economic significance for shortening test duration.
format Online
Article
Text
id pubmed-6264048
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-62640482018-12-12 Motion Synchronous Composite Decoupling with Fewer Sensors on Multichannel Hydraulic Force Control for Aircraft Structural Loading Test System Shang, Yaoxing Bai, Ning Jiao, Lingzhi Yao, Nan Wu, Shuai Jiao, Zongxia Sensors (Basel) Article The aircraft full-scale fatigue test is widely used in the modern aircraft industry for the safety of flight. Generally, the aircraft full-scale fatigue test is achieved by structural loading; multiple hydraulic actuators are used to apply load for force control. The fatigue loading test takes approximately several years. A key challenge is how to accelerate the loading frequency to shorten the total test time. Nevertheless, when pluralities of hydraulic actuator simultaneously increase the loading frequency, the mutual coupling force from the low rigidity of the aircraft structure will cause a large loading error, meaning that the test cannot be implemented. Although it is possible to reduce error by adding sensors, the force sensors need to connect several kilometers of cable. This paper proposed a novel motion synchronous composite decoupling control strategy with fewer sensors. The control method compensates the negative coupling effect of the channels by integrating the command signals and feedback signals of all channels. It can suppress coupling force and reduce errors at higher frequencies, thereby shortening the experiment time. Opposed to traditional decoupling control methods, advantages of this strategy are that it only needs force sensors and it does not need additional displacement or velocity and acceleration sensors to collect state variables for building the state space. Furthermore, it has been experimentally verified that the new motion synchronous composite decoupling control method can indeed guarantee sufficient control accuracy when the test frequency is increased. The method has great economic significance for shortening test duration. MDPI 2018-11-20 /pmc/articles/PMC6264048/ /pubmed/30463356 http://dx.doi.org/10.3390/s18114050 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shang, Yaoxing
Bai, Ning
Jiao, Lingzhi
Yao, Nan
Wu, Shuai
Jiao, Zongxia
Motion Synchronous Composite Decoupling with Fewer Sensors on Multichannel Hydraulic Force Control for Aircraft Structural Loading Test System
title Motion Synchronous Composite Decoupling with Fewer Sensors on Multichannel Hydraulic Force Control for Aircraft Structural Loading Test System
title_full Motion Synchronous Composite Decoupling with Fewer Sensors on Multichannel Hydraulic Force Control for Aircraft Structural Loading Test System
title_fullStr Motion Synchronous Composite Decoupling with Fewer Sensors on Multichannel Hydraulic Force Control for Aircraft Structural Loading Test System
title_full_unstemmed Motion Synchronous Composite Decoupling with Fewer Sensors on Multichannel Hydraulic Force Control for Aircraft Structural Loading Test System
title_short Motion Synchronous Composite Decoupling with Fewer Sensors on Multichannel Hydraulic Force Control for Aircraft Structural Loading Test System
title_sort motion synchronous composite decoupling with fewer sensors on multichannel hydraulic force control for aircraft structural loading test system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6264048/
https://www.ncbi.nlm.nih.gov/pubmed/30463356
http://dx.doi.org/10.3390/s18114050
work_keys_str_mv AT shangyaoxing motionsynchronouscompositedecouplingwithfewersensorsonmultichannelhydraulicforcecontrolforaircraftstructuralloadingtestsystem
AT baining motionsynchronouscompositedecouplingwithfewersensorsonmultichannelhydraulicforcecontrolforaircraftstructuralloadingtestsystem
AT jiaolingzhi motionsynchronouscompositedecouplingwithfewersensorsonmultichannelhydraulicforcecontrolforaircraftstructuralloadingtestsystem
AT yaonan motionsynchronouscompositedecouplingwithfewersensorsonmultichannelhydraulicforcecontrolforaircraftstructuralloadingtestsystem
AT wushuai motionsynchronouscompositedecouplingwithfewersensorsonmultichannelhydraulicforcecontrolforaircraftstructuralloadingtestsystem
AT jiaozongxia motionsynchronouscompositedecouplingwithfewersensorsonmultichannelhydraulicforcecontrolforaircraftstructuralloadingtestsystem