Quantification of DNA by a Thermal-Durable Biosensor Modified with Conductive Poly(3,4-ethylenedioxythiophene)
The general clinical procedure for viral DNA detection or gene mutation diagnosis following polymerase chain reaction (PCR) often involves gel electrophoresis and DNA sequencing, which is usually time-consuming. In this study, we have proposed a facile strategy to construct a DNA biosensor, in which...
Autores principales: | Gu, Yesong, Tseng, Po-Yuan, Bi, Xiang, Yang, Jason H. C. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6264125/ https://www.ncbi.nlm.nih.gov/pubmed/30380711 http://dx.doi.org/10.3390/s18113684 |
Ejemplares similares
-
A Novel Conductive Poly(3,4-ethylenedioxythiophene)-BSA Film for the Construction of a Durable HRP Biosensor Modified with NanoAu Particles
por: Xu, Fangcheng, et al.
Publicado: (2016) -
Modifying the conductive properties of poly(3,4-ethylenedioxythiophene) thin films in green solvents
por: Hou, Bin, et al.
Publicado: (2022) -
Progress in Synthesis of Conductive Polymer Poly(3,4-Ethylenedioxythiophene)
por: Nie, Shisong, et al.
Publicado: (2021) -
Fabrication of an Extremely Cheap Poly(3,4-ethylenedioxythiophene) Modified Pencil Lead Electrode for Effective Hydroquinone Sensing
por: Lu, Jian-Yu, et al.
Publicado: (2021) -
Thermal conductivity of poly(3,4-ethylenedioxythiophene) films engineered by oxidative chemical vapor deposition (oCVD)
por: Smith, Phil M., et al.
Publicado: (2018)