PURPOSE: To assess the usefulness of spectral-domain optical coherence tomography (SD-OCT) peripapillary retinal nerve fiber layer (RNFL) thickness measurement in discriminating early phase optic disc edema (ODE) from pseudoedema (PODE). METHODS: Hospital-based, multicenter, cross-sectional study in...

Descripción completa

Detalles Bibliográficos
Autores principales: Carta, Arturo, Mora, Paolo, Aldigeri, Raffaella, Gozzi, Fabrizio, Favilla, Stefania, Tedesco, Salvatore, Calzetti, Giacomo, Farci, Roberta, Barboni, Piero, Bianchi-Marzoli, Stefania, Fossarello, Maurizio, Gandolfi, Stefano, Sadun, Alfredo A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6264818/
https://www.ncbi.nlm.nih.gov/pubmed/30496251
http://dx.doi.org/10.1371/journal.pone.0208145
_version_ 1783375571877625856
author Carta, Arturo
Mora, Paolo
Aldigeri, Raffaella
Gozzi, Fabrizio
Favilla, Stefania
Tedesco, Salvatore
Calzetti, Giacomo
Farci, Roberta
Barboni, Piero
Bianchi-Marzoli, Stefania
Fossarello, Maurizio
Gandolfi, Stefano
Sadun, Alfredo A.
author_facet Carta, Arturo
Mora, Paolo
Aldigeri, Raffaella
Gozzi, Fabrizio
Favilla, Stefania
Tedesco, Salvatore
Calzetti, Giacomo
Farci, Roberta
Barboni, Piero
Bianchi-Marzoli, Stefania
Fossarello, Maurizio
Gandolfi, Stefano
Sadun, Alfredo A.
author_sort Carta, Arturo
collection PubMed
description PURPOSE: To assess the usefulness of spectral-domain optical coherence tomography (SD-OCT) peripapillary retinal nerve fiber layer (RNFL) thickness measurement in discriminating early phase optic disc edema (ODE) from pseudoedema (PODE). METHODS: Hospital-based, multicenter, cross-sectional study involving external patients referred for recent identification of “presumed ODE”. Patients underwent SD-OCT optic nerve head (ONH) RNFL thickness measurement at their first evaluation. In 155 of these, the causative etiology was subsequently ascertained and the respective eyes (one per patient) were assigned to the ODE (95 eyes) or PODE (60 eyes) group. Admission SD-OCT data were retrieved and used for the analysis. ROC curve analysis was used to calculate specificity, sensitivity and predictive value (PV) of the RNFL values. RESULTS: The PODE group was significantly younger than the ODE group (p = 0.007). The average and any single-quadrant RNFL thickness was significantly higher in the ODE group compared with the PODE and control groups. The average and the inferior quadrant thicknesses tested the most powerful parameters to differentiate ODE from PODE. A cutoff value of ≥ 110 μm for the average area, or of ≥ 150 μm for the inferior quadrant was associated with maximal sensitivity and specificity with positive PV greater than 80%. CONCLUSIONS: The SD-OCT evaluation of the peripapillary RNFL achieved good specificity, sensitivity and positive PV in discriminating between ODE and PODE. Despite the correct differential diagnosis between these categories still relies on a careful medical history taking and other ancillary testing, we proved the usefulness of SD-OCT RNFL measurement in supporting the diagnostic process.
format Online
Article
Text
id pubmed-6264818
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-62648182018-12-19 Optical coherence tomography is a useful tool in the differentiation between true edema and pseudoedema of the optic disc Carta, Arturo Mora, Paolo Aldigeri, Raffaella Gozzi, Fabrizio Favilla, Stefania Tedesco, Salvatore Calzetti, Giacomo Farci, Roberta Barboni, Piero Bianchi-Marzoli, Stefania Fossarello, Maurizio Gandolfi, Stefano Sadun, Alfredo A. PLoS One Research Article PURPOSE: To assess the usefulness of spectral-domain optical coherence tomography (SD-OCT) peripapillary retinal nerve fiber layer (RNFL) thickness measurement in discriminating early phase optic disc edema (ODE) from pseudoedema (PODE). METHODS: Hospital-based, multicenter, cross-sectional study involving external patients referred for recent identification of “presumed ODE”. Patients underwent SD-OCT optic nerve head (ONH) RNFL thickness measurement at their first evaluation. In 155 of these, the causative etiology was subsequently ascertained and the respective eyes (one per patient) were assigned to the ODE (95 eyes) or PODE (60 eyes) group. Admission SD-OCT data were retrieved and used for the analysis. ROC curve analysis was used to calculate specificity, sensitivity and predictive value (PV) of the RNFL values. RESULTS: The PODE group was significantly younger than the ODE group (p = 0.007). The average and any single-quadrant RNFL thickness was significantly higher in the ODE group compared with the PODE and control groups. The average and the inferior quadrant thicknesses tested the most powerful parameters to differentiate ODE from PODE. A cutoff value of ≥ 110 μm for the average area, or of ≥ 150 μm for the inferior quadrant was associated with maximal sensitivity and specificity with positive PV greater than 80%. CONCLUSIONS: The SD-OCT evaluation of the peripapillary RNFL achieved good specificity, sensitivity and positive PV in discriminating between ODE and PODE. Despite the correct differential diagnosis between these categories still relies on a careful medical history taking and other ancillary testing, we proved the usefulness of SD-OCT RNFL measurement in supporting the diagnostic process. Public Library of Science 2018-11-29 /pmc/articles/PMC6264818/ /pubmed/30496251 http://dx.doi.org/10.1371/journal.pone.0208145 Text en © 2018 Carta et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Carta, Arturo
Mora, Paolo
Aldigeri, Raffaella
Gozzi, Fabrizio
Favilla, Stefania
Tedesco, Salvatore
Calzetti, Giacomo
Farci, Roberta
Barboni, Piero
Bianchi-Marzoli, Stefania
Fossarello, Maurizio
Gandolfi, Stefano
Sadun, Alfredo A.
Optical coherence tomography is a useful tool in the differentiation between true edema and pseudoedema of the optic disc
title Optical coherence tomography is a useful tool in the differentiation between true edema and pseudoedema of the optic disc
title_full Optical coherence tomography is a useful tool in the differentiation between true edema and pseudoedema of the optic disc
title_fullStr Optical coherence tomography is a useful tool in the differentiation between true edema and pseudoedema of the optic disc
title_full_unstemmed Optical coherence tomography is a useful tool in the differentiation between true edema and pseudoedema of the optic disc
title_short Optical coherence tomography is a useful tool in the differentiation between true edema and pseudoedema of the optic disc
title_sort optical coherence tomography is a useful tool in the differentiation between true edema and pseudoedema of the optic disc
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6264818/
https://www.ncbi.nlm.nih.gov/pubmed/30496251
http://dx.doi.org/10.1371/journal.pone.0208145
work_keys_str_mv AT cartaarturo opticalcoherencetomographyisausefultoolinthedifferentiationbetweentrueedemaandpseudoedemaoftheopticdisc
AT morapaolo opticalcoherencetomographyisausefultoolinthedifferentiationbetweentrueedemaandpseudoedemaoftheopticdisc
AT aldigeriraffaella opticalcoherencetomographyisausefultoolinthedifferentiationbetweentrueedemaandpseudoedemaoftheopticdisc
AT gozzifabrizio opticalcoherencetomographyisausefultoolinthedifferentiationbetweentrueedemaandpseudoedemaoftheopticdisc
AT favillastefania opticalcoherencetomographyisausefultoolinthedifferentiationbetweentrueedemaandpseudoedemaoftheopticdisc
AT tedescosalvatore opticalcoherencetomographyisausefultoolinthedifferentiationbetweentrueedemaandpseudoedemaoftheopticdisc
AT calzettigiacomo opticalcoherencetomographyisausefultoolinthedifferentiationbetweentrueedemaandpseudoedemaoftheopticdisc
AT farciroberta opticalcoherencetomographyisausefultoolinthedifferentiationbetweentrueedemaandpseudoedemaoftheopticdisc
AT barbonipiero opticalcoherencetomographyisausefultoolinthedifferentiationbetweentrueedemaandpseudoedemaoftheopticdisc
AT bianchimarzolistefania opticalcoherencetomographyisausefultoolinthedifferentiationbetweentrueedemaandpseudoedemaoftheopticdisc
AT fossarellomaurizio opticalcoherencetomographyisausefultoolinthedifferentiationbetweentrueedemaandpseudoedemaoftheopticdisc
AT gandolfistefano opticalcoherencetomographyisausefultoolinthedifferentiationbetweentrueedemaandpseudoedemaoftheopticdisc
AT sadunalfredoa opticalcoherencetomographyisausefultoolinthedifferentiationbetweentrueedemaandpseudoedemaoftheopticdisc