Cargando…
Calibration of a Constitutive Model from Tension and Nanoindentation for Lead-Free Solder
It is challenging to evaluate constitutive behaviour by using conventional uniaxial tests for materials with limited sizes, considering the miniaturization trend of integrated circuits in electronic devices. An instrumented nanoindentation approach is appealing to obtain local properties as the func...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6266157/ https://www.ncbi.nlm.nih.gov/pubmed/30463308 http://dx.doi.org/10.3390/mi9110608 |
_version_ | 1783375775166103552 |
---|---|
author | Long, Xu Zhang, Xiaodi Tang, Wenbin Wang, Shaobin Feng, Yihui Chang, Chao |
author_facet | Long, Xu Zhang, Xiaodi Tang, Wenbin Wang, Shaobin Feng, Yihui Chang, Chao |
author_sort | Long, Xu |
collection | PubMed |
description | It is challenging to evaluate constitutive behaviour by using conventional uniaxial tests for materials with limited sizes, considering the miniaturization trend of integrated circuits in electronic devices. An instrumented nanoindentation approach is appealing to obtain local properties as the function of penetration depth. In this paper, both conventional tensile and nanoindentation experiments are performed on samples of a lead-free Sn–3.0Ag–0.5Cu (SAC305) solder alloy. In order to align the material behaviour, thermal treatments were performed at different temperatures and durations for all specimens, for both tensile experiments and nanoindentation experiments. Based on the self-similarity of the used Berkovich indenter, a power-law model is adopted to describe the stress–strain relationship by means of analytical dimensionless analysis on the applied load-penetration depth responses from nanoindentation experiments. In light of the significant difference of applied strain rates in the tensile and nanoindentation experiments, two “rate factors” are proposed by multiplying the representative stress and stress exponent in the adopted analytical model, and the corresponding values are determined for the best predictions of nanoindentation responses in the form of an applied load–indentation depth relationship. Eventually, good agreement is achieved when comparing the stress–strain responses measured from tensile experiments and estimated from the applied load–indentation depth responses of nanoindentation experiments. The rate factors [Formula: see text] and [Formula: see text] are calibrated to be about 0.52 and 0.10, respectively, which facilitate the conversion of constitutive behaviour from nanoindentation experiments for material sample with a limited size. |
format | Online Article Text |
id | pubmed-6266157 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-62661572018-12-06 Calibration of a Constitutive Model from Tension and Nanoindentation for Lead-Free Solder Long, Xu Zhang, Xiaodi Tang, Wenbin Wang, Shaobin Feng, Yihui Chang, Chao Micromachines (Basel) Article It is challenging to evaluate constitutive behaviour by using conventional uniaxial tests for materials with limited sizes, considering the miniaturization trend of integrated circuits in electronic devices. An instrumented nanoindentation approach is appealing to obtain local properties as the function of penetration depth. In this paper, both conventional tensile and nanoindentation experiments are performed on samples of a lead-free Sn–3.0Ag–0.5Cu (SAC305) solder alloy. In order to align the material behaviour, thermal treatments were performed at different temperatures and durations for all specimens, for both tensile experiments and nanoindentation experiments. Based on the self-similarity of the used Berkovich indenter, a power-law model is adopted to describe the stress–strain relationship by means of analytical dimensionless analysis on the applied load-penetration depth responses from nanoindentation experiments. In light of the significant difference of applied strain rates in the tensile and nanoindentation experiments, two “rate factors” are proposed by multiplying the representative stress and stress exponent in the adopted analytical model, and the corresponding values are determined for the best predictions of nanoindentation responses in the form of an applied load–indentation depth relationship. Eventually, good agreement is achieved when comparing the stress–strain responses measured from tensile experiments and estimated from the applied load–indentation depth responses of nanoindentation experiments. The rate factors [Formula: see text] and [Formula: see text] are calibrated to be about 0.52 and 0.10, respectively, which facilitate the conversion of constitutive behaviour from nanoindentation experiments for material sample with a limited size. MDPI 2018-11-20 /pmc/articles/PMC6266157/ /pubmed/30463308 http://dx.doi.org/10.3390/mi9110608 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Long, Xu Zhang, Xiaodi Tang, Wenbin Wang, Shaobin Feng, Yihui Chang, Chao Calibration of a Constitutive Model from Tension and Nanoindentation for Lead-Free Solder |
title | Calibration of a Constitutive Model from Tension and Nanoindentation for Lead-Free Solder |
title_full | Calibration of a Constitutive Model from Tension and Nanoindentation for Lead-Free Solder |
title_fullStr | Calibration of a Constitutive Model from Tension and Nanoindentation for Lead-Free Solder |
title_full_unstemmed | Calibration of a Constitutive Model from Tension and Nanoindentation for Lead-Free Solder |
title_short | Calibration of a Constitutive Model from Tension and Nanoindentation for Lead-Free Solder |
title_sort | calibration of a constitutive model from tension and nanoindentation for lead-free solder |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6266157/ https://www.ncbi.nlm.nih.gov/pubmed/30463308 http://dx.doi.org/10.3390/mi9110608 |
work_keys_str_mv | AT longxu calibrationofaconstitutivemodelfromtensionandnanoindentationforleadfreesolder AT zhangxiaodi calibrationofaconstitutivemodelfromtensionandnanoindentationforleadfreesolder AT tangwenbin calibrationofaconstitutivemodelfromtensionandnanoindentationforleadfreesolder AT wangshaobin calibrationofaconstitutivemodelfromtensionandnanoindentationforleadfreesolder AT fengyihui calibrationofaconstitutivemodelfromtensionandnanoindentationforleadfreesolder AT changchao calibrationofaconstitutivemodelfromtensionandnanoindentationforleadfreesolder |