Cargando…
A Study on An EMG Sensor with High Gain and Low Noise for Measuring Human Muscular Movement Patterns for Smart Healthcare
The form of the collection of bio-signals is becoming increasingly integrated and smart to meet the demands of the age of smart healthcare and the Fourth Industrial Revolution. In addition, the movement patterns of human muscles are also becoming more complex due to diversification of the human livi...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6266180/ https://www.ncbi.nlm.nih.gov/pubmed/30715054 http://dx.doi.org/10.3390/mi9110555 |
_version_ | 1783375780509646848 |
---|---|
author | Yuk, Sun-Woo Hwang, In-Ho Cho, Hyeon-Rae Park, Sang-Geon |
author_facet | Yuk, Sun-Woo Hwang, In-Ho Cho, Hyeon-Rae Park, Sang-Geon |
author_sort | Yuk, Sun-Woo |
collection | PubMed |
description | The form of the collection of bio-signals is becoming increasingly integrated and smart to meet the demands of the age of smart healthcare and the Fourth Industrial Revolution. In addition, the movement patterns of human muscles are also becoming more complex due to diversification of the human living environment. An analysis of the movement patterns of normal people’s muscles contracting with age and that of patients who are being treated in a hospital, including the disabled, will help improve life patterns, medical treatment patterns, and quality of life. In this study, the researchers developed a smart electromyogram (EMG) sensor which can improve human life patterns through EMG range and pattern recognition, which is beyond the conventional simple EMG measurement level. The developed sensor has a high gain of 10,000 times or more, noise of 500 uVrms or less, and common mode rejection ratio (CMRR) of 100 dB or more for EMG level and pattern recognition. The pattern recognition time of the sensor is 30 s. All the circuits developed in this study have a phase margin of 75 degrees or more for stability. Standard 0.25 μm complementary metal oxide semiconductor (CMOS) technology was used for the integrated circuit design. The system error rate was confirmed to be 1% or less through a clinical trial conducted on five males in their 40s and three females in their 30s for the past two years. The muscle activities of all subjects of the clinical trial were improved by about 21% by changing their life patterns based on EMG pattern recognition. |
format | Online Article Text |
id | pubmed-6266180 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-62661802018-12-06 A Study on An EMG Sensor with High Gain and Low Noise for Measuring Human Muscular Movement Patterns for Smart Healthcare Yuk, Sun-Woo Hwang, In-Ho Cho, Hyeon-Rae Park, Sang-Geon Micromachines (Basel) Article The form of the collection of bio-signals is becoming increasingly integrated and smart to meet the demands of the age of smart healthcare and the Fourth Industrial Revolution. In addition, the movement patterns of human muscles are also becoming more complex due to diversification of the human living environment. An analysis of the movement patterns of normal people’s muscles contracting with age and that of patients who are being treated in a hospital, including the disabled, will help improve life patterns, medical treatment patterns, and quality of life. In this study, the researchers developed a smart electromyogram (EMG) sensor which can improve human life patterns through EMG range and pattern recognition, which is beyond the conventional simple EMG measurement level. The developed sensor has a high gain of 10,000 times or more, noise of 500 uVrms or less, and common mode rejection ratio (CMRR) of 100 dB or more for EMG level and pattern recognition. The pattern recognition time of the sensor is 30 s. All the circuits developed in this study have a phase margin of 75 degrees or more for stability. Standard 0.25 μm complementary metal oxide semiconductor (CMOS) technology was used for the integrated circuit design. The system error rate was confirmed to be 1% or less through a clinical trial conducted on five males in their 40s and three females in their 30s for the past two years. The muscle activities of all subjects of the clinical trial were improved by about 21% by changing their life patterns based on EMG pattern recognition. MDPI 2018-10-29 /pmc/articles/PMC6266180/ /pubmed/30715054 http://dx.doi.org/10.3390/mi9110555 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Yuk, Sun-Woo Hwang, In-Ho Cho, Hyeon-Rae Park, Sang-Geon A Study on An EMG Sensor with High Gain and Low Noise for Measuring Human Muscular Movement Patterns for Smart Healthcare |
title | A Study on An EMG Sensor with High Gain and Low Noise for Measuring Human Muscular Movement Patterns for Smart Healthcare |
title_full | A Study on An EMG Sensor with High Gain and Low Noise for Measuring Human Muscular Movement Patterns for Smart Healthcare |
title_fullStr | A Study on An EMG Sensor with High Gain and Low Noise for Measuring Human Muscular Movement Patterns for Smart Healthcare |
title_full_unstemmed | A Study on An EMG Sensor with High Gain and Low Noise for Measuring Human Muscular Movement Patterns for Smart Healthcare |
title_short | A Study on An EMG Sensor with High Gain and Low Noise for Measuring Human Muscular Movement Patterns for Smart Healthcare |
title_sort | study on an emg sensor with high gain and low noise for measuring human muscular movement patterns for smart healthcare |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6266180/ https://www.ncbi.nlm.nih.gov/pubmed/30715054 http://dx.doi.org/10.3390/mi9110555 |
work_keys_str_mv | AT yuksunwoo astudyonanemgsensorwithhighgainandlownoiseformeasuringhumanmuscularmovementpatternsforsmarthealthcare AT hwanginho astudyonanemgsensorwithhighgainandlownoiseformeasuringhumanmuscularmovementpatternsforsmarthealthcare AT chohyeonrae astudyonanemgsensorwithhighgainandlownoiseformeasuringhumanmuscularmovementpatternsforsmarthealthcare AT parksanggeon astudyonanemgsensorwithhighgainandlownoiseformeasuringhumanmuscularmovementpatternsforsmarthealthcare AT yuksunwoo studyonanemgsensorwithhighgainandlownoiseformeasuringhumanmuscularmovementpatternsforsmarthealthcare AT hwanginho studyonanemgsensorwithhighgainandlownoiseformeasuringhumanmuscularmovementpatternsforsmarthealthcare AT chohyeonrae studyonanemgsensorwithhighgainandlownoiseformeasuringhumanmuscularmovementpatternsforsmarthealthcare AT parksanggeon studyonanemgsensorwithhighgainandlownoiseformeasuringhumanmuscularmovementpatternsforsmarthealthcare |