Cargando…

Scotoma Simulation in Healthy Subjects

SIGNIFICANCE: This article shows a successful concept for simulating central scotoma, which is associated with age-related macular degeneration (AMD), in healthy subjects by an induced dark spot at the retina using occlusive contact lenses. The new concept includes a control mechanism to adjust the...

Descripción completa

Detalles Bibliográficos
Autores principales: Klee, Sascha, Link, Dietmar, Sinzinger, Stefan, Haueisen, Jens
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6266299/
https://www.ncbi.nlm.nih.gov/pubmed/30451808
http://dx.doi.org/10.1097/OPX.0000000000001310
_version_ 1783375807382552576
author Klee, Sascha
Link, Dietmar
Sinzinger, Stefan
Haueisen, Jens
author_facet Klee, Sascha
Link, Dietmar
Sinzinger, Stefan
Haueisen, Jens
author_sort Klee, Sascha
collection PubMed
description SIGNIFICANCE: This article shows a successful concept for simulating central scotoma, which is associated with age-related macular degeneration (AMD), in healthy subjects by an induced dark spot at the retina using occlusive contact lenses. The new concept includes a control mechanism to adjust the scotoma size through controlling pupil size without medication. Therefore, a miniaturized full-field adaptation device was used. PURPOSE: The aim of this study was to design a novel concept to simulate AMD scotoma in healthy subjects using occlusive contact lenses. METHODS: To define an optimal set of lens parameters, we constructed an optical model and considered both the anatomical pupil diameter and the opaque central zone diameter of the contact lens. To adjust the scotoma size, we built a miniaturized full-field adaptation device. We demonstrate the validity of this novel concept by functional measurements of visual fields using automated threshold perimetry. Finally, we conducted a perception study including two tasks, consisting of pictograms and letters. The stimuli were presented at different eccentricities and magnifications. RESULTS: The visual fields of all 10 volunteers exhibited absolute scotomas. The loss of contrast sensitivity ranged within 27 and 36 dB (P < .05), and the scotoma localizations were nearly centered to the macula (mean variation, 2.0 ± 4.8° horizontally; 3.5 ± 4.7° vertically). The eccentric perception of letters showed the largest numbers of correctly identified stimuli. The perception of pictograms showed significantly reduced numbers (P < .0001) and revealed a dependency on magnification. The results suggest that best perception is possible for magnified stimuli near the scotoma. CONCLUSIONS: We demonstrated that the creation of an absolute simulated AMD scotoma is possible using occlusive contact lenses combined with a miniaturized full-field adaptation device.
format Online
Article
Text
id pubmed-6266299
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-62662992019-03-06 Scotoma Simulation in Healthy Subjects Klee, Sascha Link, Dietmar Sinzinger, Stefan Haueisen, Jens Optom Vis Sci Original Investigations SIGNIFICANCE: This article shows a successful concept for simulating central scotoma, which is associated with age-related macular degeneration (AMD), in healthy subjects by an induced dark spot at the retina using occlusive contact lenses. The new concept includes a control mechanism to adjust the scotoma size through controlling pupil size without medication. Therefore, a miniaturized full-field adaptation device was used. PURPOSE: The aim of this study was to design a novel concept to simulate AMD scotoma in healthy subjects using occlusive contact lenses. METHODS: To define an optimal set of lens parameters, we constructed an optical model and considered both the anatomical pupil diameter and the opaque central zone diameter of the contact lens. To adjust the scotoma size, we built a miniaturized full-field adaptation device. We demonstrate the validity of this novel concept by functional measurements of visual fields using automated threshold perimetry. Finally, we conducted a perception study including two tasks, consisting of pictograms and letters. The stimuli were presented at different eccentricities and magnifications. RESULTS: The visual fields of all 10 volunteers exhibited absolute scotomas. The loss of contrast sensitivity ranged within 27 and 36 dB (P < .05), and the scotoma localizations were nearly centered to the macula (mean variation, 2.0 ± 4.8° horizontally; 3.5 ± 4.7° vertically). The eccentric perception of letters showed the largest numbers of correctly identified stimuli. The perception of pictograms showed significantly reduced numbers (P < .0001) and revealed a dependency on magnification. The results suggest that best perception is possible for magnified stimuli near the scotoma. CONCLUSIONS: We demonstrated that the creation of an absolute simulated AMD scotoma is possible using occlusive contact lenses combined with a miniaturized full-field adaptation device. Lippincott Williams & Wilkins 2018-12 2018-11-16 /pmc/articles/PMC6266299/ /pubmed/30451808 http://dx.doi.org/10.1097/OPX.0000000000001310 Text en Copyright © 2018 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Optometry. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Original Investigations
Klee, Sascha
Link, Dietmar
Sinzinger, Stefan
Haueisen, Jens
Scotoma Simulation in Healthy Subjects
title Scotoma Simulation in Healthy Subjects
title_full Scotoma Simulation in Healthy Subjects
title_fullStr Scotoma Simulation in Healthy Subjects
title_full_unstemmed Scotoma Simulation in Healthy Subjects
title_short Scotoma Simulation in Healthy Subjects
title_sort scotoma simulation in healthy subjects
topic Original Investigations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6266299/
https://www.ncbi.nlm.nih.gov/pubmed/30451808
http://dx.doi.org/10.1097/OPX.0000000000001310
work_keys_str_mv AT kleesascha scotomasimulationinhealthysubjects
AT linkdietmar scotomasimulationinhealthysubjects
AT sinzingerstefan scotomasimulationinhealthysubjects
AT haueisenjens scotomasimulationinhealthysubjects