Monolithic Wafer Scale Integration of Silicon Nanoribbon Sensors with CMOS for Lab-on-Chip Application

Silicon ribbons (SiRi) have been well-established as highly sensitive transducers for biosensing applications thanks to their high surface to volume ratio. However, selective and multiplexed detection of biomarkers remains a challenge. Further, very few attempts have been made to integrate SiRi with...

Descripción completa

Detalles Bibliográficos
Autores principales: Jayakumar, Ganesh, Hellström, Per-Erik, Östling, Mikael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6266487/
https://www.ncbi.nlm.nih.gov/pubmed/30715043
http://dx.doi.org/10.3390/mi9110544
_version_ 1783375850389897216
author Jayakumar, Ganesh
Hellström, Per-Erik
Östling, Mikael
author_facet Jayakumar, Ganesh
Hellström, Per-Erik
Östling, Mikael
author_sort Jayakumar, Ganesh
collection PubMed
description Silicon ribbons (SiRi) have been well-established as highly sensitive transducers for biosensing applications thanks to their high surface to volume ratio. However, selective and multiplexed detection of biomarkers remains a challenge. Further, very few attempts have been made to integrate SiRi with complementary-metal-oxide-semiconductor (CMOS) circuits to form a complete lab-on-chip (LOC). Integration of SiRi with CMOS will facilitate real time detection of the output signal and provide a compact small sized LOC. Here, we propose a novel pixel based SiRi device monolithically integrated with CMOS field-effect-transistors (FET) for real-time selective multiplexed detection. The SiRi pixels are fabricated on a silicon-on-insulator wafer using a top-down method. Each pixel houses a control FET, fluid-gate (FG) and SiRi sensor. The pixel is controlled by simultaneously applying frontgate (V(G)) and backgate voltage (V(BG)). The liquid potential can be monitored using the FG. We report the transfer characteristics (I(D)-V(G)) of N- and P-type SiRi pixels. Further, the I(D)-V(G) characteristics of the SiRis are studied at different V(BG). The application of V(BG) to turn ON the SiRi modulates the subthreshold slope (SS) and threshold voltage (V(TH)) of the control FET. Particularly, N-type pixels cannot be turned OFF due to the control NFET operating in the strong inversion regime. This is due to large V(BG) (≥25 V) application to turn ON the SiRi sensor. Conversely, the P-type SiRi sensors do not require large V(BG) to switch ON. Thus, P-type pixels exhibit excellent I(ON)/I(OFF) ≥ 10(6), SS of 70–80 mV/dec and V(TH) of 0.5 V. These promising results will empower the large-scale cost-efficient production of SiRi based LOC sensors.
format Online
Article
Text
id pubmed-6266487
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-62664872018-12-06 Monolithic Wafer Scale Integration of Silicon Nanoribbon Sensors with CMOS for Lab-on-Chip Application Jayakumar, Ganesh Hellström, Per-Erik Östling, Mikael Micromachines (Basel) Article Silicon ribbons (SiRi) have been well-established as highly sensitive transducers for biosensing applications thanks to their high surface to volume ratio. However, selective and multiplexed detection of biomarkers remains a challenge. Further, very few attempts have been made to integrate SiRi with complementary-metal-oxide-semiconductor (CMOS) circuits to form a complete lab-on-chip (LOC). Integration of SiRi with CMOS will facilitate real time detection of the output signal and provide a compact small sized LOC. Here, we propose a novel pixel based SiRi device monolithically integrated with CMOS field-effect-transistors (FET) for real-time selective multiplexed detection. The SiRi pixels are fabricated on a silicon-on-insulator wafer using a top-down method. Each pixel houses a control FET, fluid-gate (FG) and SiRi sensor. The pixel is controlled by simultaneously applying frontgate (V(G)) and backgate voltage (V(BG)). The liquid potential can be monitored using the FG. We report the transfer characteristics (I(D)-V(G)) of N- and P-type SiRi pixels. Further, the I(D)-V(G) characteristics of the SiRis are studied at different V(BG). The application of V(BG) to turn ON the SiRi modulates the subthreshold slope (SS) and threshold voltage (V(TH)) of the control FET. Particularly, N-type pixels cannot be turned OFF due to the control NFET operating in the strong inversion regime. This is due to large V(BG) (≥25 V) application to turn ON the SiRi sensor. Conversely, the P-type SiRi sensors do not require large V(BG) to switch ON. Thus, P-type pixels exhibit excellent I(ON)/I(OFF) ≥ 10(6), SS of 70–80 mV/dec and V(TH) of 0.5 V. These promising results will empower the large-scale cost-efficient production of SiRi based LOC sensors. MDPI 2018-10-25 /pmc/articles/PMC6266487/ /pubmed/30715043 http://dx.doi.org/10.3390/mi9110544 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jayakumar, Ganesh
Hellström, Per-Erik
Östling, Mikael
Monolithic Wafer Scale Integration of Silicon Nanoribbon Sensors with CMOS for Lab-on-Chip Application
title Monolithic Wafer Scale Integration of Silicon Nanoribbon Sensors with CMOS for Lab-on-Chip Application
title_full Monolithic Wafer Scale Integration of Silicon Nanoribbon Sensors with CMOS for Lab-on-Chip Application
title_fullStr Monolithic Wafer Scale Integration of Silicon Nanoribbon Sensors with CMOS for Lab-on-Chip Application
title_full_unstemmed Monolithic Wafer Scale Integration of Silicon Nanoribbon Sensors with CMOS for Lab-on-Chip Application
title_short Monolithic Wafer Scale Integration of Silicon Nanoribbon Sensors with CMOS for Lab-on-Chip Application
title_sort monolithic wafer scale integration of silicon nanoribbon sensors with cmos for lab-on-chip application
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6266487/
https://www.ncbi.nlm.nih.gov/pubmed/30715043
http://dx.doi.org/10.3390/mi9110544
work_keys_str_mv AT jayakumarganesh monolithicwaferscaleintegrationofsiliconnanoribbonsensorswithcmosforlabonchipapplication
AT hellstrompererik monolithicwaferscaleintegrationofsiliconnanoribbonsensorswithcmosforlabonchipapplication
AT ostlingmikael monolithicwaferscaleintegrationofsiliconnanoribbonsensorswithcmosforlabonchipapplication