Cargando…

Determination of Biological Activity of Recombinant Reteplase Using Clot Lysis Time and Activated Partial Thromboplastin Time (APTT) Lysis Methods: A Comparative Study

Recombinant plasminogen activator (reteplase) is a third generation thrombolytic agent which has been used on coronary artery thrombosis and acute myocardial infarction. Clot lysis assay is usually considered as a unique method to evaluate biological activity of reteplase. In this study biological a...

Descripción completa

Detalles Bibliográficos
Autores principales: Babaee, Tahereh, Fazeli, Ahmad, Hashemi-Najafabadi, Sameereh, Rastegar, Hosein, Mohammadi, Ali, Khoshayand, Mohammad Reza, Alebouyeh, Mahmoud, Fazeli, Mohammad Reza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shaheed Beheshti University of Medical Sciences 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6269549/
https://www.ncbi.nlm.nih.gov/pubmed/30568707
_version_ 1783376495190736896
author Babaee, Tahereh
Fazeli, Ahmad
Hashemi-Najafabadi, Sameereh
Rastegar, Hosein
Mohammadi, Ali
Khoshayand, Mohammad Reza
Alebouyeh, Mahmoud
Fazeli, Mohammad Reza
author_facet Babaee, Tahereh
Fazeli, Ahmad
Hashemi-Najafabadi, Sameereh
Rastegar, Hosein
Mohammadi, Ali
Khoshayand, Mohammad Reza
Alebouyeh, Mahmoud
Fazeli, Mohammad Reza
author_sort Babaee, Tahereh
collection PubMed
description Recombinant plasminogen activator (reteplase) is a third generation thrombolytic agent which has been used on coronary artery thrombosis and acute myocardial infarction. Clot lysis assay is usually considered as a unique method to evaluate biological activity of reteplase. In this study biological activity of reteplase was determined by APTT (activated partial thromboplastin time) lysis method. Validity of this method was evaluated in comparison with reference method, clot lysis time assay. Results of APTT lysis test showed good reproducibility (relative standard deviation (RSD) 3-5% for within day analysis and 4-7% for between day analysis), and accuracy (101.3-102.7%). APTT lysis responses were linear in range of 0.001-0.1 mg/mL reteplase. Therefore, APTT lysis method is applicable for biological activity determination of reteplase. Although more comprehensive studies are required to approve this test as a reference method, APTT lysis method seems to be valuable to receive more attention due to advantages of technical simplicity, sensitivity, applicability, and cost efficiency.
format Online
Article
Text
id pubmed-6269549
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Shaheed Beheshti University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-62695492018-12-19 Determination of Biological Activity of Recombinant Reteplase Using Clot Lysis Time and Activated Partial Thromboplastin Time (APTT) Lysis Methods: A Comparative Study Babaee, Tahereh Fazeli, Ahmad Hashemi-Najafabadi, Sameereh Rastegar, Hosein Mohammadi, Ali Khoshayand, Mohammad Reza Alebouyeh, Mahmoud Fazeli, Mohammad Reza Iran J Pharm Res Original Article Recombinant plasminogen activator (reteplase) is a third generation thrombolytic agent which has been used on coronary artery thrombosis and acute myocardial infarction. Clot lysis assay is usually considered as a unique method to evaluate biological activity of reteplase. In this study biological activity of reteplase was determined by APTT (activated partial thromboplastin time) lysis method. Validity of this method was evaluated in comparison with reference method, clot lysis time assay. Results of APTT lysis test showed good reproducibility (relative standard deviation (RSD) 3-5% for within day analysis and 4-7% for between day analysis), and accuracy (101.3-102.7%). APTT lysis responses were linear in range of 0.001-0.1 mg/mL reteplase. Therefore, APTT lysis method is applicable for biological activity determination of reteplase. Although more comprehensive studies are required to approve this test as a reference method, APTT lysis method seems to be valuable to receive more attention due to advantages of technical simplicity, sensitivity, applicability, and cost efficiency. Shaheed Beheshti University of Medical Sciences 2018 /pmc/articles/PMC6269549/ /pubmed/30568707 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Babaee, Tahereh
Fazeli, Ahmad
Hashemi-Najafabadi, Sameereh
Rastegar, Hosein
Mohammadi, Ali
Khoshayand, Mohammad Reza
Alebouyeh, Mahmoud
Fazeli, Mohammad Reza
Determination of Biological Activity of Recombinant Reteplase Using Clot Lysis Time and Activated Partial Thromboplastin Time (APTT) Lysis Methods: A Comparative Study
title Determination of Biological Activity of Recombinant Reteplase Using Clot Lysis Time and Activated Partial Thromboplastin Time (APTT) Lysis Methods: A Comparative Study
title_full Determination of Biological Activity of Recombinant Reteplase Using Clot Lysis Time and Activated Partial Thromboplastin Time (APTT) Lysis Methods: A Comparative Study
title_fullStr Determination of Biological Activity of Recombinant Reteplase Using Clot Lysis Time and Activated Partial Thromboplastin Time (APTT) Lysis Methods: A Comparative Study
title_full_unstemmed Determination of Biological Activity of Recombinant Reteplase Using Clot Lysis Time and Activated Partial Thromboplastin Time (APTT) Lysis Methods: A Comparative Study
title_short Determination of Biological Activity of Recombinant Reteplase Using Clot Lysis Time and Activated Partial Thromboplastin Time (APTT) Lysis Methods: A Comparative Study
title_sort determination of biological activity of recombinant reteplase using clot lysis time and activated partial thromboplastin time (aptt) lysis methods: a comparative study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6269549/
https://www.ncbi.nlm.nih.gov/pubmed/30568707
work_keys_str_mv AT babaeetahereh determinationofbiologicalactivityofrecombinantreteplaseusingclotlysistimeandactivatedpartialthromboplastintimeapttlysismethodsacomparativestudy
AT fazeliahmad determinationofbiologicalactivityofrecombinantreteplaseusingclotlysistimeandactivatedpartialthromboplastintimeapttlysismethodsacomparativestudy
AT hasheminajafabadisameereh determinationofbiologicalactivityofrecombinantreteplaseusingclotlysistimeandactivatedpartialthromboplastintimeapttlysismethodsacomparativestudy
AT rastegarhosein determinationofbiologicalactivityofrecombinantreteplaseusingclotlysistimeandactivatedpartialthromboplastintimeapttlysismethodsacomparativestudy
AT mohammadiali determinationofbiologicalactivityofrecombinantreteplaseusingclotlysistimeandactivatedpartialthromboplastintimeapttlysismethodsacomparativestudy
AT khoshayandmohammadreza determinationofbiologicalactivityofrecombinantreteplaseusingclotlysistimeandactivatedpartialthromboplastintimeapttlysismethodsacomparativestudy
AT alebouyehmahmoud determinationofbiologicalactivityofrecombinantreteplaseusingclotlysistimeandactivatedpartialthromboplastintimeapttlysismethodsacomparativestudy
AT fazelimohammadreza determinationofbiologicalactivityofrecombinantreteplaseusingclotlysistimeandactivatedpartialthromboplastintimeapttlysismethodsacomparativestudy