Wear performance of retrieved metal-on-metal Pinnacle hip arthroplasties implanted before and after 2007

OBJECTIVES: Previous studies have suggested that metal-on-metal (MoM) Pinnacle (DePuy Synthes, Warsaw, Indiana) hip arthroplasties implanted after 2006 exhibit higher failure rates. This was attributed to the production of implants with reduced diametrical clearances between their bearing surfaces,...

Descripción completa

Detalles Bibliográficos
Autores principales: Bergiers, S., Hothi, H. S., Henckel, J., Eskelinen, A., Skinner, J., Hart, A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2018
Materias:
Hip
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6269595/
https://www.ncbi.nlm.nih.gov/pubmed/30581557
http://dx.doi.org/10.1302/2046-3758.711.BJR-2018-0143.R1
_version_ 1783376505768771584
author Bergiers, S.
Hothi, H. S.
Henckel, J.
Eskelinen, A.
Skinner, J.
Hart, A.
author_facet Bergiers, S.
Hothi, H. S.
Henckel, J.
Eskelinen, A.
Skinner, J.
Hart, A.
author_sort Bergiers, S.
collection PubMed
description OBJECTIVES: Previous studies have suggested that metal-on-metal (MoM) Pinnacle (DePuy Synthes, Warsaw, Indiana) hip arthroplasties implanted after 2006 exhibit higher failure rates. This was attributed to the production of implants with reduced diametrical clearances between their bearing surfaces, which, it was speculated, were outside manufacturing tolerances. This study aimed to better understand the performance of Pinnacle Systems manufactured before and after this event. METHODS: A total of 92 retrieved MoM Pinnacle hips were analyzed, of which 45 were implanted before 2007, and 47 from 2007 onwards. The ‘pre-2007’ group contained 45 implants retrieved from 21 male and 24 female patients, with a median age of 61.3 years (interquartile range (IQR) 57.1 to 65.5); the ‘2007 onwards’ group contained 47 implants retrieved from 19 male and 28 female patients, with a median age of 61.8 years (IQR 58.5 to 67.8). The volume of material lost from their bearing and taper surfaces was measured using coordinate and roundness measuring machines. These outcomes were then compared statistically using linear regression models, adjusting for potentially confounding factors. RESULTS: There was no significant difference between the taper and bearing wear rates of the ‘pre-2007’ and ‘2007 onwards’ groups (p = 0.67 and p = 0.39, respectively). Pinnacles implanted from 2007 onwards were revised after a mean time of 50 months, which was significantly earlier than the ‘pre-2007’ hips (96 months) (p < 0.001). A reduction in the time to revision was present year on year from 2003 to 2011. CONCLUSION: We found no difference in the wear rate of these implants based on the year of implantation. The ‘pre-2007’ hips had a two-fold greater time to revision than those implanted after 2007; this may be due to the increased surveillance of MoM hips following UK regulatory advice and several high-profile failures. Interestingly, we observed a decreasing trend in the mean time to revision every year from 2003 onwards. Cite this article: S. Bergiers, H. S. Hothi, J. Henckel, A. Eskelinen, J. Skinner, A. Hart. Wear performance of retrieved metal-on-metal Pinnacle hip arthroplasties implanted before and after 2007. Bone Joint Res 2018;7:595–600. DOI: 10.1302/2046-3758.711.BJR-2018-0143.R1.
format Online
Article
Text
id pubmed-6269595
institution National Center for Biotechnology Information
language English
publishDate 2018
record_format MEDLINE/PubMed
spelling pubmed-62695952018-12-21 Wear performance of retrieved metal-on-metal Pinnacle hip arthroplasties implanted before and after 2007 Bergiers, S. Hothi, H. S. Henckel, J. Eskelinen, A. Skinner, J. Hart, A. Bone Joint Res Hip OBJECTIVES: Previous studies have suggested that metal-on-metal (MoM) Pinnacle (DePuy Synthes, Warsaw, Indiana) hip arthroplasties implanted after 2006 exhibit higher failure rates. This was attributed to the production of implants with reduced diametrical clearances between their bearing surfaces, which, it was speculated, were outside manufacturing tolerances. This study aimed to better understand the performance of Pinnacle Systems manufactured before and after this event. METHODS: A total of 92 retrieved MoM Pinnacle hips were analyzed, of which 45 were implanted before 2007, and 47 from 2007 onwards. The ‘pre-2007’ group contained 45 implants retrieved from 21 male and 24 female patients, with a median age of 61.3 years (interquartile range (IQR) 57.1 to 65.5); the ‘2007 onwards’ group contained 47 implants retrieved from 19 male and 28 female patients, with a median age of 61.8 years (IQR 58.5 to 67.8). The volume of material lost from their bearing and taper surfaces was measured using coordinate and roundness measuring machines. These outcomes were then compared statistically using linear regression models, adjusting for potentially confounding factors. RESULTS: There was no significant difference between the taper and bearing wear rates of the ‘pre-2007’ and ‘2007 onwards’ groups (p = 0.67 and p = 0.39, respectively). Pinnacles implanted from 2007 onwards were revised after a mean time of 50 months, which was significantly earlier than the ‘pre-2007’ hips (96 months) (p < 0.001). A reduction in the time to revision was present year on year from 2003 to 2011. CONCLUSION: We found no difference in the wear rate of these implants based on the year of implantation. The ‘pre-2007’ hips had a two-fold greater time to revision than those implanted after 2007; this may be due to the increased surveillance of MoM hips following UK regulatory advice and several high-profile failures. Interestingly, we observed a decreasing trend in the mean time to revision every year from 2003 onwards. Cite this article: S. Bergiers, H. S. Hothi, J. Henckel, A. Eskelinen, J. Skinner, A. Hart. Wear performance of retrieved metal-on-metal Pinnacle hip arthroplasties implanted before and after 2007. Bone Joint Res 2018;7:595–600. DOI: 10.1302/2046-3758.711.BJR-2018-0143.R1. 2018-12-01 /pmc/articles/PMC6269595/ /pubmed/30581557 http://dx.doi.org/10.1302/2046-3758.711.BJR-2018-0143.R1 Text en © 2018 Author(s) et al. This is an open-access article distributed under the terms of the Creative Commons Attributions licence (CC-BY-NC), which permits unrestricted use, distribution, and reproduction in any medium, but not for commercial gain, provided the original author and source are credited.
spellingShingle Hip
Bergiers, S.
Hothi, H. S.
Henckel, J.
Eskelinen, A.
Skinner, J.
Hart, A.
Wear performance of retrieved metal-on-metal Pinnacle hip arthroplasties implanted before and after 2007
title Wear performance of retrieved metal-on-metal Pinnacle hip arthroplasties implanted before and after 2007
title_full Wear performance of retrieved metal-on-metal Pinnacle hip arthroplasties implanted before and after 2007
title_fullStr Wear performance of retrieved metal-on-metal Pinnacle hip arthroplasties implanted before and after 2007
title_full_unstemmed Wear performance of retrieved metal-on-metal Pinnacle hip arthroplasties implanted before and after 2007
title_short Wear performance of retrieved metal-on-metal Pinnacle hip arthroplasties implanted before and after 2007
title_sort wear performance of retrieved metal-on-metal pinnacle hip arthroplasties implanted before and after 2007
topic Hip
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6269595/
https://www.ncbi.nlm.nih.gov/pubmed/30581557
http://dx.doi.org/10.1302/2046-3758.711.BJR-2018-0143.R1
work_keys_str_mv AT bergierss wearperformanceofretrievedmetalonmetalpinnaclehiparthroplastiesimplantedbeforeandafter2007
AT hothihs wearperformanceofretrievedmetalonmetalpinnaclehiparthroplastiesimplantedbeforeandafter2007
AT henckelj wearperformanceofretrievedmetalonmetalpinnaclehiparthroplastiesimplantedbeforeandafter2007
AT eskelinena wearperformanceofretrievedmetalonmetalpinnaclehiparthroplastiesimplantedbeforeandafter2007
AT skinnerj wearperformanceofretrievedmetalonmetalpinnaclehiparthroplastiesimplantedbeforeandafter2007
AT harta wearperformanceofretrievedmetalonmetalpinnaclehiparthroplastiesimplantedbeforeandafter2007