Edwards Intuity Aortic Bioprosthesis in Patient with Bicuspid Aortic Valve
Bicuspid aortic valve (BAV) is generally considered to be a contraindication to sutureless aortic valve replacement (AVR). Implantation of the Edwards Intuity aortic bioprosthesis is an innovative approach associated with superior hemodynamic performance, significantly reduced myocardial ischaemia a...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medical University Publishing House Craiova
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6269610/ https://www.ncbi.nlm.nih.gov/pubmed/30581583 http://dx.doi.org/10.12865/CHSJ.42.03.09 |
_version_ | 1783376509260529664 |
---|---|
author | CORÎCI, O.M. GAȘPAR, M. LAUFER, G. IANCĂU, M. |
author_facet | CORÎCI, O.M. GAȘPAR, M. LAUFER, G. IANCĂU, M. |
author_sort | CORÎCI, O.M. |
collection | PubMed |
description | Bicuspid aortic valve (BAV) is generally considered to be a contraindication to sutureless aortic valve replacement (AVR). Implantation of the Edwards Intuity aortic bioprosthesis is an innovative approach associated with superior hemodynamic performance, significantly reduced myocardial ischaemia and cardiopulmonary bypass times and proves to be suitable for type 1 and 2 of bicuspid aortic valves replacement. We report a case of successful AVR using a fast deployment bioprosthesis,the Edwards Intuity Valve System, in a 67-year-old woman with a bicuspid aortic valve and concomitant severe aortic stenosis. |
format | Online Article Text |
id | pubmed-6269610 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Medical University Publishing House Craiova |
record_format | MEDLINE/PubMed |
spelling | pubmed-62696102018-12-21 Edwards Intuity Aortic Bioprosthesis in Patient with Bicuspid Aortic Valve CORÎCI, O.M. GAȘPAR, M. LAUFER, G. IANCĂU, M. Curr Health Sci J Case Report Bicuspid aortic valve (BAV) is generally considered to be a contraindication to sutureless aortic valve replacement (AVR). Implantation of the Edwards Intuity aortic bioprosthesis is an innovative approach associated with superior hemodynamic performance, significantly reduced myocardial ischaemia and cardiopulmonary bypass times and proves to be suitable for type 1 and 2 of bicuspid aortic valves replacement. We report a case of successful AVR using a fast deployment bioprosthesis,the Edwards Intuity Valve System, in a 67-year-old woman with a bicuspid aortic valve and concomitant severe aortic stenosis. Medical University Publishing House Craiova 2016 2016-09-29 /pmc/articles/PMC6269610/ /pubmed/30581583 http://dx.doi.org/10.12865/CHSJ.42.03.09 Text en Copyright © 2016, Medical University Publishing House Craiova http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an open-access article distributed under the terms of a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International Public License, which permits unrestricted use, adaptation, distribution and reproduction in any medium, non-commercially, provided the new creations are licensed under identical terms as the original work and the original work is properly cited. |
spellingShingle | Case Report CORÎCI, O.M. GAȘPAR, M. LAUFER, G. IANCĂU, M. Edwards Intuity Aortic Bioprosthesis in Patient with Bicuspid Aortic Valve |
title | Edwards Intuity Aortic Bioprosthesis in Patient with Bicuspid Aortic Valve |
title_full | Edwards Intuity Aortic Bioprosthesis in Patient with Bicuspid Aortic Valve |
title_fullStr | Edwards Intuity Aortic Bioprosthesis in Patient with Bicuspid Aortic Valve |
title_full_unstemmed | Edwards Intuity Aortic Bioprosthesis in Patient with Bicuspid Aortic Valve |
title_short | Edwards Intuity Aortic Bioprosthesis in Patient with Bicuspid Aortic Valve |
title_sort | edwards intuity aortic bioprosthesis in patient with bicuspid aortic valve |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6269610/ https://www.ncbi.nlm.nih.gov/pubmed/30581583 http://dx.doi.org/10.12865/CHSJ.42.03.09 |
work_keys_str_mv | AT coriciom edwardsintuityaorticbioprosthesisinpatientwithbicuspidaorticvalve AT gasparm edwardsintuityaorticbioprosthesisinpatientwithbicuspidaorticvalve AT lauferg edwardsintuityaorticbioprosthesisinpatientwithbicuspidaorticvalve AT iancaum edwardsintuityaorticbioprosthesisinpatientwithbicuspidaorticvalve |