Determination of Phenol Compounds In Surface Water Matrices by Bar Adsorptive Microextraction-High Performance Liquid Chromatography-Diode Array Detection

Bar adsorptive microextraction combined with liquid desorption followed by high performance liquid chromatography with diode array detection (BAµE-LD/HPLC-DAD) is proposed for the determination of trace levels of five phenol compounds (3-nitrophenol, 4-nitrophenol, bisphenol-A, 4-n-octylphenol and 4...

Descripción completa

Detalles Bibliográficos
Autores principales: Neng, Nuno R., Nogueira, José M. F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6271164/
https://www.ncbi.nlm.nih.gov/pubmed/24995922
http://dx.doi.org/10.3390/molecules19079369
_version_ 1783376865298219008
author Neng, Nuno R.
Nogueira, José M. F.
author_facet Neng, Nuno R.
Nogueira, José M. F.
author_sort Neng, Nuno R.
collection PubMed
description Bar adsorptive microextraction combined with liquid desorption followed by high performance liquid chromatography with diode array detection (BAµE-LD/HPLC-DAD) is proposed for the determination of trace levels of five phenol compounds (3-nitrophenol, 4-nitrophenol, bisphenol-A, 4-n-octylphenol and 4-n-nonylphenol) in surface water matrices. By using a polystyrene-divinylbenzene copolymer (PS-DVB) sorbent phase, high selectivity and efficiency is achieved even against polydimethylsiloxane through stir bar sorptive extraction. Assays performed by BAµE(PS-DVB)-LD/HPLC-DAD on 25 mL water samples spiked at the 10.0 µg/L levels yielded recoveries over 88.0% ± 5.7% for all five analytes, under optimized experimental conditions. The analytical performance showed good precision (RSD < 15%), detection limits of 0.25 µg/L and linear dynamic ranges (1.0–25.0 μg/L) with determination coefficient higher than 0.9904. By using the standard addition method, the application of the present method to surface water matrices allowed very good performances at the trace level. The proposed methodology proved to be a suitable alternative to monitor phenol compounds in surface water matrices, showing to be easy to implement, reliable, sensitive and requiring a low sample volume.
format Online
Article
Text
id pubmed-6271164
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-62711642018-12-21 Determination of Phenol Compounds In Surface Water Matrices by Bar Adsorptive Microextraction-High Performance Liquid Chromatography-Diode Array Detection Neng, Nuno R. Nogueira, José M. F. Molecules Article Bar adsorptive microextraction combined with liquid desorption followed by high performance liquid chromatography with diode array detection (BAµE-LD/HPLC-DAD) is proposed for the determination of trace levels of five phenol compounds (3-nitrophenol, 4-nitrophenol, bisphenol-A, 4-n-octylphenol and 4-n-nonylphenol) in surface water matrices. By using a polystyrene-divinylbenzene copolymer (PS-DVB) sorbent phase, high selectivity and efficiency is achieved even against polydimethylsiloxane through stir bar sorptive extraction. Assays performed by BAµE(PS-DVB)-LD/HPLC-DAD on 25 mL water samples spiked at the 10.0 µg/L levels yielded recoveries over 88.0% ± 5.7% for all five analytes, under optimized experimental conditions. The analytical performance showed good precision (RSD < 15%), detection limits of 0.25 µg/L and linear dynamic ranges (1.0–25.0 μg/L) with determination coefficient higher than 0.9904. By using the standard addition method, the application of the present method to surface water matrices allowed very good performances at the trace level. The proposed methodology proved to be a suitable alternative to monitor phenol compounds in surface water matrices, showing to be easy to implement, reliable, sensitive and requiring a low sample volume. MDPI 2014-07-03 /pmc/articles/PMC6271164/ /pubmed/24995922 http://dx.doi.org/10.3390/molecules19079369 Text en © 2014 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Neng, Nuno R.
Nogueira, José M. F.
Determination of Phenol Compounds In Surface Water Matrices by Bar Adsorptive Microextraction-High Performance Liquid Chromatography-Diode Array Detection
title Determination of Phenol Compounds In Surface Water Matrices by Bar Adsorptive Microextraction-High Performance Liquid Chromatography-Diode Array Detection
title_full Determination of Phenol Compounds In Surface Water Matrices by Bar Adsorptive Microextraction-High Performance Liquid Chromatography-Diode Array Detection
title_fullStr Determination of Phenol Compounds In Surface Water Matrices by Bar Adsorptive Microextraction-High Performance Liquid Chromatography-Diode Array Detection
title_full_unstemmed Determination of Phenol Compounds In Surface Water Matrices by Bar Adsorptive Microextraction-High Performance Liquid Chromatography-Diode Array Detection
title_short Determination of Phenol Compounds In Surface Water Matrices by Bar Adsorptive Microextraction-High Performance Liquid Chromatography-Diode Array Detection
title_sort determination of phenol compounds in surface water matrices by bar adsorptive microextraction-high performance liquid chromatography-diode array detection
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6271164/
https://www.ncbi.nlm.nih.gov/pubmed/24995922
http://dx.doi.org/10.3390/molecules19079369
work_keys_str_mv AT nengnunor determinationofphenolcompoundsinsurfacewatermatricesbybaradsorptivemicroextractionhighperformanceliquidchromatographydiodearraydetection
AT nogueirajosemf determinationofphenolcompoundsinsurfacewatermatricesbybaradsorptivemicroextractionhighperformanceliquidchromatographydiodearraydetection