Cargando…

Image Monitoring of Pharmaceutical Blending Processes and the Determination of an End Point by Using a Portable Near-Infrared Imaging Device Based on a Polychromator-Type Near-Infrared Spectrometer with a High-speed and High-Resolution Photo Diode Array Detector

In the present study we have developed a new version (ND-NIRs) of a polychromator-type near-infrared (NIR) spectrometer with a high-resolution photo diode array detector, which we built before (D-NIRs). The new version has four 5 W halogen lamps compared with the three lamps for the older version. T...

Descripción completa

Detalles Bibliográficos
Autores principales: Murayama, Kodai, Ishikawa, Daitaro, Genkawa, Takuma, Sugino, Hiroyuki, Komiyama, Makoto, Ozaki, Yukihiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6272623/
https://www.ncbi.nlm.nih.gov/pubmed/25741896
http://dx.doi.org/10.3390/molecules20034007
_version_ 1783377199745728512
author Murayama, Kodai
Ishikawa, Daitaro
Genkawa, Takuma
Sugino, Hiroyuki
Komiyama, Makoto
Ozaki, Yukihiro
author_facet Murayama, Kodai
Ishikawa, Daitaro
Genkawa, Takuma
Sugino, Hiroyuki
Komiyama, Makoto
Ozaki, Yukihiro
author_sort Murayama, Kodai
collection PubMed
description In the present study we have developed a new version (ND-NIRs) of a polychromator-type near-infrared (NIR) spectrometer with a high-resolution photo diode array detector, which we built before (D-NIRs). The new version has four 5 W halogen lamps compared with the three lamps for the older version. The new version also has a condenser lens with a shorter focal point length. The increase in the number of the lamps and the shortening of the focal point of the condenser lens realize high signal-to-noise ratio and high-speed NIR imaging measurement. By using the ND-NIRs we carried out the in-line monitoring of pharmaceutical blending and determined an end point of the blending process. Moreover, to determinate a more accurate end point, a NIR image of the blending sample was acquired by means of a portable NIR imaging device based on ND-NIRs. The imaging result has demonstrated that the mixing time of 8 min is enough for homogeneous mixing. In this way the present study has demonstrated that ND-NIRs and the imaging system based on a ND-NIRs hold considerable promise for process analysis.
format Online
Article
Text
id pubmed-6272623
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-62726232018-12-31 Image Monitoring of Pharmaceutical Blending Processes and the Determination of an End Point by Using a Portable Near-Infrared Imaging Device Based on a Polychromator-Type Near-Infrared Spectrometer with a High-speed and High-Resolution Photo Diode Array Detector Murayama, Kodai Ishikawa, Daitaro Genkawa, Takuma Sugino, Hiroyuki Komiyama, Makoto Ozaki, Yukihiro Molecules Article In the present study we have developed a new version (ND-NIRs) of a polychromator-type near-infrared (NIR) spectrometer with a high-resolution photo diode array detector, which we built before (D-NIRs). The new version has four 5 W halogen lamps compared with the three lamps for the older version. The new version also has a condenser lens with a shorter focal point length. The increase in the number of the lamps and the shortening of the focal point of the condenser lens realize high signal-to-noise ratio and high-speed NIR imaging measurement. By using the ND-NIRs we carried out the in-line monitoring of pharmaceutical blending and determined an end point of the blending process. Moreover, to determinate a more accurate end point, a NIR image of the blending sample was acquired by means of a portable NIR imaging device based on ND-NIRs. The imaging result has demonstrated that the mixing time of 8 min is enough for homogeneous mixing. In this way the present study has demonstrated that ND-NIRs and the imaging system based on a ND-NIRs hold considerable promise for process analysis. MDPI 2015-03-03 /pmc/articles/PMC6272623/ /pubmed/25741896 http://dx.doi.org/10.3390/molecules20034007 Text en © 2015 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Murayama, Kodai
Ishikawa, Daitaro
Genkawa, Takuma
Sugino, Hiroyuki
Komiyama, Makoto
Ozaki, Yukihiro
Image Monitoring of Pharmaceutical Blending Processes and the Determination of an End Point by Using a Portable Near-Infrared Imaging Device Based on a Polychromator-Type Near-Infrared Spectrometer with a High-speed and High-Resolution Photo Diode Array Detector
title Image Monitoring of Pharmaceutical Blending Processes and the Determination of an End Point by Using a Portable Near-Infrared Imaging Device Based on a Polychromator-Type Near-Infrared Spectrometer with a High-speed and High-Resolution Photo Diode Array Detector
title_full Image Monitoring of Pharmaceutical Blending Processes and the Determination of an End Point by Using a Portable Near-Infrared Imaging Device Based on a Polychromator-Type Near-Infrared Spectrometer with a High-speed and High-Resolution Photo Diode Array Detector
title_fullStr Image Monitoring of Pharmaceutical Blending Processes and the Determination of an End Point by Using a Portable Near-Infrared Imaging Device Based on a Polychromator-Type Near-Infrared Spectrometer with a High-speed and High-Resolution Photo Diode Array Detector
title_full_unstemmed Image Monitoring of Pharmaceutical Blending Processes and the Determination of an End Point by Using a Portable Near-Infrared Imaging Device Based on a Polychromator-Type Near-Infrared Spectrometer with a High-speed and High-Resolution Photo Diode Array Detector
title_short Image Monitoring of Pharmaceutical Blending Processes and the Determination of an End Point by Using a Portable Near-Infrared Imaging Device Based on a Polychromator-Type Near-Infrared Spectrometer with a High-speed and High-Resolution Photo Diode Array Detector
title_sort image monitoring of pharmaceutical blending processes and the determination of an end point by using a portable near-infrared imaging device based on a polychromator-type near-infrared spectrometer with a high-speed and high-resolution photo diode array detector
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6272623/
https://www.ncbi.nlm.nih.gov/pubmed/25741896
http://dx.doi.org/10.3390/molecules20034007
work_keys_str_mv AT murayamakodai imagemonitoringofpharmaceuticalblendingprocessesandthedeterminationofanendpointbyusingaportablenearinfraredimagingdevicebasedonapolychromatortypenearinfraredspectrometerwithahighspeedandhighresolutionphotodiodearraydetector
AT ishikawadaitaro imagemonitoringofpharmaceuticalblendingprocessesandthedeterminationofanendpointbyusingaportablenearinfraredimagingdevicebasedonapolychromatortypenearinfraredspectrometerwithahighspeedandhighresolutionphotodiodearraydetector
AT genkawatakuma imagemonitoringofpharmaceuticalblendingprocessesandthedeterminationofanendpointbyusingaportablenearinfraredimagingdevicebasedonapolychromatortypenearinfraredspectrometerwithahighspeedandhighresolutionphotodiodearraydetector
AT suginohiroyuki imagemonitoringofpharmaceuticalblendingprocessesandthedeterminationofanendpointbyusingaportablenearinfraredimagingdevicebasedonapolychromatortypenearinfraredspectrometerwithahighspeedandhighresolutionphotodiodearraydetector
AT komiyamamakoto imagemonitoringofpharmaceuticalblendingprocessesandthedeterminationofanendpointbyusingaportablenearinfraredimagingdevicebasedonapolychromatortypenearinfraredspectrometerwithahighspeedandhighresolutionphotodiodearraydetector
AT ozakiyukihiro imagemonitoringofpharmaceuticalblendingprocessesandthedeterminationofanendpointbyusingaportablenearinfraredimagingdevicebasedonapolychromatortypenearinfraredspectrometerwithahighspeedandhighresolutionphotodiodearraydetector