Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional Methods

The evaluation of weight average molecular weight (Mw) and molecular weight distribution represents one of the most controversial aspects concerning the characterization of low molecular weight heparins (LMWHs). As the most commonly used method for the measurement of such parameters is high performa...

Descripción completa

Detalles Bibliográficos
Autores principales: Bisio, Antonella, Mantegazza, Alessandra, Vecchietti, Davide, Bensi, Donata, Coppa, Alessia, Torri, Giangiacomo, Bertini, Sabrina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6272732/
https://www.ncbi.nlm.nih.gov/pubmed/25808152
http://dx.doi.org/10.3390/molecules20035085
_version_ 1783377225372925952
author Bisio, Antonella
Mantegazza, Alessandra
Vecchietti, Davide
Bensi, Donata
Coppa, Alessia
Torri, Giangiacomo
Bertini, Sabrina
author_facet Bisio, Antonella
Mantegazza, Alessandra
Vecchietti, Davide
Bensi, Donata
Coppa, Alessia
Torri, Giangiacomo
Bertini, Sabrina
author_sort Bisio, Antonella
collection PubMed
description The evaluation of weight average molecular weight (Mw) and molecular weight distribution represents one of the most controversial aspects concerning the characterization of low molecular weight heparins (LMWHs). As the most commonly used method for the measurement of such parameters is high performance size exclusion chromatography (HP-SEC), the soundness of results mainly depends on the appropriate calibration of the chromatographic columns used. With the aim of meeting the requirement of proper Mw standards for LMWHs, in the present work the determination of molecular weight parameters (Mw and Mn) by HP-SEC combined with a triple detector array (TDA) was performed. The HP-SEC/TDA technique permits the evaluation of polymeric samples by exploiting the combined and simultaneous action of three on-line detectors: light scattering detectors (LALLS/RALLS); refractometer and viscometer. Three commercial LMWH samples, enoxaparin, tinzaparin and dalteparin, a γ-ray depolymerized heparin (γ-Hep) and its chromatographic fractions, and a synthetic pentasaccharide were analysed by HP-SEC/TDA. The same samples were analysed also with a conventional HP-SEC method employing refractive index (RI) and UV detectors and two different chromatographic column set, silica gel and polymeric gel columns. In both chromatographic systems, two different calibration curves were built up by using (i) γ-Hep chromatographic fractions and the corresponding Mw parameters obtained via HP-SEC/TDA; (ii) the whole γ-Hep preparation with broad Mw dispersion and the corresponding cumulative distribution function calculated via HP-SEC/TDA. In addition, also a chromatographic column calibration according to European Pharmacopoeia indication was built up. By comparing all the obtained results, some important differences among Mw and size distribution values of the three LMWHs were found with the five different calibration methods and with HP-SEC/TDA method. In particular, the detection of the lower molecular weight components turned out to be the most critical aspect. Whereas HP-SEC/TDA may underestimate species under 2 KDa when present in low concentration, other methods appeared to emphasize their content.
format Online
Article
Text
id pubmed-6272732
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-62727322018-12-31 Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional Methods Bisio, Antonella Mantegazza, Alessandra Vecchietti, Davide Bensi, Donata Coppa, Alessia Torri, Giangiacomo Bertini, Sabrina Molecules Article The evaluation of weight average molecular weight (Mw) and molecular weight distribution represents one of the most controversial aspects concerning the characterization of low molecular weight heparins (LMWHs). As the most commonly used method for the measurement of such parameters is high performance size exclusion chromatography (HP-SEC), the soundness of results mainly depends on the appropriate calibration of the chromatographic columns used. With the aim of meeting the requirement of proper Mw standards for LMWHs, in the present work the determination of molecular weight parameters (Mw and Mn) by HP-SEC combined with a triple detector array (TDA) was performed. The HP-SEC/TDA technique permits the evaluation of polymeric samples by exploiting the combined and simultaneous action of three on-line detectors: light scattering detectors (LALLS/RALLS); refractometer and viscometer. Three commercial LMWH samples, enoxaparin, tinzaparin and dalteparin, a γ-ray depolymerized heparin (γ-Hep) and its chromatographic fractions, and a synthetic pentasaccharide were analysed by HP-SEC/TDA. The same samples were analysed also with a conventional HP-SEC method employing refractive index (RI) and UV detectors and two different chromatographic column set, silica gel and polymeric gel columns. In both chromatographic systems, two different calibration curves were built up by using (i) γ-Hep chromatographic fractions and the corresponding Mw parameters obtained via HP-SEC/TDA; (ii) the whole γ-Hep preparation with broad Mw dispersion and the corresponding cumulative distribution function calculated via HP-SEC/TDA. In addition, also a chromatographic column calibration according to European Pharmacopoeia indication was built up. By comparing all the obtained results, some important differences among Mw and size distribution values of the three LMWHs were found with the five different calibration methods and with HP-SEC/TDA method. In particular, the detection of the lower molecular weight components turned out to be the most critical aspect. Whereas HP-SEC/TDA may underestimate species under 2 KDa when present in low concentration, other methods appeared to emphasize their content. MDPI 2015-03-19 /pmc/articles/PMC6272732/ /pubmed/25808152 http://dx.doi.org/10.3390/molecules20035085 Text en © 2015 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bisio, Antonella
Mantegazza, Alessandra
Vecchietti, Davide
Bensi, Donata
Coppa, Alessia
Torri, Giangiacomo
Bertini, Sabrina
Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional Methods
title Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional Methods
title_full Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional Methods
title_fullStr Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional Methods
title_full_unstemmed Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional Methods
title_short Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional Methods
title_sort determination of the molecular weight of low-molecular-weight heparins by using high-pressure size exclusion chromatography on line with a triple detector array and conventional methods
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6272732/
https://www.ncbi.nlm.nih.gov/pubmed/25808152
http://dx.doi.org/10.3390/molecules20035085
work_keys_str_mv AT bisioantonella determinationofthemolecularweightoflowmolecularweightheparinsbyusinghighpressuresizeexclusionchromatographyonlinewithatripledetectorarrayandconventionalmethods
AT mantegazzaalessandra determinationofthemolecularweightoflowmolecularweightheparinsbyusinghighpressuresizeexclusionchromatographyonlinewithatripledetectorarrayandconventionalmethods
AT vecchiettidavide determinationofthemolecularweightoflowmolecularweightheparinsbyusinghighpressuresizeexclusionchromatographyonlinewithatripledetectorarrayandconventionalmethods
AT bensidonata determinationofthemolecularweightoflowmolecularweightheparinsbyusinghighpressuresizeexclusionchromatographyonlinewithatripledetectorarrayandconventionalmethods
AT coppaalessia determinationofthemolecularweightoflowmolecularweightheparinsbyusinghighpressuresizeexclusionchromatographyonlinewithatripledetectorarrayandconventionalmethods
AT torrigiangiacomo determinationofthemolecularweightoflowmolecularweightheparinsbyusinghighpressuresizeexclusionchromatographyonlinewithatripledetectorarrayandconventionalmethods
AT bertinisabrina determinationofthemolecularweightoflowmolecularweightheparinsbyusinghighpressuresizeexclusionchromatographyonlinewithatripledetectorarrayandconventionalmethods