Cargando…
Validation and Application of an Ultra High-Performance Liquid Chromatography Tandem Mass Spectrometry Method for Yuanhuacine Determination in Rat Plasma after Pulmonary Administration: Pharmacokinetic Evaluation of a New Drug Delivery System
Yuanhuacine was found to have significant inhibitory activity against A-549 human lung cancer cells. However, there would be serious adverse toxicity effects after systemic administration of yuanhuacine, such as by oral and intravenous ways. In order to achieve better curative effect and to alleviat...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6274523/ https://www.ncbi.nlm.nih.gov/pubmed/27999290 http://dx.doi.org/10.3390/molecules21121733 |
_version_ | 1783377638218268672 |
---|---|
author | Li, Man Liu, Xiao Cai, Hao Shen, Zhichun Xu, Liu Li, Weidong Wu, Li Duan, Jinao Chen, Zhipeng |
author_facet | Li, Man Liu, Xiao Cai, Hao Shen, Zhichun Xu, Liu Li, Weidong Wu, Li Duan, Jinao Chen, Zhipeng |
author_sort | Li, Man |
collection | PubMed |
description | Yuanhuacine was found to have significant inhibitory activity against A-549 human lung cancer cells. However, there would be serious adverse toxicity effects after systemic administration of yuanhuacine, such as by oral and intravenous ways. In order to achieve better curative effect and to alleviate the adverse toxicity effects, we tried to deliver yuanhuacine directly into the lungs. Ultra high-performance liquid chromatography tandem mass spectrometry (UHPLC–MS/MS) was used to detect the analyte and IS. After extraction (ether:dichloromethane = 8:1), the analyte and IS were separated on a Waters BEH-C(18) column (100 mm × 2.1 mm, 1.7 μm) under a 5 min gradient elution using a mixture of acetonitrile and 0.1% formic acid aqueous solution as mobile phase at a flow rate of 0.3 mL/min. ESI positive mode was chosen for detection. The method was fully validated for its selectivity, accuracy, precision, stability, matrix effect, and extraction recovery. This new method for yuanhuacine concentration determination in rat plasma was reliable and could be applied for its preclinical and clinical monitoring purpose. |
format | Online Article Text |
id | pubmed-6274523 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-62745232018-12-28 Validation and Application of an Ultra High-Performance Liquid Chromatography Tandem Mass Spectrometry Method for Yuanhuacine Determination in Rat Plasma after Pulmonary Administration: Pharmacokinetic Evaluation of a New Drug Delivery System Li, Man Liu, Xiao Cai, Hao Shen, Zhichun Xu, Liu Li, Weidong Wu, Li Duan, Jinao Chen, Zhipeng Molecules Article Yuanhuacine was found to have significant inhibitory activity against A-549 human lung cancer cells. However, there would be serious adverse toxicity effects after systemic administration of yuanhuacine, such as by oral and intravenous ways. In order to achieve better curative effect and to alleviate the adverse toxicity effects, we tried to deliver yuanhuacine directly into the lungs. Ultra high-performance liquid chromatography tandem mass spectrometry (UHPLC–MS/MS) was used to detect the analyte and IS. After extraction (ether:dichloromethane = 8:1), the analyte and IS were separated on a Waters BEH-C(18) column (100 mm × 2.1 mm, 1.7 μm) under a 5 min gradient elution using a mixture of acetonitrile and 0.1% formic acid aqueous solution as mobile phase at a flow rate of 0.3 mL/min. ESI positive mode was chosen for detection. The method was fully validated for its selectivity, accuracy, precision, stability, matrix effect, and extraction recovery. This new method for yuanhuacine concentration determination in rat plasma was reliable and could be applied for its preclinical and clinical monitoring purpose. MDPI 2016-12-16 /pmc/articles/PMC6274523/ /pubmed/27999290 http://dx.doi.org/10.3390/molecules21121733 Text en © 2016 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Li, Man Liu, Xiao Cai, Hao Shen, Zhichun Xu, Liu Li, Weidong Wu, Li Duan, Jinao Chen, Zhipeng Validation and Application of an Ultra High-Performance Liquid Chromatography Tandem Mass Spectrometry Method for Yuanhuacine Determination in Rat Plasma after Pulmonary Administration: Pharmacokinetic Evaluation of a New Drug Delivery System |
title | Validation and Application of an Ultra High-Performance Liquid Chromatography Tandem Mass Spectrometry Method for Yuanhuacine Determination in Rat Plasma after Pulmonary Administration: Pharmacokinetic Evaluation of a New Drug Delivery System |
title_full | Validation and Application of an Ultra High-Performance Liquid Chromatography Tandem Mass Spectrometry Method for Yuanhuacine Determination in Rat Plasma after Pulmonary Administration: Pharmacokinetic Evaluation of a New Drug Delivery System |
title_fullStr | Validation and Application of an Ultra High-Performance Liquid Chromatography Tandem Mass Spectrometry Method for Yuanhuacine Determination in Rat Plasma after Pulmonary Administration: Pharmacokinetic Evaluation of a New Drug Delivery System |
title_full_unstemmed | Validation and Application of an Ultra High-Performance Liquid Chromatography Tandem Mass Spectrometry Method for Yuanhuacine Determination in Rat Plasma after Pulmonary Administration: Pharmacokinetic Evaluation of a New Drug Delivery System |
title_short | Validation and Application of an Ultra High-Performance Liquid Chromatography Tandem Mass Spectrometry Method for Yuanhuacine Determination in Rat Plasma after Pulmonary Administration: Pharmacokinetic Evaluation of a New Drug Delivery System |
title_sort | validation and application of an ultra high-performance liquid chromatography tandem mass spectrometry method for yuanhuacine determination in rat plasma after pulmonary administration: pharmacokinetic evaluation of a new drug delivery system |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6274523/ https://www.ncbi.nlm.nih.gov/pubmed/27999290 http://dx.doi.org/10.3390/molecules21121733 |
work_keys_str_mv | AT liman validationandapplicationofanultrahighperformanceliquidchromatographytandemmassspectrometrymethodforyuanhuacinedeterminationinratplasmaafterpulmonaryadministrationpharmacokineticevaluationofanewdrugdeliverysystem AT liuxiao validationandapplicationofanultrahighperformanceliquidchromatographytandemmassspectrometrymethodforyuanhuacinedeterminationinratplasmaafterpulmonaryadministrationpharmacokineticevaluationofanewdrugdeliverysystem AT caihao validationandapplicationofanultrahighperformanceliquidchromatographytandemmassspectrometrymethodforyuanhuacinedeterminationinratplasmaafterpulmonaryadministrationpharmacokineticevaluationofanewdrugdeliverysystem AT shenzhichun validationandapplicationofanultrahighperformanceliquidchromatographytandemmassspectrometrymethodforyuanhuacinedeterminationinratplasmaafterpulmonaryadministrationpharmacokineticevaluationofanewdrugdeliverysystem AT xuliu validationandapplicationofanultrahighperformanceliquidchromatographytandemmassspectrometrymethodforyuanhuacinedeterminationinratplasmaafterpulmonaryadministrationpharmacokineticevaluationofanewdrugdeliverysystem AT liweidong validationandapplicationofanultrahighperformanceliquidchromatographytandemmassspectrometrymethodforyuanhuacinedeterminationinratplasmaafterpulmonaryadministrationpharmacokineticevaluationofanewdrugdeliverysystem AT wuli validationandapplicationofanultrahighperformanceliquidchromatographytandemmassspectrometrymethodforyuanhuacinedeterminationinratplasmaafterpulmonaryadministrationpharmacokineticevaluationofanewdrugdeliverysystem AT duanjinao validationandapplicationofanultrahighperformanceliquidchromatographytandemmassspectrometrymethodforyuanhuacinedeterminationinratplasmaafterpulmonaryadministrationpharmacokineticevaluationofanewdrugdeliverysystem AT chenzhipeng validationandapplicationofanultrahighperformanceliquidchromatographytandemmassspectrometrymethodforyuanhuacinedeterminationinratplasmaafterpulmonaryadministrationpharmacokineticevaluationofanewdrugdeliverysystem |