Comparison of two different measurement methods in evaluating basilar atherosclerotic plaque using high-resolution MRI at 3 tesla

BACKGROUND: To compare the Self-referenced and Referenced measurement methods in assessing basilar artery (BA) atherosclerotic plaque employing dark blood high-resolution MRI at 3 Tesla. METHODS: Forty patients with > 20% stenosis as identified by conventional MRA were recruited and evaluated on...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Luguang, Zhan, Qian, Peng, Wenjia, Song, Tao, Liu, Qi, Lu, Jianping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6276224/
https://www.ncbi.nlm.nih.gov/pubmed/30509197
http://dx.doi.org/10.1186/s12880-018-0293-1
_version_ 1783377972533657600
author Chen, Luguang
Zhan, Qian
Peng, Wenjia
Song, Tao
Liu, Qi
Lu, Jianping
author_facet Chen, Luguang
Zhan, Qian
Peng, Wenjia
Song, Tao
Liu, Qi
Lu, Jianping
author_sort Chen, Luguang
collection PubMed
description BACKGROUND: To compare the Self-referenced and Referenced measurement methods in assessing basilar artery (BA) atherosclerotic plaque employing dark blood high-resolution MRI at 3 Tesla. METHODS: Forty patients with > 20% stenosis as identified by conventional MRA were recruited and evaluated on a 3 Tesla MRI system. The outer wall, inner wall and lumen areas of maximal lumen narrowing site and the outer wall and lumen areas of sites that were proximal and distal to the maximal lumen narrowing site were manually traced. Plaque area (PA), stenosis rate (SR) and percent plaque burden (PPB) were calculated using the Self-referenced and Referenced measurement methods, respectively. To assess intra-observer reproducibility, BA plaque was measured twice with a 2-week interval in between measurements. RESULTS: Thirty-seven patients were included in the final analysis. There were no significant differences in PA, SR and PPB measurements between the two methods. The intra-class coefficients and coefficient of variations (CV) ranged from 0.976 to 0.990 and from 3.73 to 5.61% for the Self-referenced method and ranged from 0.928 to 0.971 and from 4.64 to 9.95% for the Referenced method, respectively. Both methods are effective in the evaluation of BA plaque. However, the CVs of the Self-referenced method is lower than the Referenced measurement method. Moreover, Bland-Altman plots showed that the Self-referenced method has a narrower interval than the Referenced measurement method. CONCLUSIONS: The Self-referenced method is better and more convenient for evaluating BA plaque, and it may serve as a promising method for evaluation of basilar atherosclerotic plaque.
format Online
Article
Text
id pubmed-6276224
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-62762242018-12-06 Comparison of two different measurement methods in evaluating basilar atherosclerotic plaque using high-resolution MRI at 3 tesla Chen, Luguang Zhan, Qian Peng, Wenjia Song, Tao Liu, Qi Lu, Jianping BMC Med Imaging Research Article BACKGROUND: To compare the Self-referenced and Referenced measurement methods in assessing basilar artery (BA) atherosclerotic plaque employing dark blood high-resolution MRI at 3 Tesla. METHODS: Forty patients with > 20% stenosis as identified by conventional MRA were recruited and evaluated on a 3 Tesla MRI system. The outer wall, inner wall and lumen areas of maximal lumen narrowing site and the outer wall and lumen areas of sites that were proximal and distal to the maximal lumen narrowing site were manually traced. Plaque area (PA), stenosis rate (SR) and percent plaque burden (PPB) were calculated using the Self-referenced and Referenced measurement methods, respectively. To assess intra-observer reproducibility, BA plaque was measured twice with a 2-week interval in between measurements. RESULTS: Thirty-seven patients were included in the final analysis. There were no significant differences in PA, SR and PPB measurements between the two methods. The intra-class coefficients and coefficient of variations (CV) ranged from 0.976 to 0.990 and from 3.73 to 5.61% for the Self-referenced method and ranged from 0.928 to 0.971 and from 4.64 to 9.95% for the Referenced method, respectively. Both methods are effective in the evaluation of BA plaque. However, the CVs of the Self-referenced method is lower than the Referenced measurement method. Moreover, Bland-Altman plots showed that the Self-referenced method has a narrower interval than the Referenced measurement method. CONCLUSIONS: The Self-referenced method is better and more convenient for evaluating BA plaque, and it may serve as a promising method for evaluation of basilar atherosclerotic plaque. BioMed Central 2018-12-03 /pmc/articles/PMC6276224/ /pubmed/30509197 http://dx.doi.org/10.1186/s12880-018-0293-1 Text en © The Author(s). 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Chen, Luguang
Zhan, Qian
Peng, Wenjia
Song, Tao
Liu, Qi
Lu, Jianping
Comparison of two different measurement methods in evaluating basilar atherosclerotic plaque using high-resolution MRI at 3 tesla
title Comparison of two different measurement methods in evaluating basilar atherosclerotic plaque using high-resolution MRI at 3 tesla
title_full Comparison of two different measurement methods in evaluating basilar atherosclerotic plaque using high-resolution MRI at 3 tesla
title_fullStr Comparison of two different measurement methods in evaluating basilar atherosclerotic plaque using high-resolution MRI at 3 tesla
title_full_unstemmed Comparison of two different measurement methods in evaluating basilar atherosclerotic plaque using high-resolution MRI at 3 tesla
title_short Comparison of two different measurement methods in evaluating basilar atherosclerotic plaque using high-resolution MRI at 3 tesla
title_sort comparison of two different measurement methods in evaluating basilar atherosclerotic plaque using high-resolution mri at 3 tesla
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6276224/
https://www.ncbi.nlm.nih.gov/pubmed/30509197
http://dx.doi.org/10.1186/s12880-018-0293-1
work_keys_str_mv AT chenluguang comparisonoftwodifferentmeasurementmethodsinevaluatingbasilaratheroscleroticplaqueusinghighresolutionmriat3tesla
AT zhanqian comparisonoftwodifferentmeasurementmethodsinevaluatingbasilaratheroscleroticplaqueusinghighresolutionmriat3tesla
AT pengwenjia comparisonoftwodifferentmeasurementmethodsinevaluatingbasilaratheroscleroticplaqueusinghighresolutionmriat3tesla
AT songtao comparisonoftwodifferentmeasurementmethodsinevaluatingbasilaratheroscleroticplaqueusinghighresolutionmriat3tesla
AT liuqi comparisonoftwodifferentmeasurementmethodsinevaluatingbasilaratheroscleroticplaqueusinghighresolutionmriat3tesla
AT lujianping comparisonoftwodifferentmeasurementmethodsinevaluatingbasilaratheroscleroticplaqueusinghighresolutionmriat3tesla