Cargando…

High reliability of morphokinetic annotations among embryologists

STUDY QUESTION: Are morphokinetic measurements of time lapse-videos of human embryos comparable among operators? SUMMARY ANSWER: There is little variation among morphokinetic measurements taken by different operators when analyzing the same time lapse-videos of human embryos. WHAT IS KNOWN ALREADY:...

Descripción completa

Detalles Bibliográficos
Autores principales: Martínez, M, Santaló, J, Rodríguez, A, Vassena, R
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6276644/
https://www.ncbi.nlm.nih.gov/pubmed/30895250
http://dx.doi.org/10.1093/hropen/hoy009
_version_ 1783378050092630016
author Martínez, M
Santaló, J
Rodríguez, A
Vassena, R
author_facet Martínez, M
Santaló, J
Rodríguez, A
Vassena, R
author_sort Martínez, M
collection PubMed
description STUDY QUESTION: Are morphokinetic measurements of time lapse-videos of human embryos comparable among operators? SUMMARY ANSWER: There is little variation among morphokinetic measurements taken by different operators when analyzing the same time lapse-videos of human embryos. WHAT IS KNOWN ALREADY: Morphokinetic analysis of preimplantation embryo development is a complementary method of embryo assessment increasingly used in IVF laboratories. Time-lapse videos of embryo development are normally viewed by trained embryologists and annotated with the times when specific developmental events occur. Such annotations form the basis of embryo selection algorithms, used to rank the embryos for transfer. It is unknown whether the reliability of morphokinetic annotations is related to the morphological characteristics of the analyzed embryo or to the ability of the embryologists performing the annotation. One study so far reported the reliability of morphokinetic annotations among three embryologists using the time-lapse system (TLS), but larger studies with different setups are needed to address this issue further. STUDY DESIGN, SIZE, DURATION: A prospective study was carried out between October 2015 and June 2016. Six embryologists with various degrees of experience in static, morphology-based evaluation, individually annotated the same 93 videos of preimplantation development, corresponding to 18 IVF/ICSI cycles, recorded with a TLS. PARTICIPANTS/MATERIALS, SETTING, METHODS: Times of second polar body extrusion, appearance and disappearance of pronuclei, and embryo cleavages (times from 2-cell to 5-cell stage: t2, t3, t4, t5) were annotated. Each embryologist was blinded to the annotations of the others. Intra- and inter-observer agreement was evaluated by computing intra-class correlation coefficients (ICCs). MAIN RESULTS AND THE ROLE OF CHANCE: In the inter-observer analysis, most ICCs obtained were higher than 0.80, indicating a high level of agreement: t2: 0.93; t3: 0.80; t4: 0.89; t5: 0.89; disappearance of two pronuclei: 0.98. However, the ICCs obtained for second polar body extrusion and the appearance of two pronuclei annotations was lower: 0.51 and 0.63, respectively, indicating an average level of agreement. The ICCs obtained from the intra-observer analysis were also higher than 0.80 (t2: 0.96; t3: 0.89; t4: 0.88; t5: 0.86; disappearance of two pronuclei: 0.96). The ICCs obtained from second polar body extrusion and the appearance of two pronuclei annotations were 0.77 and 0.66, respectively. These results indicate that developmental timings, annotated in time-lapse videos, are highly reliable both within and among observers. LIMITATIONS, REASONS FOR CAUTION: The events at the developmental stages from 6-cells to blastocyst were not evaluated; since some morphokinetic algorithms use times past the 6-cell stage in their calculations, further studies should be carried out to understand the variations among observers in these cases. WIDER IMPLICATIONS OF THE FINDINGS: Time-lapse measurement should be as objective as possible, especially for the first embryo cleavages, because they are often measured to define algorithms to assess the embryonic implantation potential. Our results show that measurements using this particular TLS are consistent and reliable both within and among operators. STUDY FUNDING/COMPETING INTEREST(S): None. TRIAL REGISTRATION NUMBER: Not applicable.
format Online
Article
Text
id pubmed-6276644
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-62766442019-03-20 High reliability of morphokinetic annotations among embryologists Martínez, M Santaló, J Rodríguez, A Vassena, R Hum Reprod Open Original Article STUDY QUESTION: Are morphokinetic measurements of time lapse-videos of human embryos comparable among operators? SUMMARY ANSWER: There is little variation among morphokinetic measurements taken by different operators when analyzing the same time lapse-videos of human embryos. WHAT IS KNOWN ALREADY: Morphokinetic analysis of preimplantation embryo development is a complementary method of embryo assessment increasingly used in IVF laboratories. Time-lapse videos of embryo development are normally viewed by trained embryologists and annotated with the times when specific developmental events occur. Such annotations form the basis of embryo selection algorithms, used to rank the embryos for transfer. It is unknown whether the reliability of morphokinetic annotations is related to the morphological characteristics of the analyzed embryo or to the ability of the embryologists performing the annotation. One study so far reported the reliability of morphokinetic annotations among three embryologists using the time-lapse system (TLS), but larger studies with different setups are needed to address this issue further. STUDY DESIGN, SIZE, DURATION: A prospective study was carried out between October 2015 and June 2016. Six embryologists with various degrees of experience in static, morphology-based evaluation, individually annotated the same 93 videos of preimplantation development, corresponding to 18 IVF/ICSI cycles, recorded with a TLS. PARTICIPANTS/MATERIALS, SETTING, METHODS: Times of second polar body extrusion, appearance and disappearance of pronuclei, and embryo cleavages (times from 2-cell to 5-cell stage: t2, t3, t4, t5) were annotated. Each embryologist was blinded to the annotations of the others. Intra- and inter-observer agreement was evaluated by computing intra-class correlation coefficients (ICCs). MAIN RESULTS AND THE ROLE OF CHANCE: In the inter-observer analysis, most ICCs obtained were higher than 0.80, indicating a high level of agreement: t2: 0.93; t3: 0.80; t4: 0.89; t5: 0.89; disappearance of two pronuclei: 0.98. However, the ICCs obtained for second polar body extrusion and the appearance of two pronuclei annotations was lower: 0.51 and 0.63, respectively, indicating an average level of agreement. The ICCs obtained from the intra-observer analysis were also higher than 0.80 (t2: 0.96; t3: 0.89; t4: 0.88; t5: 0.86; disappearance of two pronuclei: 0.96). The ICCs obtained from second polar body extrusion and the appearance of two pronuclei annotations were 0.77 and 0.66, respectively. These results indicate that developmental timings, annotated in time-lapse videos, are highly reliable both within and among observers. LIMITATIONS, REASONS FOR CAUTION: The events at the developmental stages from 6-cells to blastocyst were not evaluated; since some morphokinetic algorithms use times past the 6-cell stage in their calculations, further studies should be carried out to understand the variations among observers in these cases. WIDER IMPLICATIONS OF THE FINDINGS: Time-lapse measurement should be as objective as possible, especially for the first embryo cleavages, because they are often measured to define algorithms to assess the embryonic implantation potential. Our results show that measurements using this particular TLS are consistent and reliable both within and among operators. STUDY FUNDING/COMPETING INTEREST(S): None. TRIAL REGISTRATION NUMBER: Not applicable. Oxford University Press 2018-05-29 /pmc/articles/PMC6276644/ /pubmed/30895250 http://dx.doi.org/10.1093/hropen/hoy009 Text en © The Author(s) 2018. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Original Article
Martínez, M
Santaló, J
Rodríguez, A
Vassena, R
High reliability of morphokinetic annotations among embryologists
title High reliability of morphokinetic annotations among embryologists
title_full High reliability of morphokinetic annotations among embryologists
title_fullStr High reliability of morphokinetic annotations among embryologists
title_full_unstemmed High reliability of morphokinetic annotations among embryologists
title_short High reliability of morphokinetic annotations among embryologists
title_sort high reliability of morphokinetic annotations among embryologists
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6276644/
https://www.ncbi.nlm.nih.gov/pubmed/30895250
http://dx.doi.org/10.1093/hropen/hoy009
work_keys_str_mv AT martinezm highreliabilityofmorphokineticannotationsamongembryologists
AT santaloj highreliabilityofmorphokineticannotationsamongembryologists
AT rodrigueza highreliabilityofmorphokineticannotationsamongembryologists
AT vassenar highreliabilityofmorphokineticannotationsamongembryologists