Cargando…

Sleep EEG Derived From Behind-the-Ear Electrodes (cEEGrid) Compared to Standard Polysomnography: A Proof of Concept Study

Electroencephalography (EEG) recordings represent a vital component of the assessment of sleep physiology, but the methodology presently used is costly, intrusive to participants, and laborious in application. There is a recognized need to develop more easily applicable yet reliable EEG systems that...

Descripción completa

Detalles Bibliográficos
Autores principales: Sterr, Annette, Ebajemito, James K., Mikkelsen, Kaare B., Bonmati-Carrion, Maria A., Santhi, Nayantara, della Monica, Ciro, Grainger, Lucinda, Atzori, Giuseppe, Revell, Victoria, Debener, Stefan, Dijk, Derk-Jan, DeVos, Maarten
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6276915/
https://www.ncbi.nlm.nih.gov/pubmed/30534063
http://dx.doi.org/10.3389/fnhum.2018.00452
_version_ 1783378086143721472
author Sterr, Annette
Ebajemito, James K.
Mikkelsen, Kaare B.
Bonmati-Carrion, Maria A.
Santhi, Nayantara
della Monica, Ciro
Grainger, Lucinda
Atzori, Giuseppe
Revell, Victoria
Debener, Stefan
Dijk, Derk-Jan
DeVos, Maarten
author_facet Sterr, Annette
Ebajemito, James K.
Mikkelsen, Kaare B.
Bonmati-Carrion, Maria A.
Santhi, Nayantara
della Monica, Ciro
Grainger, Lucinda
Atzori, Giuseppe
Revell, Victoria
Debener, Stefan
Dijk, Derk-Jan
DeVos, Maarten
author_sort Sterr, Annette
collection PubMed
description Electroencephalography (EEG) recordings represent a vital component of the assessment of sleep physiology, but the methodology presently used is costly, intrusive to participants, and laborious in application. There is a recognized need to develop more easily applicable yet reliable EEG systems that allow unobtrusive long-term recording of sleep-wake EEG ideally away from the laboratory setting. cEEGrid is a recently developed flex-printed around-the-ear electrode array, which holds great potential for sleep-wake monitoring research. It is comfortable to wear, simple to apply, and minimally intrusive during sleep. Moreover, it can be combined with a smartphone-controlled miniaturized amplifier and is fully portable. Evaluation of cEEGrid as a motion-tolerant device is ongoing, but initial findings clearly indicate that it is very well suited for cognitive research. The present study aimed to explore the suitability of cEEGrid for sleep research, by testing whether cEEGrid data affords the signal quality and characteristics necessary for sleep stage scoring. In an accredited sleep laboratory, sleep data from cEEGrid and a standard PSG system were acquired simultaneously. Twenty participants were recorded for one extended nocturnal sleep opportunity. Fifteen data sets were scored manually. Sleep parameters relating to sleep maintenance and sleep architecture were then extracted and statistically assessed for signal quality and concordance. The findings suggest that the cEEGrid system is a viable and robust recording tool to capture sleep and wake EEG. Further research is needed to fully determine the suitability of cEEGrid for basic and applied research as well as sleep medicine.
format Online
Article
Text
id pubmed-6276915
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-62769152018-12-10 Sleep EEG Derived From Behind-the-Ear Electrodes (cEEGrid) Compared to Standard Polysomnography: A Proof of Concept Study Sterr, Annette Ebajemito, James K. Mikkelsen, Kaare B. Bonmati-Carrion, Maria A. Santhi, Nayantara della Monica, Ciro Grainger, Lucinda Atzori, Giuseppe Revell, Victoria Debener, Stefan Dijk, Derk-Jan DeVos, Maarten Front Hum Neurosci Neuroscience Electroencephalography (EEG) recordings represent a vital component of the assessment of sleep physiology, but the methodology presently used is costly, intrusive to participants, and laborious in application. There is a recognized need to develop more easily applicable yet reliable EEG systems that allow unobtrusive long-term recording of sleep-wake EEG ideally away from the laboratory setting. cEEGrid is a recently developed flex-printed around-the-ear electrode array, which holds great potential for sleep-wake monitoring research. It is comfortable to wear, simple to apply, and minimally intrusive during sleep. Moreover, it can be combined with a smartphone-controlled miniaturized amplifier and is fully portable. Evaluation of cEEGrid as a motion-tolerant device is ongoing, but initial findings clearly indicate that it is very well suited for cognitive research. The present study aimed to explore the suitability of cEEGrid for sleep research, by testing whether cEEGrid data affords the signal quality and characteristics necessary for sleep stage scoring. In an accredited sleep laboratory, sleep data from cEEGrid and a standard PSG system were acquired simultaneously. Twenty participants were recorded for one extended nocturnal sleep opportunity. Fifteen data sets were scored manually. Sleep parameters relating to sleep maintenance and sleep architecture were then extracted and statistically assessed for signal quality and concordance. The findings suggest that the cEEGrid system is a viable and robust recording tool to capture sleep and wake EEG. Further research is needed to fully determine the suitability of cEEGrid for basic and applied research as well as sleep medicine. Frontiers Media S.A. 2018-11-26 /pmc/articles/PMC6276915/ /pubmed/30534063 http://dx.doi.org/10.3389/fnhum.2018.00452 Text en Copyright © 2018 Sterr, Ebajemito, Mikkelsen, Bonmati-Carrion, Santhi, della Monica, Grainger, Atzori, Revell, Debener, Dijk and DeVos. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Sterr, Annette
Ebajemito, James K.
Mikkelsen, Kaare B.
Bonmati-Carrion, Maria A.
Santhi, Nayantara
della Monica, Ciro
Grainger, Lucinda
Atzori, Giuseppe
Revell, Victoria
Debener, Stefan
Dijk, Derk-Jan
DeVos, Maarten
Sleep EEG Derived From Behind-the-Ear Electrodes (cEEGrid) Compared to Standard Polysomnography: A Proof of Concept Study
title Sleep EEG Derived From Behind-the-Ear Electrodes (cEEGrid) Compared to Standard Polysomnography: A Proof of Concept Study
title_full Sleep EEG Derived From Behind-the-Ear Electrodes (cEEGrid) Compared to Standard Polysomnography: A Proof of Concept Study
title_fullStr Sleep EEG Derived From Behind-the-Ear Electrodes (cEEGrid) Compared to Standard Polysomnography: A Proof of Concept Study
title_full_unstemmed Sleep EEG Derived From Behind-the-Ear Electrodes (cEEGrid) Compared to Standard Polysomnography: A Proof of Concept Study
title_short Sleep EEG Derived From Behind-the-Ear Electrodes (cEEGrid) Compared to Standard Polysomnography: A Proof of Concept Study
title_sort sleep eeg derived from behind-the-ear electrodes (ceegrid) compared to standard polysomnography: a proof of concept study
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6276915/
https://www.ncbi.nlm.nih.gov/pubmed/30534063
http://dx.doi.org/10.3389/fnhum.2018.00452
work_keys_str_mv AT sterrannette sleepeegderivedfrombehindtheearelectrodesceegridcomparedtostandardpolysomnographyaproofofconceptstudy
AT ebajemitojamesk sleepeegderivedfrombehindtheearelectrodesceegridcomparedtostandardpolysomnographyaproofofconceptstudy
AT mikkelsenkaareb sleepeegderivedfrombehindtheearelectrodesceegridcomparedtostandardpolysomnographyaproofofconceptstudy
AT bonmaticarrionmariaa sleepeegderivedfrombehindtheearelectrodesceegridcomparedtostandardpolysomnographyaproofofconceptstudy
AT santhinayantara sleepeegderivedfrombehindtheearelectrodesceegridcomparedtostandardpolysomnographyaproofofconceptstudy
AT dellamonicaciro sleepeegderivedfrombehindtheearelectrodesceegridcomparedtostandardpolysomnographyaproofofconceptstudy
AT graingerlucinda sleepeegderivedfrombehindtheearelectrodesceegridcomparedtostandardpolysomnographyaproofofconceptstudy
AT atzorigiuseppe sleepeegderivedfrombehindtheearelectrodesceegridcomparedtostandardpolysomnographyaproofofconceptstudy
AT revellvictoria sleepeegderivedfrombehindtheearelectrodesceegridcomparedtostandardpolysomnographyaproofofconceptstudy
AT debenerstefan sleepeegderivedfrombehindtheearelectrodesceegridcomparedtostandardpolysomnographyaproofofconceptstudy
AT dijkderkjan sleepeegderivedfrombehindtheearelectrodesceegridcomparedtostandardpolysomnographyaproofofconceptstudy
AT devosmaarten sleepeegderivedfrombehindtheearelectrodesceegridcomparedtostandardpolysomnographyaproofofconceptstudy