An investigation of thermal environment of an existing UFAD system in a high-rise office building in the tropics

The current case study was conducted to identify the causes of environmental health issues in the office space associated with the existing Underfloor Air Distribution (UFAD) system in a high-rise office building in the tropics. The causes of the indoor environmental quality degradation are the key...

Descripción completa

Detalles Bibliográficos
Autores principales: Yau, Yat Huang, Poh, Kai Sin, Badarudin, Ahmad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6277336/
https://www.ncbi.nlm.nih.gov/pubmed/30729002
http://dx.doi.org/10.1007/s40201-018-0319-1
_version_ 1783378134030090240
author Yau, Yat Huang
Poh, Kai Sin
Badarudin, Ahmad
author_facet Yau, Yat Huang
Poh, Kai Sin
Badarudin, Ahmad
author_sort Yau, Yat Huang
collection PubMed
description The current case study was conducted to identify the causes of environmental health issues in the office space associated with the existing Underfloor Air Distribution (UFAD) system in a high-rise office building in the tropics. The causes of the indoor environmental quality degradation are the key to resolve the environmental health issues. Thus, the parameters such as the indoor air temperature, relative humidity (RH), relative air velocity, carbon monoxide (CO), carbon dioxide (CO(2)), formaldehyde, total volatile organic compound (TVOC) and particulate matter (PM(10)) were evaluated in five office spaces. The results showed that the diffusers were not effective in creating air mixing at the occupied space. The RH has exceeded the threshold limit of 70%. The CO(2) concentration has exceeded 1000 ppm, and the formaldehyde has exceeded 0.1 ppm. These indicate the poor design and maintenance of the building that lead to the degradation of indoor environmental quality. Long exposure to the poor indoor environmental quality will cause permanent health damages. The Indoor Air Quality (IAQ) management plan must be established and implemented in the ongoing basis to ensure the health of the occupants are safeguarded. As part of the plan, the practice to conduct an IAQ assessment once every 3 years is recommended to ensure the health and well-being of the occupants are safeguarded.
format Online
Article
Text
id pubmed-6277336
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-62773362019-10-26 An investigation of thermal environment of an existing UFAD system in a high-rise office building in the tropics Yau, Yat Huang Poh, Kai Sin Badarudin, Ahmad J Environ Health Sci Eng Research Article The current case study was conducted to identify the causes of environmental health issues in the office space associated with the existing Underfloor Air Distribution (UFAD) system in a high-rise office building in the tropics. The causes of the indoor environmental quality degradation are the key to resolve the environmental health issues. Thus, the parameters such as the indoor air temperature, relative humidity (RH), relative air velocity, carbon monoxide (CO), carbon dioxide (CO(2)), formaldehyde, total volatile organic compound (TVOC) and particulate matter (PM(10)) were evaluated in five office spaces. The results showed that the diffusers were not effective in creating air mixing at the occupied space. The RH has exceeded the threshold limit of 70%. The CO(2) concentration has exceeded 1000 ppm, and the formaldehyde has exceeded 0.1 ppm. These indicate the poor design and maintenance of the building that lead to the degradation of indoor environmental quality. Long exposure to the poor indoor environmental quality will cause permanent health damages. The Indoor Air Quality (IAQ) management plan must be established and implemented in the ongoing basis to ensure the health of the occupants are safeguarded. As part of the plan, the practice to conduct an IAQ assessment once every 3 years is recommended to ensure the health and well-being of the occupants are safeguarded. Springer International Publishing 2018-10-26 /pmc/articles/PMC6277336/ /pubmed/30729002 http://dx.doi.org/10.1007/s40201-018-0319-1 Text en © Springer Nature Switzerland AG 2018
spellingShingle Research Article
Yau, Yat Huang
Poh, Kai Sin
Badarudin, Ahmad
An investigation of thermal environment of an existing UFAD system in a high-rise office building in the tropics
title An investigation of thermal environment of an existing UFAD system in a high-rise office building in the tropics
title_full An investigation of thermal environment of an existing UFAD system in a high-rise office building in the tropics
title_fullStr An investigation of thermal environment of an existing UFAD system in a high-rise office building in the tropics
title_full_unstemmed An investigation of thermal environment of an existing UFAD system in a high-rise office building in the tropics
title_short An investigation of thermal environment of an existing UFAD system in a high-rise office building in the tropics
title_sort investigation of thermal environment of an existing ufad system in a high-rise office building in the tropics
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6277336/
https://www.ncbi.nlm.nih.gov/pubmed/30729002
http://dx.doi.org/10.1007/s40201-018-0319-1
work_keys_str_mv AT yauyathuang aninvestigationofthermalenvironmentofanexistingufadsysteminahighriseofficebuildinginthetropics
AT pohkaisin aninvestigationofthermalenvironmentofanexistingufadsysteminahighriseofficebuildinginthetropics
AT badarudinahmad aninvestigationofthermalenvironmentofanexistingufadsysteminahighriseofficebuildinginthetropics
AT yauyathuang investigationofthermalenvironmentofanexistingufadsysteminahighriseofficebuildinginthetropics
AT pohkaisin investigationofthermalenvironmentofanexistingufadsysteminahighriseofficebuildinginthetropics
AT badarudinahmad investigationofthermalenvironmentofanexistingufadsysteminahighriseofficebuildinginthetropics