Towards more accurate measurement of edge to os distance in low-lying placenta using three dimensional transvaginal ultrasound: an innovative technique

BACKGROUND: Measurement of edge to os distance (EOD) is essential to differentiate low-lying from normal placenta, and to plan for delivery. Till now, measurement by 2D TVS is the gold standard, however, its accuracy is questioned. In this study, we introduced an innovative technique for measurement...

Descripción completa

Detalles Bibliográficos
Autores principales: Sadek, Somayya M., Ahmad, Reda A., Atia, Hytham, Abdullah, Adel G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6278013/
https://www.ncbi.nlm.nih.gov/pubmed/30509241
http://dx.doi.org/10.1186/s12884-018-2107-4
_version_ 1783378266205192192
author Sadek, Somayya M.
Ahmad, Reda A.
Atia, Hytham
Abdullah, Adel G.
author_facet Sadek, Somayya M.
Ahmad, Reda A.
Atia, Hytham
Abdullah, Adel G.
author_sort Sadek, Somayya M.
collection PubMed
description BACKGROUND: Measurement of edge to os distance (EOD) is essential to differentiate low-lying from normal placenta, and to plan for delivery. Till now, measurement by 2D TVS is the gold standard, however, its accuracy is questioned. In this study, we introduced an innovative technique for measurement of EOD using 3D TVS. Our aim was to compare EOD measurements of the standard 2D technique, to those of our innovative 3D technique, and to correlate the difference, if any, with placental site and internal os width. METHODS: This study was conducted in the ultrasound unit of obstetrics and gynecology department, Zagazig University Hospitals, during the period from June 2014 to August 2017. Seventy six cases in whom the lower placental edge didn’t reach the internal os (IO), and the EOD was less than 35 mm, were included in the study. Placental location was identified by 2D transabdominal sonography then 2D TVS was used to measure the EOD in all cases. Our new technique was then applied to measure EOD by 3D TVS following stepwise manipulations of the orthogonal planes in multiplanar view. Width of IO was measured also in all cases. RESULTS: The mean EOD measured by 3D TVS was significantly shorter than that measured using the 2D TVS. Anterolateral/posterolateral and lateral placentas were associated with high discrepancy in measurements between both methods, being the highest with lateral group. There was significant positive correlation between the IO width and the degree of difference between the EOD measured by both methods. CONCLUSIONS: Two dimensional TVS may not be accurate in EOD measurements in many cases of low-lying placentas, and 3D TVS may increase the accuracy of measurements in these cases. This new method is simple, precise and easily applied. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12884-018-2107-4) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6278013
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-62780132018-12-06 Towards more accurate measurement of edge to os distance in low-lying placenta using three dimensional transvaginal ultrasound: an innovative technique Sadek, Somayya M. Ahmad, Reda A. Atia, Hytham Abdullah, Adel G. BMC Pregnancy Childbirth Research Article BACKGROUND: Measurement of edge to os distance (EOD) is essential to differentiate low-lying from normal placenta, and to plan for delivery. Till now, measurement by 2D TVS is the gold standard, however, its accuracy is questioned. In this study, we introduced an innovative technique for measurement of EOD using 3D TVS. Our aim was to compare EOD measurements of the standard 2D technique, to those of our innovative 3D technique, and to correlate the difference, if any, with placental site and internal os width. METHODS: This study was conducted in the ultrasound unit of obstetrics and gynecology department, Zagazig University Hospitals, during the period from June 2014 to August 2017. Seventy six cases in whom the lower placental edge didn’t reach the internal os (IO), and the EOD was less than 35 mm, were included in the study. Placental location was identified by 2D transabdominal sonography then 2D TVS was used to measure the EOD in all cases. Our new technique was then applied to measure EOD by 3D TVS following stepwise manipulations of the orthogonal planes in multiplanar view. Width of IO was measured also in all cases. RESULTS: The mean EOD measured by 3D TVS was significantly shorter than that measured using the 2D TVS. Anterolateral/posterolateral and lateral placentas were associated with high discrepancy in measurements between both methods, being the highest with lateral group. There was significant positive correlation between the IO width and the degree of difference between the EOD measured by both methods. CONCLUSIONS: Two dimensional TVS may not be accurate in EOD measurements in many cases of low-lying placentas, and 3D TVS may increase the accuracy of measurements in these cases. This new method is simple, precise and easily applied. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12884-018-2107-4) contains supplementary material, which is available to authorized users. BioMed Central 2018-12-04 /pmc/articles/PMC6278013/ /pubmed/30509241 http://dx.doi.org/10.1186/s12884-018-2107-4 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Sadek, Somayya M.
Ahmad, Reda A.
Atia, Hytham
Abdullah, Adel G.
Towards more accurate measurement of edge to os distance in low-lying placenta using three dimensional transvaginal ultrasound: an innovative technique
title Towards more accurate measurement of edge to os distance in low-lying placenta using three dimensional transvaginal ultrasound: an innovative technique
title_full Towards more accurate measurement of edge to os distance in low-lying placenta using three dimensional transvaginal ultrasound: an innovative technique
title_fullStr Towards more accurate measurement of edge to os distance in low-lying placenta using three dimensional transvaginal ultrasound: an innovative technique
title_full_unstemmed Towards more accurate measurement of edge to os distance in low-lying placenta using three dimensional transvaginal ultrasound: an innovative technique
title_short Towards more accurate measurement of edge to os distance in low-lying placenta using three dimensional transvaginal ultrasound: an innovative technique
title_sort towards more accurate measurement of edge to os distance in low-lying placenta using three dimensional transvaginal ultrasound: an innovative technique
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6278013/
https://www.ncbi.nlm.nih.gov/pubmed/30509241
http://dx.doi.org/10.1186/s12884-018-2107-4
work_keys_str_mv AT sadeksomayyam towardsmoreaccuratemeasurementofedgetoosdistanceinlowlyingplacentausingthreedimensionaltransvaginalultrasoundaninnovativetechnique
AT ahmadredaa towardsmoreaccuratemeasurementofedgetoosdistanceinlowlyingplacentausingthreedimensionaltransvaginalultrasoundaninnovativetechnique
AT atiahytham towardsmoreaccuratemeasurementofedgetoosdistanceinlowlyingplacentausingthreedimensionaltransvaginalultrasoundaninnovativetechnique
AT abdullahadelg towardsmoreaccuratemeasurementofedgetoosdistanceinlowlyingplacentausingthreedimensionaltransvaginalultrasoundaninnovativetechnique