A Novel Method for the Determination of Vancomycin in Serum by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application in Patients with Diabetic Foot Infections
A novel, precise, and accurate high-performance liquid chromatography-tandem mass spectrometry (Q-trap-MS) method was developed, optimized, and validated for determination of vancomycin in human serum using norvancomycin as an internal standard. Effect of different parameters on the analysis was eva...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6278353/ https://www.ncbi.nlm.nih.gov/pubmed/30423820 http://dx.doi.org/10.3390/molecules23112939 |
_version_ | 1783378346096197632 |
---|---|
author | Liu, Min Yang, Zhi-Hui Li, Guo-Hui |
author_facet | Liu, Min Yang, Zhi-Hui Li, Guo-Hui |
author_sort | Liu, Min |
collection | PubMed |
description | A novel, precise, and accurate high-performance liquid chromatography-tandem mass spectrometry (Q-trap-MS) method was developed, optimized, and validated for determination of vancomycin in human serum using norvancomycin as an internal standard. Effect of different parameters on the analysis was evaluated. ZORBAX SB-C(18) column (150 × 4.6 mm, 5 μm) using water (containing 0.1% formic acid, v/v)–acetonitrile (containing 0.1% formic acid, v/v) as a mobile phase was chosen. The calibration curve was linear over the concentration ranges of 1 to 2000 ng/mL for vancomycin. The limit of detection (LOD) and limit of quantification (LOQ) for vancomycin were 0.3 and 1.0 ng/mL. Recoveries were between 87.2 and 102.3%, which gave satisfactory precision. A total of 100 serum samples (from 50 patients with diabetic foot proven Gram-positive infection and 50 nondiabetic patients with pneumonia requiring hospitalization and antibiotic therapy) were analyzed by this method. The trough vancomycin concentrations of diabetic foot infection (DFI) patients and nondiabetic patients were 8.20 ± 2.83 μg/mL (range: 4.80–14.2 μg/mL) and 15.80 ± 5.43 μg/mL (range: 8.60–19.5 μg/mL), respectively. The method is sensitive, precise, and reproducible, it could be applied for routine laboratory analysis of vancomycin in serum samples. |
format | Online Article Text |
id | pubmed-6278353 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-62783532018-12-13 A Novel Method for the Determination of Vancomycin in Serum by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application in Patients with Diabetic Foot Infections Liu, Min Yang, Zhi-Hui Li, Guo-Hui Molecules Article A novel, precise, and accurate high-performance liquid chromatography-tandem mass spectrometry (Q-trap-MS) method was developed, optimized, and validated for determination of vancomycin in human serum using norvancomycin as an internal standard. Effect of different parameters on the analysis was evaluated. ZORBAX SB-C(18) column (150 × 4.6 mm, 5 μm) using water (containing 0.1% formic acid, v/v)–acetonitrile (containing 0.1% formic acid, v/v) as a mobile phase was chosen. The calibration curve was linear over the concentration ranges of 1 to 2000 ng/mL for vancomycin. The limit of detection (LOD) and limit of quantification (LOQ) for vancomycin were 0.3 and 1.0 ng/mL. Recoveries were between 87.2 and 102.3%, which gave satisfactory precision. A total of 100 serum samples (from 50 patients with diabetic foot proven Gram-positive infection and 50 nondiabetic patients with pneumonia requiring hospitalization and antibiotic therapy) were analyzed by this method. The trough vancomycin concentrations of diabetic foot infection (DFI) patients and nondiabetic patients were 8.20 ± 2.83 μg/mL (range: 4.80–14.2 μg/mL) and 15.80 ± 5.43 μg/mL (range: 8.60–19.5 μg/mL), respectively. The method is sensitive, precise, and reproducible, it could be applied for routine laboratory analysis of vancomycin in serum samples. MDPI 2018-11-10 /pmc/articles/PMC6278353/ /pubmed/30423820 http://dx.doi.org/10.3390/molecules23112939 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Liu, Min Yang, Zhi-Hui Li, Guo-Hui A Novel Method for the Determination of Vancomycin in Serum by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application in Patients with Diabetic Foot Infections |
title | A Novel Method for the Determination of Vancomycin in Serum by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application in Patients with Diabetic Foot Infections |
title_full | A Novel Method for the Determination of Vancomycin in Serum by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application in Patients with Diabetic Foot Infections |
title_fullStr | A Novel Method for the Determination of Vancomycin in Serum by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application in Patients with Diabetic Foot Infections |
title_full_unstemmed | A Novel Method for the Determination of Vancomycin in Serum by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application in Patients with Diabetic Foot Infections |
title_short | A Novel Method for the Determination of Vancomycin in Serum by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application in Patients with Diabetic Foot Infections |
title_sort | novel method for the determination of vancomycin in serum by high-performance liquid chromatography-tandem mass spectrometry and its application in patients with diabetic foot infections |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6278353/ https://www.ncbi.nlm.nih.gov/pubmed/30423820 http://dx.doi.org/10.3390/molecules23112939 |
work_keys_str_mv | AT liumin anovelmethodforthedeterminationofvancomycininserumbyhighperformanceliquidchromatographytandemmassspectrometryanditsapplicationinpatientswithdiabeticfootinfections AT yangzhihui anovelmethodforthedeterminationofvancomycininserumbyhighperformanceliquidchromatographytandemmassspectrometryanditsapplicationinpatientswithdiabeticfootinfections AT liguohui anovelmethodforthedeterminationofvancomycininserumbyhighperformanceliquidchromatographytandemmassspectrometryanditsapplicationinpatientswithdiabeticfootinfections AT liumin novelmethodforthedeterminationofvancomycininserumbyhighperformanceliquidchromatographytandemmassspectrometryanditsapplicationinpatientswithdiabeticfootinfections AT yangzhihui novelmethodforthedeterminationofvancomycininserumbyhighperformanceliquidchromatographytandemmassspectrometryanditsapplicationinpatientswithdiabeticfootinfections AT liguohui novelmethodforthedeterminationofvancomycininserumbyhighperformanceliquidchromatographytandemmassspectrometryanditsapplicationinpatientswithdiabeticfootinfections |