Cargando…

Diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed Crohn's disease (METRIC): a multicentre trial

BACKGROUND: Magnetic resonance enterography (MRE) and ultrasound are used to image Crohn's disease, but their comparative accuracy for assessing disease extent and activity is not known with certainty. Therefore, we did a multicentre trial to address this issue. METHODS: We recruited patients f...

Descripción completa

Detalles Bibliográficos
Autores principales: Taylor, Stuart A, Mallett, Susan, Bhatnagar, Gauraang, Baldwin-Cleland, Rachel, Bloom, Stuart, Gupta, Arun, Hamlin, Peter J, Hart, Ailsa L, Higginson, Antony, Jacobs, Ilan, McCartney, Sara, Miles, Anne, Murray, Charles D, Plumb, Andrew A, Pollok, Richard C, Punwani, Shonit, Quinn, Laura, Rodriguez-Justo, Manuel, Shabir, Zainib, Slater, Andrew, Tolan, Damian, Travis, Simon, Windsor, Alastair, Wylie, Peter, Zealley, Ian, Halligan, Steve
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6278907/
https://www.ncbi.nlm.nih.gov/pubmed/29914843
http://dx.doi.org/10.1016/S2468-1253(18)30161-4
_version_ 1783378451298779136
author Taylor, Stuart A
Mallett, Susan
Bhatnagar, Gauraang
Baldwin-Cleland, Rachel
Bloom, Stuart
Gupta, Arun
Hamlin, Peter J
Hart, Ailsa L
Higginson, Antony
Jacobs, Ilan
McCartney, Sara
Miles, Anne
Murray, Charles D
Plumb, Andrew A
Pollok, Richard C
Punwani, Shonit
Quinn, Laura
Rodriguez-Justo, Manuel
Shabir, Zainib
Slater, Andrew
Tolan, Damian
Travis, Simon
Windsor, Alastair
Wylie, Peter
Zealley, Ian
Halligan, Steve
author_facet Taylor, Stuart A
Mallett, Susan
Bhatnagar, Gauraang
Baldwin-Cleland, Rachel
Bloom, Stuart
Gupta, Arun
Hamlin, Peter J
Hart, Ailsa L
Higginson, Antony
Jacobs, Ilan
McCartney, Sara
Miles, Anne
Murray, Charles D
Plumb, Andrew A
Pollok, Richard C
Punwani, Shonit
Quinn, Laura
Rodriguez-Justo, Manuel
Shabir, Zainib
Slater, Andrew
Tolan, Damian
Travis, Simon
Windsor, Alastair
Wylie, Peter
Zealley, Ian
Halligan, Steve
author_sort Taylor, Stuart A
collection PubMed
description BACKGROUND: Magnetic resonance enterography (MRE) and ultrasound are used to image Crohn's disease, but their comparative accuracy for assessing disease extent and activity is not known with certainty. Therefore, we did a multicentre trial to address this issue. METHODS: We recruited patients from eight UK hospitals. Eligible patients were 16 years or older, with newly diagnosed Crohn's disease or with established disease and suspected relapse. Consecutive patients had MRE and ultrasound in addition to standard investigations. Discrepancy between MRE and ultrasound for the presence of small bowel disease triggered an additional investigation, if not already available. The primary outcome was difference in per-patient sensitivity for small bowel disease extent (correct identification and segmental localisation) against a construct reference standard (panel diagnosis). This trial is registered with the International Standard Randomised Controlled Trial, number ISRCTN03982913, and has been completed. FINDINGS: 284 patients completed the trial (133 in the newly diagnosed group, 151 in the relapse group). Based on the reference standard, 233 (82%) patients had small bowel Crohn's disease. The sensitivity of MRE for small bowel disease extent (80% [95% CI 72–86]) and presence (97% [91–99]) were significantly greater than that of ultrasound (70% [62–78] for disease extent, 92% [84–96] for disease presence); a 10% (95% CI 1–18; p=0·027) difference for extent, and 5% (1–9; p=0·025) difference for presence. The specificity of MRE for small bowel disease extent (95% [85–98]) was significantly greater than that of ultrasound (81% [64–91]); a difference of 14% (1–27; p=0·039). The specificity for small bowel disease presence was 96% (95% CI 86–99) with MRE and 84% (65–94) with ultrasound (difference 12% [0–25]; p=0·054). There were no serious adverse events. INTERPRETATION: Both MRE and ultrasound have high sensitivity for detecting small bowel disease presence and both are valid first-line investigations, and viable alternatives to ileocolonoscopy. However, in a national health service setting, MRE is generally the preferred radiological investigation when available because its sensitivity and specificity exceed ultrasound significantly. FUNDING: National Institute of Health and Research Health Technology Assessment.
format Online
Article
Text
id pubmed-6278907
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier B.V
record_format MEDLINE/PubMed
spelling pubmed-62789072018-12-13 Diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed Crohn's disease (METRIC): a multicentre trial Taylor, Stuart A Mallett, Susan Bhatnagar, Gauraang Baldwin-Cleland, Rachel Bloom, Stuart Gupta, Arun Hamlin, Peter J Hart, Ailsa L Higginson, Antony Jacobs, Ilan McCartney, Sara Miles, Anne Murray, Charles D Plumb, Andrew A Pollok, Richard C Punwani, Shonit Quinn, Laura Rodriguez-Justo, Manuel Shabir, Zainib Slater, Andrew Tolan, Damian Travis, Simon Windsor, Alastair Wylie, Peter Zealley, Ian Halligan, Steve Lancet Gastroenterol Hepatol Article BACKGROUND: Magnetic resonance enterography (MRE) and ultrasound are used to image Crohn's disease, but their comparative accuracy for assessing disease extent and activity is not known with certainty. Therefore, we did a multicentre trial to address this issue. METHODS: We recruited patients from eight UK hospitals. Eligible patients were 16 years or older, with newly diagnosed Crohn's disease or with established disease and suspected relapse. Consecutive patients had MRE and ultrasound in addition to standard investigations. Discrepancy between MRE and ultrasound for the presence of small bowel disease triggered an additional investigation, if not already available. The primary outcome was difference in per-patient sensitivity for small bowel disease extent (correct identification and segmental localisation) against a construct reference standard (panel diagnosis). This trial is registered with the International Standard Randomised Controlled Trial, number ISRCTN03982913, and has been completed. FINDINGS: 284 patients completed the trial (133 in the newly diagnosed group, 151 in the relapse group). Based on the reference standard, 233 (82%) patients had small bowel Crohn's disease. The sensitivity of MRE for small bowel disease extent (80% [95% CI 72–86]) and presence (97% [91–99]) were significantly greater than that of ultrasound (70% [62–78] for disease extent, 92% [84–96] for disease presence); a 10% (95% CI 1–18; p=0·027) difference for extent, and 5% (1–9; p=0·025) difference for presence. The specificity of MRE for small bowel disease extent (95% [85–98]) was significantly greater than that of ultrasound (81% [64–91]); a difference of 14% (1–27; p=0·039). The specificity for small bowel disease presence was 96% (95% CI 86–99) with MRE and 84% (65–94) with ultrasound (difference 12% [0–25]; p=0·054). There were no serious adverse events. INTERPRETATION: Both MRE and ultrasound have high sensitivity for detecting small bowel disease presence and both are valid first-line investigations, and viable alternatives to ileocolonoscopy. However, in a national health service setting, MRE is generally the preferred radiological investigation when available because its sensitivity and specificity exceed ultrasound significantly. FUNDING: National Institute of Health and Research Health Technology Assessment. Elsevier B.V 2018-06-18 /pmc/articles/PMC6278907/ /pubmed/29914843 http://dx.doi.org/10.1016/S2468-1253(18)30161-4 Text en © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Taylor, Stuart A
Mallett, Susan
Bhatnagar, Gauraang
Baldwin-Cleland, Rachel
Bloom, Stuart
Gupta, Arun
Hamlin, Peter J
Hart, Ailsa L
Higginson, Antony
Jacobs, Ilan
McCartney, Sara
Miles, Anne
Murray, Charles D
Plumb, Andrew A
Pollok, Richard C
Punwani, Shonit
Quinn, Laura
Rodriguez-Justo, Manuel
Shabir, Zainib
Slater, Andrew
Tolan, Damian
Travis, Simon
Windsor, Alastair
Wylie, Peter
Zealley, Ian
Halligan, Steve
Diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed Crohn's disease (METRIC): a multicentre trial
title Diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed Crohn's disease (METRIC): a multicentre trial
title_full Diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed Crohn's disease (METRIC): a multicentre trial
title_fullStr Diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed Crohn's disease (METRIC): a multicentre trial
title_full_unstemmed Diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed Crohn's disease (METRIC): a multicentre trial
title_short Diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed Crohn's disease (METRIC): a multicentre trial
title_sort diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed crohn's disease (metric): a multicentre trial
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6278907/
https://www.ncbi.nlm.nih.gov/pubmed/29914843
http://dx.doi.org/10.1016/S2468-1253(18)30161-4
work_keys_str_mv AT taylorstuarta diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT mallettsusan diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT bhatnagargauraang diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT baldwinclelandrachel diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT bloomstuart diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT guptaarun diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT hamlinpeterj diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT hartailsal diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT higginsonantony diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT jacobsilan diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT mccartneysara diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT milesanne diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT murraycharlesd diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT plumbandrewa diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT pollokrichardc diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT punwanishonit diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT quinnlaura diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT rodriguezjustomanuel diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT shabirzainib diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT slaterandrew diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT tolandamian diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT travissimon diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT windsoralastair diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT wyliepeter diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT zealleyian diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT halligansteve diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial
AT diagnosticaccuracyofmagneticresonanceenterographyandsmallbowelultrasoundfortheextentandactivityofnewlydiagnosedandrelapsedcrohnsdiseasemetricamulticentretrial