Cargando…
Heated humidification did not improve compliance of positive airway pressure and subjective daytime sleepiness in obstructive sleep apnea syndrome: A meta-analysis
INTRODUCTION: We performed a meta-analysis on whether heated humidification during positive airway pressure (PAP) could improve compliance and subjective daytime sleepiness in obstructive sleep apnea syndrome (OSAS) patients. MATERIALS AND METHODS: We searched PubMed, EMBASE, Medline, Cochrane Libra...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6281237/ https://www.ncbi.nlm.nih.gov/pubmed/30517168 http://dx.doi.org/10.1371/journal.pone.0207994 |
_version_ | 1783378804943618048 |
---|---|
author | Zhu, Ding Wu, Mindan Cao, Yuan Lin, Shihua Xuan, Nanxia Zhu, Chen Li, Wen Shen, Huahao |
author_facet | Zhu, Ding Wu, Mindan Cao, Yuan Lin, Shihua Xuan, Nanxia Zhu, Chen Li, Wen Shen, Huahao |
author_sort | Zhu, Ding |
collection | PubMed |
description | INTRODUCTION: We performed a meta-analysis on whether heated humidification during positive airway pressure (PAP) could improve compliance and subjective daytime sleepiness in obstructive sleep apnea syndrome (OSAS) patients. MATERIALS AND METHODS: We searched PubMed, EMBASE, Medline, Cochrane Library, Clinical Trials, Web of Science and Scopus from inception to Oct 29, 2017. We made meta-analysis on the all available randomized controlled trials (RCTs) which assessed effects of heated humidification intervention on PAP compliance and subjective daytime sleepiness, by subgroups of automatic adjusting positive airway pressure/ continuous positive airway pressure (APAP/CPAP) usage and patients with/without upper airway symptoms prior to PAP therapy. RESULTS: A total of nine RCTs were evaluated finally in this meta-analysis. When all the studies were pooled, heated humidification did not improve PAP usage time [weighted mean difference(WMD) = 13.28, 95% confidence interval(CI): -5.85 to 32.41, P = 0.17] or Epworth sleepiness scale (ESS) score (WMD = -0.63, 95% CI: -1.32 to 0.07, P = 0.08). In terms of PAP usage time, heated humidification failed to enhance compliance in both APAP (WMD = 22.34, 95%CI: -21.08 to 65.77, P = 0.31) or CPAP subgroup (WMD = 11.09, 95%CI: -10.21 to 32.40, P = 0.31) and it was also ineffective among patients with upper airway symptoms prior to PAP therapy (WMD = 22.74, 95% CI: -7.77 to 53.24, P = 0.14) or without (WMD = 13.22, 95%CI: -35.84 to 62.29, P = 0.60). In terms of ESS score, heated humidification did not reduce ESS scores in both APAP (WMD = -1.59, 95% CI: -3.81 to 0.64, P = 0.16) or CPAP subgroup (WMD = -0.39, 95% CI: -1.16 to 0.37, P = 0.32) and it was also helpless among patients with upper airway symptoms prior to PAP therapy (WMD = -1.17, 95% CI: -3.10 to 0.75, P = 0.23) or without (WMD = -0.30, 95%CI: -2.25 to 1.66, P = 0.76). CONCLUSION: Heated humidification during PAP therapy improves neither the compliance nor ESS scores in OSAS patients, no matter what types of PAP or whether the patients had upper airway symptoms prior to PAP therapy. But to the population with upper airway symptoms and the APAP users, the conclusions were limited because of small sample size and possible selection bias. More attentions should be paid to these potentially possible benefited subgroups. |
format | Online Article Text |
id | pubmed-6281237 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-62812372018-12-20 Heated humidification did not improve compliance of positive airway pressure and subjective daytime sleepiness in obstructive sleep apnea syndrome: A meta-analysis Zhu, Ding Wu, Mindan Cao, Yuan Lin, Shihua Xuan, Nanxia Zhu, Chen Li, Wen Shen, Huahao PLoS One Research Article INTRODUCTION: We performed a meta-analysis on whether heated humidification during positive airway pressure (PAP) could improve compliance and subjective daytime sleepiness in obstructive sleep apnea syndrome (OSAS) patients. MATERIALS AND METHODS: We searched PubMed, EMBASE, Medline, Cochrane Library, Clinical Trials, Web of Science and Scopus from inception to Oct 29, 2017. We made meta-analysis on the all available randomized controlled trials (RCTs) which assessed effects of heated humidification intervention on PAP compliance and subjective daytime sleepiness, by subgroups of automatic adjusting positive airway pressure/ continuous positive airway pressure (APAP/CPAP) usage and patients with/without upper airway symptoms prior to PAP therapy. RESULTS: A total of nine RCTs were evaluated finally in this meta-analysis. When all the studies were pooled, heated humidification did not improve PAP usage time [weighted mean difference(WMD) = 13.28, 95% confidence interval(CI): -5.85 to 32.41, P = 0.17] or Epworth sleepiness scale (ESS) score (WMD = -0.63, 95% CI: -1.32 to 0.07, P = 0.08). In terms of PAP usage time, heated humidification failed to enhance compliance in both APAP (WMD = 22.34, 95%CI: -21.08 to 65.77, P = 0.31) or CPAP subgroup (WMD = 11.09, 95%CI: -10.21 to 32.40, P = 0.31) and it was also ineffective among patients with upper airway symptoms prior to PAP therapy (WMD = 22.74, 95% CI: -7.77 to 53.24, P = 0.14) or without (WMD = 13.22, 95%CI: -35.84 to 62.29, P = 0.60). In terms of ESS score, heated humidification did not reduce ESS scores in both APAP (WMD = -1.59, 95% CI: -3.81 to 0.64, P = 0.16) or CPAP subgroup (WMD = -0.39, 95% CI: -1.16 to 0.37, P = 0.32) and it was also helpless among patients with upper airway symptoms prior to PAP therapy (WMD = -1.17, 95% CI: -3.10 to 0.75, P = 0.23) or without (WMD = -0.30, 95%CI: -2.25 to 1.66, P = 0.76). CONCLUSION: Heated humidification during PAP therapy improves neither the compliance nor ESS scores in OSAS patients, no matter what types of PAP or whether the patients had upper airway symptoms prior to PAP therapy. But to the population with upper airway symptoms and the APAP users, the conclusions were limited because of small sample size and possible selection bias. More attentions should be paid to these potentially possible benefited subgroups. Public Library of Science 2018-12-05 /pmc/articles/PMC6281237/ /pubmed/30517168 http://dx.doi.org/10.1371/journal.pone.0207994 Text en © 2018 Zhu et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Zhu, Ding Wu, Mindan Cao, Yuan Lin, Shihua Xuan, Nanxia Zhu, Chen Li, Wen Shen, Huahao Heated humidification did not improve compliance of positive airway pressure and subjective daytime sleepiness in obstructive sleep apnea syndrome: A meta-analysis |
title | Heated humidification did not improve compliance of positive airway pressure and subjective daytime sleepiness in obstructive sleep apnea syndrome: A meta-analysis |
title_full | Heated humidification did not improve compliance of positive airway pressure and subjective daytime sleepiness in obstructive sleep apnea syndrome: A meta-analysis |
title_fullStr | Heated humidification did not improve compliance of positive airway pressure and subjective daytime sleepiness in obstructive sleep apnea syndrome: A meta-analysis |
title_full_unstemmed | Heated humidification did not improve compliance of positive airway pressure and subjective daytime sleepiness in obstructive sleep apnea syndrome: A meta-analysis |
title_short | Heated humidification did not improve compliance of positive airway pressure and subjective daytime sleepiness in obstructive sleep apnea syndrome: A meta-analysis |
title_sort | heated humidification did not improve compliance of positive airway pressure and subjective daytime sleepiness in obstructive sleep apnea syndrome: a meta-analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6281237/ https://www.ncbi.nlm.nih.gov/pubmed/30517168 http://dx.doi.org/10.1371/journal.pone.0207994 |
work_keys_str_mv | AT zhuding heatedhumidificationdidnotimprovecomplianceofpositiveairwaypressureandsubjectivedaytimesleepinessinobstructivesleepapneasyndromeametaanalysis AT wumindan heatedhumidificationdidnotimprovecomplianceofpositiveairwaypressureandsubjectivedaytimesleepinessinobstructivesleepapneasyndromeametaanalysis AT caoyuan heatedhumidificationdidnotimprovecomplianceofpositiveairwaypressureandsubjectivedaytimesleepinessinobstructivesleepapneasyndromeametaanalysis AT linshihua heatedhumidificationdidnotimprovecomplianceofpositiveairwaypressureandsubjectivedaytimesleepinessinobstructivesleepapneasyndromeametaanalysis AT xuannanxia heatedhumidificationdidnotimprovecomplianceofpositiveairwaypressureandsubjectivedaytimesleepinessinobstructivesleepapneasyndromeametaanalysis AT zhuchen heatedhumidificationdidnotimprovecomplianceofpositiveairwaypressureandsubjectivedaytimesleepinessinobstructivesleepapneasyndromeametaanalysis AT liwen heatedhumidificationdidnotimprovecomplianceofpositiveairwaypressureandsubjectivedaytimesleepinessinobstructivesleepapneasyndromeametaanalysis AT shenhuahao heatedhumidificationdidnotimprovecomplianceofpositiveairwaypressureandsubjectivedaytimesleepinessinobstructivesleepapneasyndromeametaanalysis |