An electronic technetium-99m-diethylenetriaminepentaacetic acid glomerular filtration rate spreadsheet with novel embedded quality assurance features

BACKGROUND: Critical clinical decisions are made on the basis of the glomerular filtration rate (GFR) measured using technetium-99m-diethylenetriaminepentaacetic acid (DTPA) administration, followed by multiple time-point plasma sampling. As GFR studies rely on few data points and produce a single r...

Descripción completa

Detalles Bibliográficos
Autores principales: Klein, Ran, Razavi, Simin, Memon, Rayhan, Zuckier, Lionel S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6282670/
https://www.ncbi.nlm.nih.gov/pubmed/30362986
http://dx.doi.org/10.1097/MNM.0000000000000929
_version_ 1783379044266409984
author Klein, Ran
Razavi, Simin
Memon, Rayhan
Zuckier, Lionel S.
author_facet Klein, Ran
Razavi, Simin
Memon, Rayhan
Zuckier, Lionel S.
author_sort Klein, Ran
collection PubMed
description BACKGROUND: Critical clinical decisions are made on the basis of the glomerular filtration rate (GFR) measured using technetium-99m-diethylenetriaminepentaacetic acid (DTPA) administration, followed by multiple time-point plasma sampling. As GFR studies rely on few data points and produce a single result, they are prone to technical errors that may remain inconspicuous. OBJECTIVE: We describe a data analysis worksheet that provides real-time quality control (QC) indicators and evaluate our initial clinical experience. METHODS: Two hundred and forty-six consecutive GFR studies carried out at our clinics were included. Our protocol used plasma samples at 2, 3, and 4 h after injection of technetium-99m-DTPA. Duplicate plasma samples, background samples, and aliquots of an activity dilution standard were counted. Times were logged for injection and dilution standard preparation, blood sampling, and counting. Data were entered into a custom GFR analysis spreadsheet that flagged QC in real time at warning and error levels, including QC of the expected ratio between dilution standard counts–activity ratio (CARs) measurements, which was newly introduced to our clinic. The prevalence of QC events was analyzed in three phases: baseline, training, and evaluation (n=31, 69, and 146, respectively). RESULTS: From the baseline and training phases (n=100), CAR reference values were determined for each of two sites. In the absence of the CAR QC indicator, errors were present in 5/31 (16%) examinations, but with QC indication decreased to 7/146 (5%) (P<0.05), suggesting that the real-time QC information guided the technologists to ensure proper standard preparation and sample handling, as intended. Improvements in other QC measures were also noted, resulting in an overall error rate reduction from 23 to 8%. CONCLUSION: Real-time analysis of redundant information as a component of the GFR worksheet ensures quality results, but training of technologists and interpreting physicians is essential for optimal utilization of these QC indicators.
format Online
Article
Text
id pubmed-6282670
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-62826702019-01-14 An electronic technetium-99m-diethylenetriaminepentaacetic acid glomerular filtration rate spreadsheet with novel embedded quality assurance features Klein, Ran Razavi, Simin Memon, Rayhan Zuckier, Lionel S. Nucl Med Commun Original Articles BACKGROUND: Critical clinical decisions are made on the basis of the glomerular filtration rate (GFR) measured using technetium-99m-diethylenetriaminepentaacetic acid (DTPA) administration, followed by multiple time-point plasma sampling. As GFR studies rely on few data points and produce a single result, they are prone to technical errors that may remain inconspicuous. OBJECTIVE: We describe a data analysis worksheet that provides real-time quality control (QC) indicators and evaluate our initial clinical experience. METHODS: Two hundred and forty-six consecutive GFR studies carried out at our clinics were included. Our protocol used plasma samples at 2, 3, and 4 h after injection of technetium-99m-DTPA. Duplicate plasma samples, background samples, and aliquots of an activity dilution standard were counted. Times were logged for injection and dilution standard preparation, blood sampling, and counting. Data were entered into a custom GFR analysis spreadsheet that flagged QC in real time at warning and error levels, including QC of the expected ratio between dilution standard counts–activity ratio (CARs) measurements, which was newly introduced to our clinic. The prevalence of QC events was analyzed in three phases: baseline, training, and evaluation (n=31, 69, and 146, respectively). RESULTS: From the baseline and training phases (n=100), CAR reference values were determined for each of two sites. In the absence of the CAR QC indicator, errors were present in 5/31 (16%) examinations, but with QC indication decreased to 7/146 (5%) (P<0.05), suggesting that the real-time QC information guided the technologists to ensure proper standard preparation and sample handling, as intended. Improvements in other QC measures were also noted, resulting in an overall error rate reduction from 23 to 8%. CONCLUSION: Real-time analysis of redundant information as a component of the GFR worksheet ensures quality results, but training of technologists and interpreting physicians is essential for optimal utilization of these QC indicators. Lippincott Williams & Wilkins 2019-01 2018-10-26 /pmc/articles/PMC6282670/ /pubmed/30362986 http://dx.doi.org/10.1097/MNM.0000000000000929 Text en Copyright © 2018 Wolters Kluwer Health, Inc. All rights reserved.
spellingShingle Original Articles
Klein, Ran
Razavi, Simin
Memon, Rayhan
Zuckier, Lionel S.
An electronic technetium-99m-diethylenetriaminepentaacetic acid glomerular filtration rate spreadsheet with novel embedded quality assurance features
title An electronic technetium-99m-diethylenetriaminepentaacetic acid glomerular filtration rate spreadsheet with novel embedded quality assurance features
title_full An electronic technetium-99m-diethylenetriaminepentaacetic acid glomerular filtration rate spreadsheet with novel embedded quality assurance features
title_fullStr An electronic technetium-99m-diethylenetriaminepentaacetic acid glomerular filtration rate spreadsheet with novel embedded quality assurance features
title_full_unstemmed An electronic technetium-99m-diethylenetriaminepentaacetic acid glomerular filtration rate spreadsheet with novel embedded quality assurance features
title_short An electronic technetium-99m-diethylenetriaminepentaacetic acid glomerular filtration rate spreadsheet with novel embedded quality assurance features
title_sort electronic technetium-99m-diethylenetriaminepentaacetic acid glomerular filtration rate spreadsheet with novel embedded quality assurance features
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6282670/
https://www.ncbi.nlm.nih.gov/pubmed/30362986
http://dx.doi.org/10.1097/MNM.0000000000000929
work_keys_str_mv AT kleinran anelectronictechnetium99mdiethylenetriaminepentaaceticacidglomerularfiltrationratespreadsheetwithnovelembeddedqualityassurancefeatures
AT razavisimin anelectronictechnetium99mdiethylenetriaminepentaaceticacidglomerularfiltrationratespreadsheetwithnovelembeddedqualityassurancefeatures
AT memonrayhan anelectronictechnetium99mdiethylenetriaminepentaaceticacidglomerularfiltrationratespreadsheetwithnovelembeddedqualityassurancefeatures
AT zuckierlionels anelectronictechnetium99mdiethylenetriaminepentaaceticacidglomerularfiltrationratespreadsheetwithnovelembeddedqualityassurancefeatures
AT kleinran electronictechnetium99mdiethylenetriaminepentaaceticacidglomerularfiltrationratespreadsheetwithnovelembeddedqualityassurancefeatures
AT razavisimin electronictechnetium99mdiethylenetriaminepentaaceticacidglomerularfiltrationratespreadsheetwithnovelembeddedqualityassurancefeatures
AT memonrayhan electronictechnetium99mdiethylenetriaminepentaaceticacidglomerularfiltrationratespreadsheetwithnovelembeddedqualityassurancefeatures
AT zuckierlionels electronictechnetium99mdiethylenetriaminepentaaceticacidglomerularfiltrationratespreadsheetwithnovelembeddedqualityassurancefeatures