Cargando…

Mucosal Changes in the Small Intestines in Portal Hypertension: First Study Using the Pillcam SB3 Capsule Endoscopy System

BACKGROUND/AIMS: To evaluate patients with portal hypertension (PH) of varied etiologies for portal hypertensive enteropathy (PHE) using the PillCam SB3 capsule endoscopy (CE) system. METHODS: Consecutive patients with PH presenting with unexplained anemia and/or occult gastrointestinal bleeding wer...

Descripción completa

Detalles Bibliográficos
Autores principales: Goenka, Mahesh Kumar, Shah, Bhavik Bharat, Rai, Vijay Kumar, Jajodia, Surabhi, Goenka, Usha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Gastrointestinal Endoscopy 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6283757/
https://www.ncbi.nlm.nih.gov/pubmed/30300988
http://dx.doi.org/10.5946/ce.2018.041
_version_ 1783379210528620544
author Goenka, Mahesh Kumar
Shah, Bhavik Bharat
Rai, Vijay Kumar
Jajodia, Surabhi
Goenka, Usha
author_facet Goenka, Mahesh Kumar
Shah, Bhavik Bharat
Rai, Vijay Kumar
Jajodia, Surabhi
Goenka, Usha
author_sort Goenka, Mahesh Kumar
collection PubMed
description BACKGROUND/AIMS: To evaluate patients with portal hypertension (PH) of varied etiologies for portal hypertensive enteropathy (PHE) using the PillCam SB3 capsule endoscopy (CE) system. METHODS: Consecutive patients with PH presenting with unexplained anemia and/or occult gastrointestinal bleeding were evaluated using the PillCam SB3 CE system. Abnormal findings were categorized as vascular or non-vascular. The patients with ongoing bleeding caused by PHE were treated. The correlation of the CE scores of PHE with the clinical, laboratory, and endoscopic features was determined. RESULTS: Of the 43 patients included in the study, 41 (95.3%) showed PHE findings. These included varices (67.4%), red spots (60.5%), erythema (44.2%), villous edema (46.5%), telangiectasia (16.3%), and polyps (16.3%). The CE scores varied from 0 to 8 (mean±standard deviation, 4.09±1.8). Five patients (11.6%) showed evidence of ongoing or recent bleeding due to PHE. Three of these five patients underwent endotherapy, and one patient underwent radiological coil placement. CONCLUSIONS: The PillCam SB3 CE system revealed a high prevalence of PHE in the patients with PH. Using this system, evidence of bleeding due to PHE was found in a small but definite proportion of the patients.
format Online
Article
Text
id pubmed-6283757
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Korean Society of Gastrointestinal Endoscopy
record_format MEDLINE/PubMed
spelling pubmed-62837572018-12-20 Mucosal Changes in the Small Intestines in Portal Hypertension: First Study Using the Pillcam SB3 Capsule Endoscopy System Goenka, Mahesh Kumar Shah, Bhavik Bharat Rai, Vijay Kumar Jajodia, Surabhi Goenka, Usha Clin Endosc Original Article BACKGROUND/AIMS: To evaluate patients with portal hypertension (PH) of varied etiologies for portal hypertensive enteropathy (PHE) using the PillCam SB3 capsule endoscopy (CE) system. METHODS: Consecutive patients with PH presenting with unexplained anemia and/or occult gastrointestinal bleeding were evaluated using the PillCam SB3 CE system. Abnormal findings were categorized as vascular or non-vascular. The patients with ongoing bleeding caused by PHE were treated. The correlation of the CE scores of PHE with the clinical, laboratory, and endoscopic features was determined. RESULTS: Of the 43 patients included in the study, 41 (95.3%) showed PHE findings. These included varices (67.4%), red spots (60.5%), erythema (44.2%), villous edema (46.5%), telangiectasia (16.3%), and polyps (16.3%). The CE scores varied from 0 to 8 (mean±standard deviation, 4.09±1.8). Five patients (11.6%) showed evidence of ongoing or recent bleeding due to PHE. Three of these five patients underwent endotherapy, and one patient underwent radiological coil placement. CONCLUSIONS: The PillCam SB3 CE system revealed a high prevalence of PHE in the patients with PH. Using this system, evidence of bleeding due to PHE was found in a small but definite proportion of the patients. Korean Society of Gastrointestinal Endoscopy 2018-11 2018-10-05 /pmc/articles/PMC6283757/ /pubmed/30300988 http://dx.doi.org/10.5946/ce.2018.041 Text en Copyright © 2018 Korean Society of Gastrointestinal Endoscopy This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Goenka, Mahesh Kumar
Shah, Bhavik Bharat
Rai, Vijay Kumar
Jajodia, Surabhi
Goenka, Usha
Mucosal Changes in the Small Intestines in Portal Hypertension: First Study Using the Pillcam SB3 Capsule Endoscopy System
title Mucosal Changes in the Small Intestines in Portal Hypertension: First Study Using the Pillcam SB3 Capsule Endoscopy System
title_full Mucosal Changes in the Small Intestines in Portal Hypertension: First Study Using the Pillcam SB3 Capsule Endoscopy System
title_fullStr Mucosal Changes in the Small Intestines in Portal Hypertension: First Study Using the Pillcam SB3 Capsule Endoscopy System
title_full_unstemmed Mucosal Changes in the Small Intestines in Portal Hypertension: First Study Using the Pillcam SB3 Capsule Endoscopy System
title_short Mucosal Changes in the Small Intestines in Portal Hypertension: First Study Using the Pillcam SB3 Capsule Endoscopy System
title_sort mucosal changes in the small intestines in portal hypertension: first study using the pillcam sb3 capsule endoscopy system
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6283757/
https://www.ncbi.nlm.nih.gov/pubmed/30300988
http://dx.doi.org/10.5946/ce.2018.041
work_keys_str_mv AT goenkamaheshkumar mucosalchangesinthesmallintestinesinportalhypertensionfirststudyusingthepillcamsb3capsuleendoscopysystem
AT shahbhavikbharat mucosalchangesinthesmallintestinesinportalhypertensionfirststudyusingthepillcamsb3capsuleendoscopysystem
AT raivijaykumar mucosalchangesinthesmallintestinesinportalhypertensionfirststudyusingthepillcamsb3capsuleendoscopysystem
AT jajodiasurabhi mucosalchangesinthesmallintestinesinportalhypertensionfirststudyusingthepillcamsb3capsuleendoscopysystem
AT goenkausha mucosalchangesinthesmallintestinesinportalhypertensionfirststudyusingthepillcamsb3capsuleendoscopysystem