Cargando…
Biomechanical characterization of a novel ring connector for sutureless aortic anastomosis
The surgical treatment for aortic diseases remains a challenge for any cardiac surgeon. The use of sutureless ring connector in aortic anastomosis can simplify the procedure and shorten anastomosis time. Therefore, we developed a novel device for sutureless aortic anastomosis. A series of experiment...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Editorial Department of Journal of Biomedical Research
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6283826/ https://www.ncbi.nlm.nih.gov/pubmed/28963444 http://dx.doi.org/10.7555/JBR.31.20170011 |
_version_ | 1783379225899696128 |
---|---|
author | Liu, Huan Zhang, Shi-jiang Shao, Yong-feng Lu, Xiao-hu Gu, Wei-dong Ni, Buq-ing Gu, Qun Du, Jun-jie |
author_facet | Liu, Huan Zhang, Shi-jiang Shao, Yong-feng Lu, Xiao-hu Gu, Wei-dong Ni, Buq-ing Gu, Qun Du, Jun-jie |
author_sort | Liu, Huan |
collection | PubMed |
description | The surgical treatment for aortic diseases remains a challenge for any cardiac surgeon. The use of sutureless ring connector in aortic anastomosis can simplify the procedure and shorten anastomosis time. Therefore, we developed a novel device for sutureless aortic anastomosis. A series of experiments were carried out for tensile and leakproof-capacity assessments to verify the feasibility of the ring connector by using fresh swine aorta samples. In in vivo test, the ring connector was implanted in 6 swine with follow-up of 6 months. Radiographic and pathological studies of the aorta were performed. In the tensile tests, the strength was 32.7±5.9 Newton (N) in the sutureless anastomosis group, compared with 73.3±12.5 N in the control group by traditional manual suture. In the leakproof-capacity assessment, no sign of either leakage or bursting was evident at 280 mmHg of internal pressure in the aorta samples. In in vivo tests, it took 9.47±0.3 minutes for the sutureless anastomosis, compared with 15.58±1.39 minutes for hand-sewn suturing. Insertion was easy and rapid. Radiographic and pathological studies were performed at first month, third month and sixth month after surgery, each time obtained from the two swine, showed patency of the anastomosis and no signs of stenosis, blood leakage, migration or pseudoaneurysm formation, except one paralyzed swine developed of thrombo-occlusion at the site of the sutureless anastomosis. The result indicates that this novel ring connector offers considerable promise for sutureless aortic anastomosis. |
format | Online Article Text |
id | pubmed-6283826 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Editorial Department of Journal of Biomedical Research |
record_format | MEDLINE/PubMed |
spelling | pubmed-62838262018-12-24 Biomechanical characterization of a novel ring connector for sutureless aortic anastomosis Liu, Huan Zhang, Shi-jiang Shao, Yong-feng Lu, Xiao-hu Gu, Wei-dong Ni, Buq-ing Gu, Qun Du, Jun-jie J Biomed Res Original Article The surgical treatment for aortic diseases remains a challenge for any cardiac surgeon. The use of sutureless ring connector in aortic anastomosis can simplify the procedure and shorten anastomosis time. Therefore, we developed a novel device for sutureless aortic anastomosis. A series of experiments were carried out for tensile and leakproof-capacity assessments to verify the feasibility of the ring connector by using fresh swine aorta samples. In in vivo test, the ring connector was implanted in 6 swine with follow-up of 6 months. Radiographic and pathological studies of the aorta were performed. In the tensile tests, the strength was 32.7±5.9 Newton (N) in the sutureless anastomosis group, compared with 73.3±12.5 N in the control group by traditional manual suture. In the leakproof-capacity assessment, no sign of either leakage or bursting was evident at 280 mmHg of internal pressure in the aorta samples. In in vivo tests, it took 9.47±0.3 minutes for the sutureless anastomosis, compared with 15.58±1.39 minutes for hand-sewn suturing. Insertion was easy and rapid. Radiographic and pathological studies were performed at first month, third month and sixth month after surgery, each time obtained from the two swine, showed patency of the anastomosis and no signs of stenosis, blood leakage, migration or pseudoaneurysm formation, except one paralyzed swine developed of thrombo-occlusion at the site of the sutureless anastomosis. The result indicates that this novel ring connector offers considerable promise for sutureless aortic anastomosis. Editorial Department of Journal of Biomedical Research 2018-11-20 2018-05-28 /pmc/articles/PMC6283826/ /pubmed/28963444 http://dx.doi.org/10.7555/JBR.31.20170011 Text en /creativecommons.org/licenses/by/4.0/ This is an open access article under the Creative Commons Attribution (CC BY 4.0) license, which permits others to distribute, remix, adapt and build upon this work, for commercial use, provided the original work is properly cited |
spellingShingle | Original Article Liu, Huan Zhang, Shi-jiang Shao, Yong-feng Lu, Xiao-hu Gu, Wei-dong Ni, Buq-ing Gu, Qun Du, Jun-jie Biomechanical characterization of a novel ring connector for sutureless aortic anastomosis |
title | Biomechanical characterization of a novel ring connector for sutureless aortic anastomosis |
title_full | Biomechanical characterization of a novel ring connector for sutureless aortic anastomosis |
title_fullStr | Biomechanical characterization of a novel ring connector for sutureless aortic anastomosis |
title_full_unstemmed | Biomechanical characterization of a novel ring connector for sutureless aortic anastomosis |
title_short | Biomechanical characterization of a novel ring connector for sutureless aortic anastomosis |
title_sort | biomechanical characterization of a novel ring connector for sutureless aortic anastomosis |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6283826/ https://www.ncbi.nlm.nih.gov/pubmed/28963444 http://dx.doi.org/10.7555/JBR.31.20170011 |
work_keys_str_mv | AT liuhuan biomechanicalcharacterizationofanovelringconnectorforsuturelessaorticanastomosis AT zhangshijiang biomechanicalcharacterizationofanovelringconnectorforsuturelessaorticanastomosis AT shaoyongfeng biomechanicalcharacterizationofanovelringconnectorforsuturelessaorticanastomosis AT luxiaohu biomechanicalcharacterizationofanovelringconnectorforsuturelessaorticanastomosis AT guweidong biomechanicalcharacterizationofanovelringconnectorforsuturelessaorticanastomosis AT nibuqing biomechanicalcharacterizationofanovelringconnectorforsuturelessaorticanastomosis AT guqun biomechanicalcharacterizationofanovelringconnectorforsuturelessaorticanastomosis AT dujunjie biomechanicalcharacterizationofanovelringconnectorforsuturelessaorticanastomosis |