Cargando…

Noise insertion in CT for cocaine body packing: where is the limit of extensive dose reduction?

BACKGROUND: To evaluate the detection rate and image quality in CT-body-packer-screening at different radiation-dose levels and to determine a dose threshold that enables a reliable detection of incorporated body packs and incidental findings with a maximum of dose saving. MATERIALS AND METHODS: We...

Descripción completa

Detalles Bibliográficos
Autores principales: Aissa, Joel, Bölke, Edwin, Sawicki, Lino M., Appel, Elisabeth, Thomas, Christoph, Heusch, Philipp, Sedlmair, Martin, Krzymyk, Karl, Kröpil, Patric, Antoch, Gerald, Boos, Johannes
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6284291/
https://www.ncbi.nlm.nih.gov/pubmed/30526681
http://dx.doi.org/10.1186/s40001-018-0356-3
Descripción
Sumario:BACKGROUND: To evaluate the detection rate and image quality in CT-body-packer-screening at different radiation-dose levels and to determine a dose threshold that enables a reliable detection of incorporated body packs and incidental findings with a maximum of dose saving. MATERIALS AND METHODS: We retrospectively included 27 individuals who underwent an abdominal CT with automated exposure control due to suspected body packing. CT images were reconstructed at different radiation-dose levels of 50%, 10, 5% and 1% using iterative reconstructions. All 135 CT reconstructions were evaluated by three independent readers. Reviewers determined the presence of foreign bodies and evaluated the image quality using a 5-point ranking scale. In addition, visualization of incidental findings was assessed. RESULTS: A threshold of 5% (effective dose 0.11 ± 0.07 mSv) was necessary to correctly identify all 27 patients with suspected body packing. Extensive noise insertion to a dose level of 1% (0.02 ± 0.01 mSV) led to false-positive solid cocaine findings in three patients. Image quality was comparable between 100 and 50%. The threshold for correct identification of incidental findings was 10% of the initial dose (effective dose 0.21 ± 0.13 mSv). CONCLUSIONS: Our results indicate that dose of abdominal CT for the detection of intracorporeal cocaine body packets can be markedly reduced to up to 5% of the initial dose while still providing sufficient image quality to detect ingested body packets. However, a minimum effective dose of 0.21 mSv (10% of initial dose) seems to be required to properly identify incidental findings.