Cargando…
A ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series
ABSTRACT: BACKGROUND: The primary objective was to investigate the clinical and radiological outcome in patients undergoing major hip surgery using a novel antibiotic containing bone substitute for local augmentation in trochanteric fracture fixation or revision of total hip arthroplasty (THA). METH...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6284312/ https://www.ncbi.nlm.nih.gov/pubmed/30522476 http://dx.doi.org/10.1186/s12891-018-2360-8 |
_version_ | 1783379314556796928 |
---|---|
author | Stravinskas, Mindaugas Tarasevicius, Sarunas Laukaitis, Simonas Nilsson, Malin Raina, Deepak Bushan Lidgren, Lars |
author_facet | Stravinskas, Mindaugas Tarasevicius, Sarunas Laukaitis, Simonas Nilsson, Malin Raina, Deepak Bushan Lidgren, Lars |
author_sort | Stravinskas, Mindaugas |
collection | PubMed |
description | ABSTRACT: BACKGROUND: The primary objective was to investigate the clinical and radiological outcome in patients undergoing major hip surgery using a novel antibiotic containing bone substitute for local augmentation in trochanteric fracture fixation or revision of total hip arthroplasty (THA). METHODS: We implanted a novel biphasic bone substitute CERAMENT™|G consisting of hydroxyapatite, calcium sulphate and gentamicin for bone regeneration and local antibiotic delivery in 20 patients treated surgically for trochanteric femoral fracture or uncemented hip revision. Preoperative, postoperative, 3 months and 1 year clinical and radiological assessment were performed including registration of any complications. In one trochanteric fracture patient, histological analyses were performed of bone biopsies taken at removal of hardware. RESULTS: None of the trochanteric fractures or revision of THA showed any large migration. No local wound disturbances were seen and no infection was observed at one year follow-up. All trochanteric fractures healed at 3 months with a minimal sliding screw displacement on average 3 mm. Radiological analysis showed signs of bone remodeling and new bone formation in the substitute, illustrated also by histology in the biopsies taken from one trochanteric fracture at one year post-op. CONCLUSIONS: Local CERAMENT™|G was shown to be safe in a limited prospective major hip surgery study. Remodeling of the bone graft substitute was observed in all patients. TRIAL REGISTRATION: EU-CTR2018–004414-18 Retrospectively registered on November 20, 2018. |
format | Online Article Text |
id | pubmed-6284312 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-62843122018-12-14 A ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series Stravinskas, Mindaugas Tarasevicius, Sarunas Laukaitis, Simonas Nilsson, Malin Raina, Deepak Bushan Lidgren, Lars BMC Musculoskelet Disord Research Article ABSTRACT: BACKGROUND: The primary objective was to investigate the clinical and radiological outcome in patients undergoing major hip surgery using a novel antibiotic containing bone substitute for local augmentation in trochanteric fracture fixation or revision of total hip arthroplasty (THA). METHODS: We implanted a novel biphasic bone substitute CERAMENT™|G consisting of hydroxyapatite, calcium sulphate and gentamicin for bone regeneration and local antibiotic delivery in 20 patients treated surgically for trochanteric femoral fracture or uncemented hip revision. Preoperative, postoperative, 3 months and 1 year clinical and radiological assessment were performed including registration of any complications. In one trochanteric fracture patient, histological analyses were performed of bone biopsies taken at removal of hardware. RESULTS: None of the trochanteric fractures or revision of THA showed any large migration. No local wound disturbances were seen and no infection was observed at one year follow-up. All trochanteric fractures healed at 3 months with a minimal sliding screw displacement on average 3 mm. Radiological analysis showed signs of bone remodeling and new bone formation in the substitute, illustrated also by histology in the biopsies taken from one trochanteric fracture at one year post-op. CONCLUSIONS: Local CERAMENT™|G was shown to be safe in a limited prospective major hip surgery study. Remodeling of the bone graft substitute was observed in all patients. TRIAL REGISTRATION: EU-CTR2018–004414-18 Retrospectively registered on November 20, 2018. BioMed Central 2018-12-06 /pmc/articles/PMC6284312/ /pubmed/30522476 http://dx.doi.org/10.1186/s12891-018-2360-8 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Stravinskas, Mindaugas Tarasevicius, Sarunas Laukaitis, Simonas Nilsson, Malin Raina, Deepak Bushan Lidgren, Lars A ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series |
title | A ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series |
title_full | A ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series |
title_fullStr | A ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series |
title_full_unstemmed | A ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series |
title_short | A ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series |
title_sort | ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6284312/ https://www.ncbi.nlm.nih.gov/pubmed/30522476 http://dx.doi.org/10.1186/s12891-018-2360-8 |
work_keys_str_mv | AT stravinskasmindaugas aceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries AT taraseviciussarunas aceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries AT laukaitissimonas aceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries AT nilssonmalin aceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries AT rainadeepakbushan aceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries AT lidgrenlars aceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries AT stravinskasmindaugas ceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries AT taraseviciussarunas ceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries AT laukaitissimonas ceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries AT nilssonmalin ceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries AT rainadeepakbushan ceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries AT lidgrenlars ceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries |