Cargando…

A ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series

ABSTRACT: BACKGROUND: The primary objective was to investigate the clinical and radiological outcome in patients undergoing major hip surgery using a novel antibiotic containing bone substitute for local augmentation in trochanteric fracture fixation or revision of total hip arthroplasty (THA). METH...

Descripción completa

Detalles Bibliográficos
Autores principales: Stravinskas, Mindaugas, Tarasevicius, Sarunas, Laukaitis, Simonas, Nilsson, Malin, Raina, Deepak Bushan, Lidgren, Lars
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6284312/
https://www.ncbi.nlm.nih.gov/pubmed/30522476
http://dx.doi.org/10.1186/s12891-018-2360-8
_version_ 1783379314556796928
author Stravinskas, Mindaugas
Tarasevicius, Sarunas
Laukaitis, Simonas
Nilsson, Malin
Raina, Deepak Bushan
Lidgren, Lars
author_facet Stravinskas, Mindaugas
Tarasevicius, Sarunas
Laukaitis, Simonas
Nilsson, Malin
Raina, Deepak Bushan
Lidgren, Lars
author_sort Stravinskas, Mindaugas
collection PubMed
description ABSTRACT: BACKGROUND: The primary objective was to investigate the clinical and radiological outcome in patients undergoing major hip surgery using a novel antibiotic containing bone substitute for local augmentation in trochanteric fracture fixation or revision of total hip arthroplasty (THA). METHODS: We implanted a novel biphasic bone substitute CERAMENT™|G consisting of hydroxyapatite, calcium sulphate and gentamicin for bone regeneration and local antibiotic delivery in 20 patients treated surgically for trochanteric femoral fracture or uncemented hip revision. Preoperative, postoperative, 3 months and 1 year clinical and radiological assessment were performed including registration of any complications. In one trochanteric fracture patient, histological analyses were performed of bone biopsies taken at removal of hardware. RESULTS: None of the trochanteric fractures or revision of THA showed any large migration. No local wound disturbances were seen and no infection was observed at one year follow-up. All trochanteric fractures healed at 3 months with a minimal sliding screw displacement on average 3 mm. Radiological analysis showed signs of bone remodeling and new bone formation in the substitute, illustrated also by histology in the biopsies taken from one trochanteric fracture at one year post-op. CONCLUSIONS: Local CERAMENT™|G was shown to be safe in a limited prospective major hip surgery study. Remodeling of the bone graft substitute was observed in all patients. TRIAL REGISTRATION: EU-CTR2018–004414-18 Retrospectively registered on November 20, 2018.
format Online
Article
Text
id pubmed-6284312
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-62843122018-12-14 A ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series Stravinskas, Mindaugas Tarasevicius, Sarunas Laukaitis, Simonas Nilsson, Malin Raina, Deepak Bushan Lidgren, Lars BMC Musculoskelet Disord Research Article ABSTRACT: BACKGROUND: The primary objective was to investigate the clinical and radiological outcome in patients undergoing major hip surgery using a novel antibiotic containing bone substitute for local augmentation in trochanteric fracture fixation or revision of total hip arthroplasty (THA). METHODS: We implanted a novel biphasic bone substitute CERAMENT™|G consisting of hydroxyapatite, calcium sulphate and gentamicin for bone regeneration and local antibiotic delivery in 20 patients treated surgically for trochanteric femoral fracture or uncemented hip revision. Preoperative, postoperative, 3 months and 1 year clinical and radiological assessment were performed including registration of any complications. In one trochanteric fracture patient, histological analyses were performed of bone biopsies taken at removal of hardware. RESULTS: None of the trochanteric fractures or revision of THA showed any large migration. No local wound disturbances were seen and no infection was observed at one year follow-up. All trochanteric fractures healed at 3 months with a minimal sliding screw displacement on average 3 mm. Radiological analysis showed signs of bone remodeling and new bone formation in the substitute, illustrated also by histology in the biopsies taken from one trochanteric fracture at one year post-op. CONCLUSIONS: Local CERAMENT™|G was shown to be safe in a limited prospective major hip surgery study. Remodeling of the bone graft substitute was observed in all patients. TRIAL REGISTRATION: EU-CTR2018–004414-18 Retrospectively registered on November 20, 2018. BioMed Central 2018-12-06 /pmc/articles/PMC6284312/ /pubmed/30522476 http://dx.doi.org/10.1186/s12891-018-2360-8 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Stravinskas, Mindaugas
Tarasevicius, Sarunas
Laukaitis, Simonas
Nilsson, Malin
Raina, Deepak Bushan
Lidgren, Lars
A ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series
title A ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series
title_full A ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series
title_fullStr A ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series
title_full_unstemmed A ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series
title_short A ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series
title_sort ceramic bone substitute containing gentamicin gives good outcome in trochanteric hip fractures treated with dynamic hip screw and in revision of total hip arthroplasty: a case series
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6284312/
https://www.ncbi.nlm.nih.gov/pubmed/30522476
http://dx.doi.org/10.1186/s12891-018-2360-8
work_keys_str_mv AT stravinskasmindaugas aceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries
AT taraseviciussarunas aceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries
AT laukaitissimonas aceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries
AT nilssonmalin aceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries
AT rainadeepakbushan aceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries
AT lidgrenlars aceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries
AT stravinskasmindaugas ceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries
AT taraseviciussarunas ceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries
AT laukaitissimonas ceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries
AT nilssonmalin ceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries
AT rainadeepakbushan ceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries
AT lidgrenlars ceramicbonesubstitutecontaininggentamicingivesgoodoutcomeintrochanterichipfracturestreatedwithdynamichipscrewandinrevisionoftotalhiparthroplastyacaseseries