Cargando…

Enhanced Quantification of Retinal Perfusion by Improved Discrimination of Blood Flow From Bulk Motion Signal in OCTA

PURPOSE: Quantification of optical coherence tomography angiography (OCTA) is confounded by the prevalence of bulk motion. We have previously developed a regression-based bulk motion subtraction (rb-BMS) algorithm that estimates bulk motion velocity and corrects for its effect on flow signal. Here,...

Descripción completa

Detalles Bibliográficos
Autores principales: Camino, Acner, Zhang, Miao, Liu, Liang, Wang, Jie, Jia, Yali, Huang, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6284469/
https://www.ncbi.nlm.nih.gov/pubmed/30564509
http://dx.doi.org/10.1167/tvst.7.6.20
_version_ 1783379340741836800
author Camino, Acner
Zhang, Miao
Liu, Liang
Wang, Jie
Jia, Yali
Huang, David
author_facet Camino, Acner
Zhang, Miao
Liu, Liang
Wang, Jie
Jia, Yali
Huang, David
author_sort Camino, Acner
collection PubMed
description PURPOSE: Quantification of optical coherence tomography angiography (OCTA) is confounded by the prevalence of bulk motion. We have previously developed a regression-based bulk motion subtraction (rb-BMS) algorithm that estimates bulk motion velocity and corrects for its effect on flow signal. Here, we aim to investigate its ability to improve the reliability of capillary density (CD) quantification. METHODS: Two spectral-domain systems (70-kHz Avanti/AngioVue and 68-kHz Cirrus/AngioPlex) acquired 6 × 6-mm OCTA scans. The rb-BMS algorithm was applied on each OCTA volume. Regression analysis of angiographic versus reflectance signal of avascular A-lines in B-frames was used to set an optimized reflectance-adjusted threshold for discriminating vascular versus nonvascular voxels. The CD was calculated from en face maximum projections of the superficial vascular complex in macular scans and the nerve fiber layer plexus in disc scans, excluding large vessels. The retinal signal strength (RSS) was calculated by averaging the logarithmic-scale OCT reflectance signal, and its correlation with CD was investigated. RESULTS: Eight healthy eyes were scanned with each instrument on 2 separate days. The rb-BMS algorithm improved within-visit repeatability and between-visit reproducibility of CD compared with a global-threshold measurement algorithm. Using the rb-BMS algorithm, the CD results were less affected by RSS and the population variation was reduced. Motion-induced line artifacts were also reduced. CONCLUSIONS: The rb-BMS algorithm improved the reliability of perfusion quantification in OCTA on both Food and Drug Administration–cleared spectral-domain OCTA systems. TRANSLATIONAL RELEVANCE: The rb-BMS method helped reduce the inter-scan variability by generating accurate vessel maps, improving the reliability of retinal perfusion quantification.
format Online
Article
Text
id pubmed-6284469
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-62844692018-12-18 Enhanced Quantification of Retinal Perfusion by Improved Discrimination of Blood Flow From Bulk Motion Signal in OCTA Camino, Acner Zhang, Miao Liu, Liang Wang, Jie Jia, Yali Huang, David Transl Vis Sci Technol Articles PURPOSE: Quantification of optical coherence tomography angiography (OCTA) is confounded by the prevalence of bulk motion. We have previously developed a regression-based bulk motion subtraction (rb-BMS) algorithm that estimates bulk motion velocity and corrects for its effect on flow signal. Here, we aim to investigate its ability to improve the reliability of capillary density (CD) quantification. METHODS: Two spectral-domain systems (70-kHz Avanti/AngioVue and 68-kHz Cirrus/AngioPlex) acquired 6 × 6-mm OCTA scans. The rb-BMS algorithm was applied on each OCTA volume. Regression analysis of angiographic versus reflectance signal of avascular A-lines in B-frames was used to set an optimized reflectance-adjusted threshold for discriminating vascular versus nonvascular voxels. The CD was calculated from en face maximum projections of the superficial vascular complex in macular scans and the nerve fiber layer plexus in disc scans, excluding large vessels. The retinal signal strength (RSS) was calculated by averaging the logarithmic-scale OCT reflectance signal, and its correlation with CD was investigated. RESULTS: Eight healthy eyes were scanned with each instrument on 2 separate days. The rb-BMS algorithm improved within-visit repeatability and between-visit reproducibility of CD compared with a global-threshold measurement algorithm. Using the rb-BMS algorithm, the CD results were less affected by RSS and the population variation was reduced. Motion-induced line artifacts were also reduced. CONCLUSIONS: The rb-BMS algorithm improved the reliability of perfusion quantification in OCTA on both Food and Drug Administration–cleared spectral-domain OCTA systems. TRANSLATIONAL RELEVANCE: The rb-BMS method helped reduce the inter-scan variability by generating accurate vessel maps, improving the reliability of retinal perfusion quantification. The Association for Research in Vision and Ophthalmology 2018-12-06 /pmc/articles/PMC6284469/ /pubmed/30564509 http://dx.doi.org/10.1167/tvst.7.6.20 Text en Copyright 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Articles
Camino, Acner
Zhang, Miao
Liu, Liang
Wang, Jie
Jia, Yali
Huang, David
Enhanced Quantification of Retinal Perfusion by Improved Discrimination of Blood Flow From Bulk Motion Signal in OCTA
title Enhanced Quantification of Retinal Perfusion by Improved Discrimination of Blood Flow From Bulk Motion Signal in OCTA
title_full Enhanced Quantification of Retinal Perfusion by Improved Discrimination of Blood Flow From Bulk Motion Signal in OCTA
title_fullStr Enhanced Quantification of Retinal Perfusion by Improved Discrimination of Blood Flow From Bulk Motion Signal in OCTA
title_full_unstemmed Enhanced Quantification of Retinal Perfusion by Improved Discrimination of Blood Flow From Bulk Motion Signal in OCTA
title_short Enhanced Quantification of Retinal Perfusion by Improved Discrimination of Blood Flow From Bulk Motion Signal in OCTA
title_sort enhanced quantification of retinal perfusion by improved discrimination of blood flow from bulk motion signal in octa
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6284469/
https://www.ncbi.nlm.nih.gov/pubmed/30564509
http://dx.doi.org/10.1167/tvst.7.6.20
work_keys_str_mv AT caminoacner enhancedquantificationofretinalperfusionbyimproveddiscriminationofbloodflowfrombulkmotionsignalinocta
AT zhangmiao enhancedquantificationofretinalperfusionbyimproveddiscriminationofbloodflowfrombulkmotionsignalinocta
AT liuliang enhancedquantificationofretinalperfusionbyimproveddiscriminationofbloodflowfrombulkmotionsignalinocta
AT wangjie enhancedquantificationofretinalperfusionbyimproveddiscriminationofbloodflowfrombulkmotionsignalinocta
AT jiayali enhancedquantificationofretinalperfusionbyimproveddiscriminationofbloodflowfrombulkmotionsignalinocta
AT huangdavid enhancedquantificationofretinalperfusionbyimproveddiscriminationofbloodflowfrombulkmotionsignalinocta