Cargando…
Enhanced Quantification of Retinal Perfusion by Improved Discrimination of Blood Flow From Bulk Motion Signal in OCTA
PURPOSE: Quantification of optical coherence tomography angiography (OCTA) is confounded by the prevalence of bulk motion. We have previously developed a regression-based bulk motion subtraction (rb-BMS) algorithm that estimates bulk motion velocity and corrects for its effect on flow signal. Here,...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6284469/ https://www.ncbi.nlm.nih.gov/pubmed/30564509 http://dx.doi.org/10.1167/tvst.7.6.20 |
_version_ | 1783379340741836800 |
---|---|
author | Camino, Acner Zhang, Miao Liu, Liang Wang, Jie Jia, Yali Huang, David |
author_facet | Camino, Acner Zhang, Miao Liu, Liang Wang, Jie Jia, Yali Huang, David |
author_sort | Camino, Acner |
collection | PubMed |
description | PURPOSE: Quantification of optical coherence tomography angiography (OCTA) is confounded by the prevalence of bulk motion. We have previously developed a regression-based bulk motion subtraction (rb-BMS) algorithm that estimates bulk motion velocity and corrects for its effect on flow signal. Here, we aim to investigate its ability to improve the reliability of capillary density (CD) quantification. METHODS: Two spectral-domain systems (70-kHz Avanti/AngioVue and 68-kHz Cirrus/AngioPlex) acquired 6 × 6-mm OCTA scans. The rb-BMS algorithm was applied on each OCTA volume. Regression analysis of angiographic versus reflectance signal of avascular A-lines in B-frames was used to set an optimized reflectance-adjusted threshold for discriminating vascular versus nonvascular voxels. The CD was calculated from en face maximum projections of the superficial vascular complex in macular scans and the nerve fiber layer plexus in disc scans, excluding large vessels. The retinal signal strength (RSS) was calculated by averaging the logarithmic-scale OCT reflectance signal, and its correlation with CD was investigated. RESULTS: Eight healthy eyes were scanned with each instrument on 2 separate days. The rb-BMS algorithm improved within-visit repeatability and between-visit reproducibility of CD compared with a global-threshold measurement algorithm. Using the rb-BMS algorithm, the CD results were less affected by RSS and the population variation was reduced. Motion-induced line artifacts were also reduced. CONCLUSIONS: The rb-BMS algorithm improved the reliability of perfusion quantification in OCTA on both Food and Drug Administration–cleared spectral-domain OCTA systems. TRANSLATIONAL RELEVANCE: The rb-BMS method helped reduce the inter-scan variability by generating accurate vessel maps, improving the reliability of retinal perfusion quantification. |
format | Online Article Text |
id | pubmed-6284469 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Association for Research in Vision and Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-62844692018-12-18 Enhanced Quantification of Retinal Perfusion by Improved Discrimination of Blood Flow From Bulk Motion Signal in OCTA Camino, Acner Zhang, Miao Liu, Liang Wang, Jie Jia, Yali Huang, David Transl Vis Sci Technol Articles PURPOSE: Quantification of optical coherence tomography angiography (OCTA) is confounded by the prevalence of bulk motion. We have previously developed a regression-based bulk motion subtraction (rb-BMS) algorithm that estimates bulk motion velocity and corrects for its effect on flow signal. Here, we aim to investigate its ability to improve the reliability of capillary density (CD) quantification. METHODS: Two spectral-domain systems (70-kHz Avanti/AngioVue and 68-kHz Cirrus/AngioPlex) acquired 6 × 6-mm OCTA scans. The rb-BMS algorithm was applied on each OCTA volume. Regression analysis of angiographic versus reflectance signal of avascular A-lines in B-frames was used to set an optimized reflectance-adjusted threshold for discriminating vascular versus nonvascular voxels. The CD was calculated from en face maximum projections of the superficial vascular complex in macular scans and the nerve fiber layer plexus in disc scans, excluding large vessels. The retinal signal strength (RSS) was calculated by averaging the logarithmic-scale OCT reflectance signal, and its correlation with CD was investigated. RESULTS: Eight healthy eyes were scanned with each instrument on 2 separate days. The rb-BMS algorithm improved within-visit repeatability and between-visit reproducibility of CD compared with a global-threshold measurement algorithm. Using the rb-BMS algorithm, the CD results were less affected by RSS and the population variation was reduced. Motion-induced line artifacts were also reduced. CONCLUSIONS: The rb-BMS algorithm improved the reliability of perfusion quantification in OCTA on both Food and Drug Administration–cleared spectral-domain OCTA systems. TRANSLATIONAL RELEVANCE: The rb-BMS method helped reduce the inter-scan variability by generating accurate vessel maps, improving the reliability of retinal perfusion quantification. The Association for Research in Vision and Ophthalmology 2018-12-06 /pmc/articles/PMC6284469/ /pubmed/30564509 http://dx.doi.org/10.1167/tvst.7.6.20 Text en Copyright 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. |
spellingShingle | Articles Camino, Acner Zhang, Miao Liu, Liang Wang, Jie Jia, Yali Huang, David Enhanced Quantification of Retinal Perfusion by Improved Discrimination of Blood Flow From Bulk Motion Signal in OCTA |
title | Enhanced Quantification of Retinal Perfusion by Improved Discrimination of Blood Flow From Bulk Motion Signal in OCTA |
title_full | Enhanced Quantification of Retinal Perfusion by Improved Discrimination of Blood Flow From Bulk Motion Signal in OCTA |
title_fullStr | Enhanced Quantification of Retinal Perfusion by Improved Discrimination of Blood Flow From Bulk Motion Signal in OCTA |
title_full_unstemmed | Enhanced Quantification of Retinal Perfusion by Improved Discrimination of Blood Flow From Bulk Motion Signal in OCTA |
title_short | Enhanced Quantification of Retinal Perfusion by Improved Discrimination of Blood Flow From Bulk Motion Signal in OCTA |
title_sort | enhanced quantification of retinal perfusion by improved discrimination of blood flow from bulk motion signal in octa |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6284469/ https://www.ncbi.nlm.nih.gov/pubmed/30564509 http://dx.doi.org/10.1167/tvst.7.6.20 |
work_keys_str_mv | AT caminoacner enhancedquantificationofretinalperfusionbyimproveddiscriminationofbloodflowfrombulkmotionsignalinocta AT zhangmiao enhancedquantificationofretinalperfusionbyimproveddiscriminationofbloodflowfrombulkmotionsignalinocta AT liuliang enhancedquantificationofretinalperfusionbyimproveddiscriminationofbloodflowfrombulkmotionsignalinocta AT wangjie enhancedquantificationofretinalperfusionbyimproveddiscriminationofbloodflowfrombulkmotionsignalinocta AT jiayali enhancedquantificationofretinalperfusionbyimproveddiscriminationofbloodflowfrombulkmotionsignalinocta AT huangdavid enhancedquantificationofretinalperfusionbyimproveddiscriminationofbloodflowfrombulkmotionsignalinocta |