Cargando…

Ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms

The aim of this study was to evaluate and compare the diagnostic accuracy of B-mode, Doppler ultrasonography and Acoustic Radiation Force Impulse (ARFI) elastography in the identification of axillary and inguinal lymph nodes metastasis in bitches with mammary neoplasms. The axillary (n = 96) and ing...

Descripción completa

Detalles Bibliográficos
Autores principales: Silva, Priscila, Uscategui, Ricardo Andres Ramirez, Maronezi, Marjury Cristina, Gasser, Beatriz, Pavan, Letícia, Gatto, Igor Renan Honorato, de Almeida, Vivian Tavares, Vicente, Wilter Ricardo Russiano, Feliciano, Marcus Antônio Rossi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6286329/
https://www.ncbi.nlm.nih.gov/pubmed/30532025
http://dx.doi.org/10.1038/s41598-018-34806-9
_version_ 1783379430612140032
author Silva, Priscila
Uscategui, Ricardo Andres Ramirez
Maronezi, Marjury Cristina
Gasser, Beatriz
Pavan, Letícia
Gatto, Igor Renan Honorato
de Almeida, Vivian Tavares
Vicente, Wilter Ricardo Russiano
Feliciano, Marcus Antônio Rossi
author_facet Silva, Priscila
Uscategui, Ricardo Andres Ramirez
Maronezi, Marjury Cristina
Gasser, Beatriz
Pavan, Letícia
Gatto, Igor Renan Honorato
de Almeida, Vivian Tavares
Vicente, Wilter Ricardo Russiano
Feliciano, Marcus Antônio Rossi
author_sort Silva, Priscila
collection PubMed
description The aim of this study was to evaluate and compare the diagnostic accuracy of B-mode, Doppler ultrasonography and Acoustic Radiation Force Impulse (ARFI) elastography in the identification of axillary and inguinal lymph nodes metastasis in bitches with mammary neoplasms. The axillary (n = 96) and inguinal (n = 100) lymph nodes of 100 bitches were evaluated using B-Mode, Colour Doppler and ARFI-elastography. After this evaluation, mastectomy and lymph nodes excision were performed and these structures were histologically classified as free, reactive or metastatic. Ultrasonographic parameters were compared by Chi-Square or ANOVA tests and if they are significant, discriminative power analysis according to histopathological classification was performed (ROC analysis). The ARFI-elastography shear wave velocity (SWV) enabled metastasis identification in inguinal (sensitivity 95% specificity 87%) and axillary lymph nodes (sensitivity 100% specificity 94%). While B-Mode ultrasound Short/Long axis ratio evaluation of inguinal and axillary lymph nodes only resulted in a sensitivity around of 71% and specificity of 55%. In conclusion, B-Mode ultrasonography may contribute to diagnosis of metastasis in axillary and inguinal lymph nodes of bitches affected by mammary neoplasm with limited accuracy, while SWV evaluation proved to be an excellent diagnosis tool, which allows differentiation between free, reactive and tumour metastatic lymph nodes.
format Online
Article
Text
id pubmed-6286329
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-62863292018-12-19 Ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms Silva, Priscila Uscategui, Ricardo Andres Ramirez Maronezi, Marjury Cristina Gasser, Beatriz Pavan, Letícia Gatto, Igor Renan Honorato de Almeida, Vivian Tavares Vicente, Wilter Ricardo Russiano Feliciano, Marcus Antônio Rossi Sci Rep Article The aim of this study was to evaluate and compare the diagnostic accuracy of B-mode, Doppler ultrasonography and Acoustic Radiation Force Impulse (ARFI) elastography in the identification of axillary and inguinal lymph nodes metastasis in bitches with mammary neoplasms. The axillary (n = 96) and inguinal (n = 100) lymph nodes of 100 bitches were evaluated using B-Mode, Colour Doppler and ARFI-elastography. After this evaluation, mastectomy and lymph nodes excision were performed and these structures were histologically classified as free, reactive or metastatic. Ultrasonographic parameters were compared by Chi-Square or ANOVA tests and if they are significant, discriminative power analysis according to histopathological classification was performed (ROC analysis). The ARFI-elastography shear wave velocity (SWV) enabled metastasis identification in inguinal (sensitivity 95% specificity 87%) and axillary lymph nodes (sensitivity 100% specificity 94%). While B-Mode ultrasound Short/Long axis ratio evaluation of inguinal and axillary lymph nodes only resulted in a sensitivity around of 71% and specificity of 55%. In conclusion, B-Mode ultrasonography may contribute to diagnosis of metastasis in axillary and inguinal lymph nodes of bitches affected by mammary neoplasm with limited accuracy, while SWV evaluation proved to be an excellent diagnosis tool, which allows differentiation between free, reactive and tumour metastatic lymph nodes. Nature Publishing Group UK 2018-12-07 /pmc/articles/PMC6286329/ /pubmed/30532025 http://dx.doi.org/10.1038/s41598-018-34806-9 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Silva, Priscila
Uscategui, Ricardo Andres Ramirez
Maronezi, Marjury Cristina
Gasser, Beatriz
Pavan, Letícia
Gatto, Igor Renan Honorato
de Almeida, Vivian Tavares
Vicente, Wilter Ricardo Russiano
Feliciano, Marcus Antônio Rossi
Ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms
title Ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms
title_full Ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms
title_fullStr Ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms
title_full_unstemmed Ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms
title_short Ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms
title_sort ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6286329/
https://www.ncbi.nlm.nih.gov/pubmed/30532025
http://dx.doi.org/10.1038/s41598-018-34806-9
work_keys_str_mv AT silvapriscila ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms
AT uscateguiricardoandresramirez ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms
AT maronezimarjurycristina ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms
AT gasserbeatriz ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms
AT pavanleticia ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms
AT gattoigorrenanhonorato ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms
AT dealmeidaviviantavares ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms
AT vicentewilterricardorussiano ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms
AT felicianomarcusantoniorossi ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms