Cargando…
Ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms
The aim of this study was to evaluate and compare the diagnostic accuracy of B-mode, Doppler ultrasonography and Acoustic Radiation Force Impulse (ARFI) elastography in the identification of axillary and inguinal lymph nodes metastasis in bitches with mammary neoplasms. The axillary (n = 96) and ing...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6286329/ https://www.ncbi.nlm.nih.gov/pubmed/30532025 http://dx.doi.org/10.1038/s41598-018-34806-9 |
_version_ | 1783379430612140032 |
---|---|
author | Silva, Priscila Uscategui, Ricardo Andres Ramirez Maronezi, Marjury Cristina Gasser, Beatriz Pavan, Letícia Gatto, Igor Renan Honorato de Almeida, Vivian Tavares Vicente, Wilter Ricardo Russiano Feliciano, Marcus Antônio Rossi |
author_facet | Silva, Priscila Uscategui, Ricardo Andres Ramirez Maronezi, Marjury Cristina Gasser, Beatriz Pavan, Letícia Gatto, Igor Renan Honorato de Almeida, Vivian Tavares Vicente, Wilter Ricardo Russiano Feliciano, Marcus Antônio Rossi |
author_sort | Silva, Priscila |
collection | PubMed |
description | The aim of this study was to evaluate and compare the diagnostic accuracy of B-mode, Doppler ultrasonography and Acoustic Radiation Force Impulse (ARFI) elastography in the identification of axillary and inguinal lymph nodes metastasis in bitches with mammary neoplasms. The axillary (n = 96) and inguinal (n = 100) lymph nodes of 100 bitches were evaluated using B-Mode, Colour Doppler and ARFI-elastography. After this evaluation, mastectomy and lymph nodes excision were performed and these structures were histologically classified as free, reactive or metastatic. Ultrasonographic parameters were compared by Chi-Square or ANOVA tests and if they are significant, discriminative power analysis according to histopathological classification was performed (ROC analysis). The ARFI-elastography shear wave velocity (SWV) enabled metastasis identification in inguinal (sensitivity 95% specificity 87%) and axillary lymph nodes (sensitivity 100% specificity 94%). While B-Mode ultrasound Short/Long axis ratio evaluation of inguinal and axillary lymph nodes only resulted in a sensitivity around of 71% and specificity of 55%. In conclusion, B-Mode ultrasonography may contribute to diagnosis of metastasis in axillary and inguinal lymph nodes of bitches affected by mammary neoplasm with limited accuracy, while SWV evaluation proved to be an excellent diagnosis tool, which allows differentiation between free, reactive and tumour metastatic lymph nodes. |
format | Online Article Text |
id | pubmed-6286329 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-62863292018-12-19 Ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms Silva, Priscila Uscategui, Ricardo Andres Ramirez Maronezi, Marjury Cristina Gasser, Beatriz Pavan, Letícia Gatto, Igor Renan Honorato de Almeida, Vivian Tavares Vicente, Wilter Ricardo Russiano Feliciano, Marcus Antônio Rossi Sci Rep Article The aim of this study was to evaluate and compare the diagnostic accuracy of B-mode, Doppler ultrasonography and Acoustic Radiation Force Impulse (ARFI) elastography in the identification of axillary and inguinal lymph nodes metastasis in bitches with mammary neoplasms. The axillary (n = 96) and inguinal (n = 100) lymph nodes of 100 bitches were evaluated using B-Mode, Colour Doppler and ARFI-elastography. After this evaluation, mastectomy and lymph nodes excision were performed and these structures were histologically classified as free, reactive or metastatic. Ultrasonographic parameters were compared by Chi-Square or ANOVA tests and if they are significant, discriminative power analysis according to histopathological classification was performed (ROC analysis). The ARFI-elastography shear wave velocity (SWV) enabled metastasis identification in inguinal (sensitivity 95% specificity 87%) and axillary lymph nodes (sensitivity 100% specificity 94%). While B-Mode ultrasound Short/Long axis ratio evaluation of inguinal and axillary lymph nodes only resulted in a sensitivity around of 71% and specificity of 55%. In conclusion, B-Mode ultrasonography may contribute to diagnosis of metastasis in axillary and inguinal lymph nodes of bitches affected by mammary neoplasm with limited accuracy, while SWV evaluation proved to be an excellent diagnosis tool, which allows differentiation between free, reactive and tumour metastatic lymph nodes. Nature Publishing Group UK 2018-12-07 /pmc/articles/PMC6286329/ /pubmed/30532025 http://dx.doi.org/10.1038/s41598-018-34806-9 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Silva, Priscila Uscategui, Ricardo Andres Ramirez Maronezi, Marjury Cristina Gasser, Beatriz Pavan, Letícia Gatto, Igor Renan Honorato de Almeida, Vivian Tavares Vicente, Wilter Ricardo Russiano Feliciano, Marcus Antônio Rossi Ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms |
title | Ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms |
title_full | Ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms |
title_fullStr | Ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms |
title_full_unstemmed | Ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms |
title_short | Ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms |
title_sort | ultrasonography for lymph nodes metastasis identification in bitches with mammary neoplasms |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6286329/ https://www.ncbi.nlm.nih.gov/pubmed/30532025 http://dx.doi.org/10.1038/s41598-018-34806-9 |
work_keys_str_mv | AT silvapriscila ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms AT uscateguiricardoandresramirez ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms AT maronezimarjurycristina ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms AT gasserbeatriz ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms AT pavanleticia ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms AT gattoigorrenanhonorato ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms AT dealmeidaviviantavares ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms AT vicentewilterricardorussiano ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms AT felicianomarcusantoniorossi ultrasonographyforlymphnodesmetastasisidentificationinbitcheswithmammaryneoplasms |