Cargando…

Device updates successfully reduce T‑wave oversensing and inappropriate shocks in subcutaneous ICD patients

AIMS: To analyse the impact of device and software updates on the prevention of T‑wave oversensing (TWOS) and inappropriate shocks (IS) in subcutaneous ICD (S-ICD) patients. BACKGROUND: TWOS is a feared complication after implantation. It may lead to harmful IS. To date, specific strategies to reduc...

Descripción completa

Detalles Bibliográficos
Autores principales: Larbig, R., Motloch, L. J., Bettin, M., Fischer, A., Bode, N., Frommeyer, G., Loeher, A., Koebe, J., Reinke, F., Eckardt, L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bohn Stafleu van Loghum 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6288039/
https://www.ncbi.nlm.nih.gov/pubmed/30250998
http://dx.doi.org/10.1007/s12471-018-1160-y
_version_ 1783379722490609664
author Larbig, R.
Motloch, L. J.
Bettin, M.
Fischer, A.
Bode, N.
Frommeyer, G.
Loeher, A.
Koebe, J.
Reinke, F.
Eckardt, L.
author_facet Larbig, R.
Motloch, L. J.
Bettin, M.
Fischer, A.
Bode, N.
Frommeyer, G.
Loeher, A.
Koebe, J.
Reinke, F.
Eckardt, L.
author_sort Larbig, R.
collection PubMed
description AIMS: To analyse the impact of device and software updates on the prevention of T‑wave oversensing (TWOS) and inappropriate shocks (IS) in subcutaneous ICD (S-ICD) patients. BACKGROUND: TWOS is a feared complication after implantation. It may lead to harmful IS. To date, specific strategies to reduce these events are lacking. METHODS: In this retrospective single-centre trial we analysed 146 S‑ICD patients who were implanted between 2010 and 2016. In all eligible consecutive patients (n = 139), follow-up of at least 6 weeks was studied. The incidence of TWOS/IS was analysed in patients receiving a 2(nd) generation S‑ICD (Emblem-S-ICD) between 2014 and 2016 (Emblem). Their outcome was compared with a control group (SQ) treated with the SQ1010 device between 2010 and 2014, who were followed up for a maximum of 2 years. Furthermore, to test if the software update SMR8 reduces inappropriate shocks in the SQ1010-S-ICD population, the incidence of TWOS/IS was evaluated before and after update installation. RESULTS: Basic characteristics and indications for S‑ICD implantation were similar in both groups. However, the cumulative incidence of TWOS/IS was significantly decreased in Emblem vs. SQ (SQ: 15.4%, n = 14/91 vs. Emblem 4.2%, n = 2/48; p = 0.049). Furthermore, with regards to the SQ population we also observed a trend towards a significant reduction of TWOS/IS after installation of the software update SMR8 in 2014 (before update: 13.4%, n = 11/82 vs. after update: 4.6%, 3/65, p = 0.07). CONCLUSION: 2(nd) generation devices but probably also the SMR8 software update reduce the incidence of TWOS/IS in S‑ICD patients.
format Online
Article
Text
id pubmed-6288039
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Bohn Stafleu van Loghum
record_format MEDLINE/PubMed
spelling pubmed-62880392018-12-26 Device updates successfully reduce T‑wave oversensing and inappropriate shocks in subcutaneous ICD patients Larbig, R. Motloch, L. J. Bettin, M. Fischer, A. Bode, N. Frommeyer, G. Loeher, A. Koebe, J. Reinke, F. Eckardt, L. Neth Heart J Original Article AIMS: To analyse the impact of device and software updates on the prevention of T‑wave oversensing (TWOS) and inappropriate shocks (IS) in subcutaneous ICD (S-ICD) patients. BACKGROUND: TWOS is a feared complication after implantation. It may lead to harmful IS. To date, specific strategies to reduce these events are lacking. METHODS: In this retrospective single-centre trial we analysed 146 S‑ICD patients who were implanted between 2010 and 2016. In all eligible consecutive patients (n = 139), follow-up of at least 6 weeks was studied. The incidence of TWOS/IS was analysed in patients receiving a 2(nd) generation S‑ICD (Emblem-S-ICD) between 2014 and 2016 (Emblem). Their outcome was compared with a control group (SQ) treated with the SQ1010 device between 2010 and 2014, who were followed up for a maximum of 2 years. Furthermore, to test if the software update SMR8 reduces inappropriate shocks in the SQ1010-S-ICD population, the incidence of TWOS/IS was evaluated before and after update installation. RESULTS: Basic characteristics and indications for S‑ICD implantation were similar in both groups. However, the cumulative incidence of TWOS/IS was significantly decreased in Emblem vs. SQ (SQ: 15.4%, n = 14/91 vs. Emblem 4.2%, n = 2/48; p = 0.049). Furthermore, with regards to the SQ population we also observed a trend towards a significant reduction of TWOS/IS after installation of the software update SMR8 in 2014 (before update: 13.4%, n = 11/82 vs. after update: 4.6%, 3/65, p = 0.07). CONCLUSION: 2(nd) generation devices but probably also the SMR8 software update reduce the incidence of TWOS/IS in S‑ICD patients. Bohn Stafleu van Loghum 2018-09-24 2018-12 /pmc/articles/PMC6288039/ /pubmed/30250998 http://dx.doi.org/10.1007/s12471-018-1160-y Text en © The Author(s) 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Larbig, R.
Motloch, L. J.
Bettin, M.
Fischer, A.
Bode, N.
Frommeyer, G.
Loeher, A.
Koebe, J.
Reinke, F.
Eckardt, L.
Device updates successfully reduce T‑wave oversensing and inappropriate shocks in subcutaneous ICD patients
title Device updates successfully reduce T‑wave oversensing and inappropriate shocks in subcutaneous ICD patients
title_full Device updates successfully reduce T‑wave oversensing and inappropriate shocks in subcutaneous ICD patients
title_fullStr Device updates successfully reduce T‑wave oversensing and inappropriate shocks in subcutaneous ICD patients
title_full_unstemmed Device updates successfully reduce T‑wave oversensing and inappropriate shocks in subcutaneous ICD patients
title_short Device updates successfully reduce T‑wave oversensing and inappropriate shocks in subcutaneous ICD patients
title_sort device updates successfully reduce t‑wave oversensing and inappropriate shocks in subcutaneous icd patients
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6288039/
https://www.ncbi.nlm.nih.gov/pubmed/30250998
http://dx.doi.org/10.1007/s12471-018-1160-y
work_keys_str_mv AT larbigr deviceupdatessuccessfullyreducetwaveoversensingandinappropriateshocksinsubcutaneousicdpatients
AT motlochlj deviceupdatessuccessfullyreducetwaveoversensingandinappropriateshocksinsubcutaneousicdpatients
AT bettinm deviceupdatessuccessfullyreducetwaveoversensingandinappropriateshocksinsubcutaneousicdpatients
AT fischera deviceupdatessuccessfullyreducetwaveoversensingandinappropriateshocksinsubcutaneousicdpatients
AT boden deviceupdatessuccessfullyreducetwaveoversensingandinappropriateshocksinsubcutaneousicdpatients
AT frommeyerg deviceupdatessuccessfullyreducetwaveoversensingandinappropriateshocksinsubcutaneousicdpatients
AT loehera deviceupdatessuccessfullyreducetwaveoversensingandinappropriateshocksinsubcutaneousicdpatients
AT koebej deviceupdatessuccessfullyreducetwaveoversensingandinappropriateshocksinsubcutaneousicdpatients
AT reinkef deviceupdatessuccessfullyreducetwaveoversensingandinappropriateshocksinsubcutaneousicdpatients
AT eckardtl deviceupdatessuccessfullyreducetwaveoversensingandinappropriateshocksinsubcutaneousicdpatients