Cargando…
Plasma Orexin-A Levels Do Not Undergo Circadian Rhythm in Young Healthy Male Subjects
Orexin-A (OXA) has been originally isolated from a precursor peptide prepro-orexin from the lateral hypothalamus. The orexin system has been attributed to important functions in sleep, arousal and regulation of energy homeostasis. In addition to its high levels in cerebrospinal fluid, OXA is present...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6289979/ https://www.ncbi.nlm.nih.gov/pubmed/30568633 http://dx.doi.org/10.3389/fendo.2018.00710 |
_version_ | 1783380004234592256 |
---|---|
author | Mäkelä, Kari A. Karhu, Toni Jurado Acosta, Alicia Vakkuri, Olavi Leppäluoto, Juhani Herzig, Karl-Heinz |
author_facet | Mäkelä, Kari A. Karhu, Toni Jurado Acosta, Alicia Vakkuri, Olavi Leppäluoto, Juhani Herzig, Karl-Heinz |
author_sort | Mäkelä, Kari A. |
collection | PubMed |
description | Orexin-A (OXA) has been originally isolated from a precursor peptide prepro-orexin from the lateral hypothalamus. The orexin system has been attributed to important functions in sleep, arousal and regulation of energy homeostasis. In addition to its high levels in cerebrospinal fluid, OXA is present in blood. However, reported peptide concentrations in plasma vary significantly depending on the method used. Therefore, a specific and sensitive OXA radioimmunoassay (RIA) with solid phase extraction method was developed to determine whether plasma OXA concentrations is affected by acute feeding and/or wake and sleep in young healthy males. Blood samples were collected for 24 h from nine healthy males (aged 20–24 years; BMI 20.7–26.5) every 2 h starting at 11 a.m. Food was served at 12 p.m, 5:30 p.m, 8 p.m and 8 a.m and the sleep time was between 10 p.m and 7 a.m. Plasma samples were analyzed in addition for cortisol and melatonin levels. Blood pressure was monitored through the experimental period. OXA antibody was raised in rabbits. OXA antiserum had only minor cross-reactivity with prepro-orexin precursor (<0.001%), amino-terminal peptide (<0.001%), carboxy-terminal peptide (0.001%), and orexin-B (0.3%) with high sensitivity (0.15 pg/tube). Plasma OXA levels varied between 0.5 and 16 pg/ml in seven subjects and were undetectable (below 0.5 pg/ml) in two subjects. The OXA concentrations did not correlate to feeding nor wake/sleep, whereas cortisol, melatonin and mean arterial blood pressure presented a clear circadian rhythm in each subject. In conclusion, OXA is present in blood in low amounts and its levels do not follow autonomic nor neuroendocrine circadian rhythms. Thereby, studies examining regulatory mechanisms and influences of OXA from blood samples should interpret results very cautiously. |
format | Online Article Text |
id | pubmed-6289979 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-62899792018-12-19 Plasma Orexin-A Levels Do Not Undergo Circadian Rhythm in Young Healthy Male Subjects Mäkelä, Kari A. Karhu, Toni Jurado Acosta, Alicia Vakkuri, Olavi Leppäluoto, Juhani Herzig, Karl-Heinz Front Endocrinol (Lausanne) Endocrinology Orexin-A (OXA) has been originally isolated from a precursor peptide prepro-orexin from the lateral hypothalamus. The orexin system has been attributed to important functions in sleep, arousal and regulation of energy homeostasis. In addition to its high levels in cerebrospinal fluid, OXA is present in blood. However, reported peptide concentrations in plasma vary significantly depending on the method used. Therefore, a specific and sensitive OXA radioimmunoassay (RIA) with solid phase extraction method was developed to determine whether plasma OXA concentrations is affected by acute feeding and/or wake and sleep in young healthy males. Blood samples were collected for 24 h from nine healthy males (aged 20–24 years; BMI 20.7–26.5) every 2 h starting at 11 a.m. Food was served at 12 p.m, 5:30 p.m, 8 p.m and 8 a.m and the sleep time was between 10 p.m and 7 a.m. Plasma samples were analyzed in addition for cortisol and melatonin levels. Blood pressure was monitored through the experimental period. OXA antibody was raised in rabbits. OXA antiserum had only minor cross-reactivity with prepro-orexin precursor (<0.001%), amino-terminal peptide (<0.001%), carboxy-terminal peptide (0.001%), and orexin-B (0.3%) with high sensitivity (0.15 pg/tube). Plasma OXA levels varied between 0.5 and 16 pg/ml in seven subjects and were undetectable (below 0.5 pg/ml) in two subjects. The OXA concentrations did not correlate to feeding nor wake/sleep, whereas cortisol, melatonin and mean arterial blood pressure presented a clear circadian rhythm in each subject. In conclusion, OXA is present in blood in low amounts and its levels do not follow autonomic nor neuroendocrine circadian rhythms. Thereby, studies examining regulatory mechanisms and influences of OXA from blood samples should interpret results very cautiously. Frontiers Media S.A. 2018-12-05 /pmc/articles/PMC6289979/ /pubmed/30568633 http://dx.doi.org/10.3389/fendo.2018.00710 Text en Copyright © 2018 Mäkelä, Karhu, Jurado Acosta, Vakkuri, Leppäluoto and Herzig. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Endocrinology Mäkelä, Kari A. Karhu, Toni Jurado Acosta, Alicia Vakkuri, Olavi Leppäluoto, Juhani Herzig, Karl-Heinz Plasma Orexin-A Levels Do Not Undergo Circadian Rhythm in Young Healthy Male Subjects |
title | Plasma Orexin-A Levels Do Not Undergo Circadian Rhythm in Young Healthy Male Subjects |
title_full | Plasma Orexin-A Levels Do Not Undergo Circadian Rhythm in Young Healthy Male Subjects |
title_fullStr | Plasma Orexin-A Levels Do Not Undergo Circadian Rhythm in Young Healthy Male Subjects |
title_full_unstemmed | Plasma Orexin-A Levels Do Not Undergo Circadian Rhythm in Young Healthy Male Subjects |
title_short | Plasma Orexin-A Levels Do Not Undergo Circadian Rhythm in Young Healthy Male Subjects |
title_sort | plasma orexin-a levels do not undergo circadian rhythm in young healthy male subjects |
topic | Endocrinology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6289979/ https://www.ncbi.nlm.nih.gov/pubmed/30568633 http://dx.doi.org/10.3389/fendo.2018.00710 |
work_keys_str_mv | AT makelakaria plasmaorexinalevelsdonotundergocircadianrhythminyounghealthymalesubjects AT karhutoni plasmaorexinalevelsdonotundergocircadianrhythminyounghealthymalesubjects AT juradoacostaalicia plasmaorexinalevelsdonotundergocircadianrhythminyounghealthymalesubjects AT vakkuriolavi plasmaorexinalevelsdonotundergocircadianrhythminyounghealthymalesubjects AT leppaluotojuhani plasmaorexinalevelsdonotundergocircadianrhythminyounghealthymalesubjects AT herzigkarlheinz plasmaorexinalevelsdonotundergocircadianrhythminyounghealthymalesubjects |