Cargando…

Association between Frequency of Prosthesis Cleaning and the Discharge Characteristics and the Tear Film in Subjects with Anophthalmic Socket after Eviceration with Dermis Fat Graft

AIM: To analyze the associations between frequency of prosthesis cleaning with the discharge characteristics and the tear film in subjects with anophthalmic socket post evisceration with dermis fat graft. SUBJECTS AND METHODS: This study is an analytic observational with cross sectional design study...

Descripción completa

Detalles Bibliográficos
Autores principales: Adrian, Tari, Lubis, Rodiah Rahmawaty, Zubaidah, T Siti Harilza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Republic of Macedonia 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6290452/
https://www.ncbi.nlm.nih.gov/pubmed/30559852
http://dx.doi.org/10.3889/oamjms.2018.468
_version_ 1783380092216410112
author Adrian, Tari
Lubis, Rodiah Rahmawaty
Zubaidah, T Siti Harilza
author_facet Adrian, Tari
Lubis, Rodiah Rahmawaty
Zubaidah, T Siti Harilza
author_sort Adrian, Tari
collection PubMed
description AIM: To analyze the associations between frequency of prosthesis cleaning with the discharge characteristics and the tear film in subjects with anophthalmic socket post evisceration with dermis fat graft. SUBJECTS AND METHODS: This study is an analytic observational with cross sectional design study with control. The subjects of the study were unilateral acquired anophthalmic socket after evisceration with dermis fat graft at University of Sumatera Utara General Hospital which amounts to 30 subjects or 60 eyes (30 unilateral anophthalmic sockets, 30 contralateral eyes). Data was obtained from April 2018 to May 2018. RESULT: There is significant association between frequency of prosthesis cleaning and the frequency of discharge (P = 0.001) and tear film quantity (P = 0.024). There is also significant association between the tear film quantity and the frequency of discharge (P = 0.024). CONCLUSION: There was a significant association between frequency of prosthesis cleaning with the frequency of discharge and the tear film in subjects with Acquired Unilateral anophthalmic socket post-evisceration with dermis fat graft.
format Online
Article
Text
id pubmed-6290452
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Republic of Macedonia
record_format MEDLINE/PubMed
spelling pubmed-62904522018-12-17 Association between Frequency of Prosthesis Cleaning and the Discharge Characteristics and the Tear Film in Subjects with Anophthalmic Socket after Eviceration with Dermis Fat Graft Adrian, Tari Lubis, Rodiah Rahmawaty Zubaidah, T Siti Harilza Open Access Maced J Med Sci Basic Science AIM: To analyze the associations between frequency of prosthesis cleaning with the discharge characteristics and the tear film in subjects with anophthalmic socket post evisceration with dermis fat graft. SUBJECTS AND METHODS: This study is an analytic observational with cross sectional design study with control. The subjects of the study were unilateral acquired anophthalmic socket after evisceration with dermis fat graft at University of Sumatera Utara General Hospital which amounts to 30 subjects or 60 eyes (30 unilateral anophthalmic sockets, 30 contralateral eyes). Data was obtained from April 2018 to May 2018. RESULT: There is significant association between frequency of prosthesis cleaning and the frequency of discharge (P = 0.001) and tear film quantity (P = 0.024). There is also significant association between the tear film quantity and the frequency of discharge (P = 0.024). CONCLUSION: There was a significant association between frequency of prosthesis cleaning with the frequency of discharge and the tear film in subjects with Acquired Unilateral anophthalmic socket post-evisceration with dermis fat graft. Republic of Macedonia 2018-11-23 /pmc/articles/PMC6290452/ /pubmed/30559852 http://dx.doi.org/10.3889/oamjms.2018.468 Text en Copyright: © 2018 Tari Adrian, Rodiah Rahmawaty Lubis, T Siti Harilza Zubaidah. http://creativecommons.org/licenses/CC BY-NC/4.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0).
spellingShingle Basic Science
Adrian, Tari
Lubis, Rodiah Rahmawaty
Zubaidah, T Siti Harilza
Association between Frequency of Prosthesis Cleaning and the Discharge Characteristics and the Tear Film in Subjects with Anophthalmic Socket after Eviceration with Dermis Fat Graft
title Association between Frequency of Prosthesis Cleaning and the Discharge Characteristics and the Tear Film in Subjects with Anophthalmic Socket after Eviceration with Dermis Fat Graft
title_full Association between Frequency of Prosthesis Cleaning and the Discharge Characteristics and the Tear Film in Subjects with Anophthalmic Socket after Eviceration with Dermis Fat Graft
title_fullStr Association between Frequency of Prosthesis Cleaning and the Discharge Characteristics and the Tear Film in Subjects with Anophthalmic Socket after Eviceration with Dermis Fat Graft
title_full_unstemmed Association between Frequency of Prosthesis Cleaning and the Discharge Characteristics and the Tear Film in Subjects with Anophthalmic Socket after Eviceration with Dermis Fat Graft
title_short Association between Frequency of Prosthesis Cleaning and the Discharge Characteristics and the Tear Film in Subjects with Anophthalmic Socket after Eviceration with Dermis Fat Graft
title_sort association between frequency of prosthesis cleaning and the discharge characteristics and the tear film in subjects with anophthalmic socket after eviceration with dermis fat graft
topic Basic Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6290452/
https://www.ncbi.nlm.nih.gov/pubmed/30559852
http://dx.doi.org/10.3889/oamjms.2018.468
work_keys_str_mv AT adriantari associationbetweenfrequencyofprosthesiscleaningandthedischargecharacteristicsandthetearfilminsubjectswithanophthalmicsocketafterevicerationwithdermisfatgraft
AT lubisrodiahrahmawaty associationbetweenfrequencyofprosthesiscleaningandthedischargecharacteristicsandthetearfilminsubjectswithanophthalmicsocketafterevicerationwithdermisfatgraft
AT zubaidahtsitiharilza associationbetweenfrequencyofprosthesiscleaningandthedischargecharacteristicsandthetearfilminsubjectswithanophthalmicsocketafterevicerationwithdermisfatgraft