Spiroergometric measurements under increased inspiratory oxygen concentration (FIO2)—Putting the Haldane transformation to the test

Spiroergometric measurements of persons who require oxygen insufflation due to illness can be performed under conditions of increased inspiratory oxygen concentration (FIO(2)). This increase in FIO(2), however, often leads to errors in the calculation of oxygen consumption ([Image: see text] ). Thes...

Descripción completa

Detalles Bibliográficos
Autores principales: Lang, Stephan, Herold, Robert, Kraft, Alexander, Harth, Volker, Preisser, Alexandra M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6291083/
https://www.ncbi.nlm.nih.gov/pubmed/30540773
http://dx.doi.org/10.1371/journal.pone.0207648
_version_ 1783380198510559232
author Lang, Stephan
Herold, Robert
Kraft, Alexander
Harth, Volker
Preisser, Alexandra M.
author_facet Lang, Stephan
Herold, Robert
Kraft, Alexander
Harth, Volker
Preisser, Alexandra M.
author_sort Lang, Stephan
collection PubMed
description Spiroergometric measurements of persons who require oxygen insufflation due to illness can be performed under conditions of increased inspiratory oxygen concentration (FIO(2)). This increase in FIO(2), however, often leads to errors in the calculation of oxygen consumption ([Image: see text] ). These inconsistencies are due to the application of the Haldane Transformation (HT), an otherwise indispensable correction factor in the calculation of [Image: see text] that becomes inaccurate at higher FIO(2) concentrations. A possible solution to this problem could be the use of the ‘Eschenbacher transformation’ (ET) as an alternative correction factor. This study examines the concentration of FIO(2) at which the HT and the ET are valid, providing plausible data of oxygen consumption corresponding to the wattage achieved during cycle ergometry. Ten healthy volunteers underwent spiroergometric testing under standard conditions (FIO(2) = 20.9%), as well as at FIO(2) = 40% and 80%. When compared with the predicted values of [Image: see text] , as calculated according to Wasserman et al. (2012), the data obtained show that both the HT and ET are valid under normal conditions and at an increased FIO(2) of 40%. At FIO(2) concentrations of 80%, however, the [Image: see text] values provided by the HT begin to lose plausibility, whereas the ET continues to provide credible results. We conclude that the use of the ET in place of the HT in spiroergometric measurements with increased FIO(2) allows a reliable evaluation of stress tests in patients requiring high doses of supplemental oxygen.
format Online
Article
Text
id pubmed-6291083
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-62910832018-12-28 Spiroergometric measurements under increased inspiratory oxygen concentration (FIO2)—Putting the Haldane transformation to the test Lang, Stephan Herold, Robert Kraft, Alexander Harth, Volker Preisser, Alexandra M. PLoS One Research Article Spiroergometric measurements of persons who require oxygen insufflation due to illness can be performed under conditions of increased inspiratory oxygen concentration (FIO(2)). This increase in FIO(2), however, often leads to errors in the calculation of oxygen consumption ([Image: see text] ). These inconsistencies are due to the application of the Haldane Transformation (HT), an otherwise indispensable correction factor in the calculation of [Image: see text] that becomes inaccurate at higher FIO(2) concentrations. A possible solution to this problem could be the use of the ‘Eschenbacher transformation’ (ET) as an alternative correction factor. This study examines the concentration of FIO(2) at which the HT and the ET are valid, providing plausible data of oxygen consumption corresponding to the wattage achieved during cycle ergometry. Ten healthy volunteers underwent spiroergometric testing under standard conditions (FIO(2) = 20.9%), as well as at FIO(2) = 40% and 80%. When compared with the predicted values of [Image: see text] , as calculated according to Wasserman et al. (2012), the data obtained show that both the HT and ET are valid under normal conditions and at an increased FIO(2) of 40%. At FIO(2) concentrations of 80%, however, the [Image: see text] values provided by the HT begin to lose plausibility, whereas the ET continues to provide credible results. We conclude that the use of the ET in place of the HT in spiroergometric measurements with increased FIO(2) allows a reliable evaluation of stress tests in patients requiring high doses of supplemental oxygen. Public Library of Science 2018-12-12 /pmc/articles/PMC6291083/ /pubmed/30540773 http://dx.doi.org/10.1371/journal.pone.0207648 Text en © 2018 Lang et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Lang, Stephan
Herold, Robert
Kraft, Alexander
Harth, Volker
Preisser, Alexandra M.
Spiroergometric measurements under increased inspiratory oxygen concentration (FIO2)—Putting the Haldane transformation to the test
title Spiroergometric measurements under increased inspiratory oxygen concentration (FIO2)—Putting the Haldane transformation to the test
title_full Spiroergometric measurements under increased inspiratory oxygen concentration (FIO2)—Putting the Haldane transformation to the test
title_fullStr Spiroergometric measurements under increased inspiratory oxygen concentration (FIO2)—Putting the Haldane transformation to the test
title_full_unstemmed Spiroergometric measurements under increased inspiratory oxygen concentration (FIO2)—Putting the Haldane transformation to the test
title_short Spiroergometric measurements under increased inspiratory oxygen concentration (FIO2)—Putting the Haldane transformation to the test
title_sort spiroergometric measurements under increased inspiratory oxygen concentration (fio2)—putting the haldane transformation to the test
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6291083/
https://www.ncbi.nlm.nih.gov/pubmed/30540773
http://dx.doi.org/10.1371/journal.pone.0207648
work_keys_str_mv AT langstephan spiroergometricmeasurementsunderincreasedinspiratoryoxygenconcentrationfio2puttingthehaldanetransformationtothetest
AT heroldrobert spiroergometricmeasurementsunderincreasedinspiratoryoxygenconcentrationfio2puttingthehaldanetransformationtothetest
AT kraftalexander spiroergometricmeasurementsunderincreasedinspiratoryoxygenconcentrationfio2puttingthehaldanetransformationtothetest
AT harthvolker spiroergometricmeasurementsunderincreasedinspiratoryoxygenconcentrationfio2puttingthehaldanetransformationtothetest
AT preisseralexandram spiroergometricmeasurementsunderincreasedinspiratoryoxygenconcentrationfio2puttingthehaldanetransformationtothetest