Cargando…

Dynamic Switching of Helical Microgel Ribbons

[Image: see text] We report on a microscopic poly(N-isopropylacrylamide) hydrogel ribbon, coated by a thin gold layer, that shows helical coiling. Confined swelling and shrinkage of the hydrogel below and above its characteristic volume phase transition leads to a temperature actuated reversal of th...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Hang, Mourran, Ahmed, Möller, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2017
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6291182/
https://www.ncbi.nlm.nih.gov/pubmed/28181437
http://dx.doi.org/10.1021/acs.nanolett.7b00015
_version_ 1783380221903241216
author Zhang, Hang
Mourran, Ahmed
Möller, Martin
author_facet Zhang, Hang
Mourran, Ahmed
Möller, Martin
author_sort Zhang, Hang
collection PubMed
description [Image: see text] We report on a microscopic poly(N-isopropylacrylamide) hydrogel ribbon, coated by a thin gold layer, that shows helical coiling. Confined swelling and shrinkage of the hydrogel below and above its characteristic volume phase transition leads to a temperature actuated reversal of the sense of the helix. The extent and the shape of the winding are controlled by the dimensions and mechanical properties of the bilayer ribbon. We focus on a cylindrical helix geometry and monitor the morphing under equilibrium and nonequilibrium conditions, that is, when the temperature changes faster than the volume (millisecond range). For slow temperature variations, the water release and uptake follow the equilibrium transition trajectory determined by the time needed for the diffusion of water into and out of the microscopic gel. Much faster variations of the temperature are accomplished by internal heating of embedded gold nanorods by IR-light irradiation. This causes elastic stresses that strongly affect the motions. This method enables well-reproducible deviations from the equilibrium transition path and allows us to control rather precisely the spatiotemporal transformation in a cyclic repetitive process. Actuation and response are sensitive to small variations of temperature and composition of the aqueous sol in which the gel is immersed. The principle as described may be used to detect specific analytes that bind either to the surface of the gold layer or within the gel and can modify the interaction between the water and the gel. The reported nonequilibrium morphing implies that the system dissipates energy and may also be able to perform work as required for a microscopic motor.
format Online
Article
Text
id pubmed-6291182
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-62911822018-12-13 Dynamic Switching of Helical Microgel Ribbons Zhang, Hang Mourran, Ahmed Möller, Martin Nano Lett [Image: see text] We report on a microscopic poly(N-isopropylacrylamide) hydrogel ribbon, coated by a thin gold layer, that shows helical coiling. Confined swelling and shrinkage of the hydrogel below and above its characteristic volume phase transition leads to a temperature actuated reversal of the sense of the helix. The extent and the shape of the winding are controlled by the dimensions and mechanical properties of the bilayer ribbon. We focus on a cylindrical helix geometry and monitor the morphing under equilibrium and nonequilibrium conditions, that is, when the temperature changes faster than the volume (millisecond range). For slow temperature variations, the water release and uptake follow the equilibrium transition trajectory determined by the time needed for the diffusion of water into and out of the microscopic gel. Much faster variations of the temperature are accomplished by internal heating of embedded gold nanorods by IR-light irradiation. This causes elastic stresses that strongly affect the motions. This method enables well-reproducible deviations from the equilibrium transition path and allows us to control rather precisely the spatiotemporal transformation in a cyclic repetitive process. Actuation and response are sensitive to small variations of temperature and composition of the aqueous sol in which the gel is immersed. The principle as described may be used to detect specific analytes that bind either to the surface of the gold layer or within the gel and can modify the interaction between the water and the gel. The reported nonequilibrium morphing implies that the system dissipates energy and may also be able to perform work as required for a microscopic motor. American Chemical Society 2017-02-09 2017-03-08 /pmc/articles/PMC6291182/ /pubmed/28181437 http://dx.doi.org/10.1021/acs.nanolett.7b00015 Text en Copyright © 2017 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes.
spellingShingle Zhang, Hang
Mourran, Ahmed
Möller, Martin
Dynamic Switching of Helical Microgel Ribbons
title Dynamic Switching of Helical Microgel Ribbons
title_full Dynamic Switching of Helical Microgel Ribbons
title_fullStr Dynamic Switching of Helical Microgel Ribbons
title_full_unstemmed Dynamic Switching of Helical Microgel Ribbons
title_short Dynamic Switching of Helical Microgel Ribbons
title_sort dynamic switching of helical microgel ribbons
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6291182/
https://www.ncbi.nlm.nih.gov/pubmed/28181437
http://dx.doi.org/10.1021/acs.nanolett.7b00015
work_keys_str_mv AT zhanghang dynamicswitchingofhelicalmicrogelribbons
AT mourranahmed dynamicswitchingofhelicalmicrogelribbons
AT mollermartin dynamicswitchingofhelicalmicrogelribbons