Cargando…
Improved Peritoneal Cavity and Abdominal Organ Imaging Using a Biphasic Contrast Agent Protocol and Spectral Photon Counting Computed Tomography K-Edge Imaging
OBJECTIVES: To validate in vitro the capability of a high-spatial-resolution prototype spectral photon-counting computed tomography (SPCCT) scanner to differentiate between 2 contrast agents and to assess in vivo the image quality and the feasibility to image the peritoneal cavity in rats using the...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6291259/ https://www.ncbi.nlm.nih.gov/pubmed/29794948 http://dx.doi.org/10.1097/RLI.0000000000000483 |
_version_ | 1783380228963303424 |
---|---|
author | Si-Mohamed, Salim Thivolet, Arnaud Bonnot, Pierre-Emmanuel Bar-Ness, Daniel Képénékian, Vahan Cormode, David P. Douek, Philippe Rousset, Pascal |
author_facet | Si-Mohamed, Salim Thivolet, Arnaud Bonnot, Pierre-Emmanuel Bar-Ness, Daniel Képénékian, Vahan Cormode, David P. Douek, Philippe Rousset, Pascal |
author_sort | Si-Mohamed, Salim |
collection | PubMed |
description | OBJECTIVES: To validate in vitro the capability of a high-spatial-resolution prototype spectral photon-counting computed tomography (SPCCT) scanner to differentiate between 2 contrast agents and to assess in vivo the image quality and the feasibility to image the peritoneal cavity in rats using the 2 contrast agents simultaneously within the vascular and peritoneal compartments. MATERIALS AND METHODS: The authors performed SPCCT imaging (100 mAs, 120 kVp) with energy bin thresholds set to 30, 51, 64, 72, and 85 keV in vitro on a custom-made polyoxymethylene cylindrical phantom consisting of tubes with dilutions of both contrast agents and in vivo on 2 groups of adult rats using 2 injection protocols. Approval from the institutional animal ethics committee was obtained. One group received macrocylic gadolinium chelate intraperitoneal (IP) and iodine intravenous (IV) injections (protocol A, n = 3), whereas the second group received iodine IP and gadolinium IV (protocol B, n = 3). Helical scans were performed 35 minutes after IP injection and 20 seconds after IV injection. The SPCCT and contrast material images, that is, iodine and gadolinium maps, were reconstructed with a field of view of 160 mm, an isotropic voxel size of 250 μm, and a matrix size of 640 × 640 pixels using a soft reconstruction kernel. The SPCCT images were reconstructed with 2 different spatial resolutions to compare the image quality (sharpness, diagnostic quality, and organ visualization) of SPCCT (250 μm) with single-energy computed tomography (CT) (600 μm). Two radiologists evaluated the peritoneal opacification index in 13 regions (score = 0–3 per region) on each type of image. Concentrations of contrast agents were measured in the organs of interest. RESULTS: In vitro, the concentration measurements correlated well with the expected concentrations. The linear regressions both had R(2) values of 0.99, slopes of 0.84 and 0.87, and offsets at −0.52 and −0.38 mg/mL for iodine and gadolinium, respectively. In vivo, the SPCCT images were of better diagnostic quality, with increased sharpness compared with the CT-like images (P < 0.0001). Intraperitoneal diffusion was excellent, with similar peritoneal opacification index on SPCCT images and overlay of contrast material maps (P = 1) without a significant difference between protocol A (37.0 ± 1.7) and protocol B (35.3 ± 1.5) (P = 0.34). Only the contrast material maps demonstrated clear visual separation of the contrast agents, allowing specific quantification of the physiological enhancement in the liver, spleen, and kidney and the urinary clearance in the renal pelvis and bladder. Renal excretion of the contrast agents injected IP was observed and was consistent with blood diffusion. CONCLUSIONS: Spectral photon-counting CT can be used to perform a complete peritoneal dual-contrast protocol, enabling a good assessment of the peritoneal cavity and abdominal organs in rats. |
format | Online Article Text |
id | pubmed-6291259 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-62912592018-12-26 Improved Peritoneal Cavity and Abdominal Organ Imaging Using a Biphasic Contrast Agent Protocol and Spectral Photon Counting Computed Tomography K-Edge Imaging Si-Mohamed, Salim Thivolet, Arnaud Bonnot, Pierre-Emmanuel Bar-Ness, Daniel Képénékian, Vahan Cormode, David P. Douek, Philippe Rousset, Pascal Invest Radiol Original Articles OBJECTIVES: To validate in vitro the capability of a high-spatial-resolution prototype spectral photon-counting computed tomography (SPCCT) scanner to differentiate between 2 contrast agents and to assess in vivo the image quality and the feasibility to image the peritoneal cavity in rats using the 2 contrast agents simultaneously within the vascular and peritoneal compartments. MATERIALS AND METHODS: The authors performed SPCCT imaging (100 mAs, 120 kVp) with energy bin thresholds set to 30, 51, 64, 72, and 85 keV in vitro on a custom-made polyoxymethylene cylindrical phantom consisting of tubes with dilutions of both contrast agents and in vivo on 2 groups of adult rats using 2 injection protocols. Approval from the institutional animal ethics committee was obtained. One group received macrocylic gadolinium chelate intraperitoneal (IP) and iodine intravenous (IV) injections (protocol A, n = 3), whereas the second group received iodine IP and gadolinium IV (protocol B, n = 3). Helical scans were performed 35 minutes after IP injection and 20 seconds after IV injection. The SPCCT and contrast material images, that is, iodine and gadolinium maps, were reconstructed with a field of view of 160 mm, an isotropic voxel size of 250 μm, and a matrix size of 640 × 640 pixels using a soft reconstruction kernel. The SPCCT images were reconstructed with 2 different spatial resolutions to compare the image quality (sharpness, diagnostic quality, and organ visualization) of SPCCT (250 μm) with single-energy computed tomography (CT) (600 μm). Two radiologists evaluated the peritoneal opacification index in 13 regions (score = 0–3 per region) on each type of image. Concentrations of contrast agents were measured in the organs of interest. RESULTS: In vitro, the concentration measurements correlated well with the expected concentrations. The linear regressions both had R(2) values of 0.99, slopes of 0.84 and 0.87, and offsets at −0.52 and −0.38 mg/mL for iodine and gadolinium, respectively. In vivo, the SPCCT images were of better diagnostic quality, with increased sharpness compared with the CT-like images (P < 0.0001). Intraperitoneal diffusion was excellent, with similar peritoneal opacification index on SPCCT images and overlay of contrast material maps (P = 1) without a significant difference between protocol A (37.0 ± 1.7) and protocol B (35.3 ± 1.5) (P = 0.34). Only the contrast material maps demonstrated clear visual separation of the contrast agents, allowing specific quantification of the physiological enhancement in the liver, spleen, and kidney and the urinary clearance in the renal pelvis and bladder. Renal excretion of the contrast agents injected IP was observed and was consistent with blood diffusion. CONCLUSIONS: Spectral photon-counting CT can be used to perform a complete peritoneal dual-contrast protocol, enabling a good assessment of the peritoneal cavity and abdominal organs in rats. Lippincott Williams & Wilkins 2018-10 2018-05-23 /pmc/articles/PMC6291259/ /pubmed/29794948 http://dx.doi.org/10.1097/RLI.0000000000000483 Text en Copyright © 2018 The Author(s). Published by Wolters Kluwer Health, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. |
spellingShingle | Original Articles Si-Mohamed, Salim Thivolet, Arnaud Bonnot, Pierre-Emmanuel Bar-Ness, Daniel Képénékian, Vahan Cormode, David P. Douek, Philippe Rousset, Pascal Improved Peritoneal Cavity and Abdominal Organ Imaging Using a Biphasic Contrast Agent Protocol and Spectral Photon Counting Computed Tomography K-Edge Imaging |
title | Improved Peritoneal Cavity and Abdominal Organ Imaging Using a Biphasic Contrast Agent Protocol and Spectral Photon Counting Computed Tomography K-Edge Imaging |
title_full | Improved Peritoneal Cavity and Abdominal Organ Imaging Using a Biphasic Contrast Agent Protocol and Spectral Photon Counting Computed Tomography K-Edge Imaging |
title_fullStr | Improved Peritoneal Cavity and Abdominal Organ Imaging Using a Biphasic Contrast Agent Protocol and Spectral Photon Counting Computed Tomography K-Edge Imaging |
title_full_unstemmed | Improved Peritoneal Cavity and Abdominal Organ Imaging Using a Biphasic Contrast Agent Protocol and Spectral Photon Counting Computed Tomography K-Edge Imaging |
title_short | Improved Peritoneal Cavity and Abdominal Organ Imaging Using a Biphasic Contrast Agent Protocol and Spectral Photon Counting Computed Tomography K-Edge Imaging |
title_sort | improved peritoneal cavity and abdominal organ imaging using a biphasic contrast agent protocol and spectral photon counting computed tomography k-edge imaging |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6291259/ https://www.ncbi.nlm.nih.gov/pubmed/29794948 http://dx.doi.org/10.1097/RLI.0000000000000483 |
work_keys_str_mv | AT simohamedsalim improvedperitonealcavityandabdominalorganimagingusingabiphasiccontrastagentprotocolandspectralphotoncountingcomputedtomographykedgeimaging AT thivoletarnaud improvedperitonealcavityandabdominalorganimagingusingabiphasiccontrastagentprotocolandspectralphotoncountingcomputedtomographykedgeimaging AT bonnotpierreemmanuel improvedperitonealcavityandabdominalorganimagingusingabiphasiccontrastagentprotocolandspectralphotoncountingcomputedtomographykedgeimaging AT barnessdaniel improvedperitonealcavityandabdominalorganimagingusingabiphasiccontrastagentprotocolandspectralphotoncountingcomputedtomographykedgeimaging AT kepenekianvahan improvedperitonealcavityandabdominalorganimagingusingabiphasiccontrastagentprotocolandspectralphotoncountingcomputedtomographykedgeimaging AT cormodedavidp improvedperitonealcavityandabdominalorganimagingusingabiphasiccontrastagentprotocolandspectralphotoncountingcomputedtomographykedgeimaging AT douekphilippe improvedperitonealcavityandabdominalorganimagingusingabiphasiccontrastagentprotocolandspectralphotoncountingcomputedtomographykedgeimaging AT roussetpascal improvedperitonealcavityandabdominalorganimagingusingabiphasiccontrastagentprotocolandspectralphotoncountingcomputedtomographykedgeimaging |