Cargando…

An electrically-controlled programmable microfluidic concentration waveform generator

BACKGROUND: Biological systems have complicated environmental conditions that vary both spatially and temporally. It becomes necessary to impose time-varying soluble factor concentrations to study such systems, including cellular responses to pharmaceuticals, inflammation with waxing and waning cyto...

Descripción completa

Detalles Bibliográficos
Autores principales: Garrison, Joshua, Li, Zidong, Palanisamy, Barath, Wang, Ling, Seker, Erkin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6295081/
https://www.ncbi.nlm.nih.gov/pubmed/30564283
http://dx.doi.org/10.1186/s13036-018-0126-3
_version_ 1783380840347074560
author Garrison, Joshua
Li, Zidong
Palanisamy, Barath
Wang, Ling
Seker, Erkin
author_facet Garrison, Joshua
Li, Zidong
Palanisamy, Barath
Wang, Ling
Seker, Erkin
author_sort Garrison, Joshua
collection PubMed
description BACKGROUND: Biological systems have complicated environmental conditions that vary both spatially and temporally. It becomes necessary to impose time-varying soluble factor concentrations to study such systems, including cellular responses to pharmaceuticals, inflammation with waxing and waning cytokine concentrations, as well as circadian rhythms and their metabolic manifestations. There is therefore a need for platforms that can achieve time-varying concentrations with arbitrary waveforms. RESULTS: To address this need, we developed a microfluidic system that can deliver concentration waveforms in a fast and accurate manner by adopting concepts and tools from electrical engineering and fluid mechanics. Specifically, we employed pulse width modulation (PWM), a commonly used method for generating analog signals from digital sources. We implement this technique using three microfluidic components via laser ablation prototyping: low-pass filter (lower frequency signals permitted, high frequency signals blocked), resistor, and mixer. Each microfluidic component was individually studied and iteratively tuned to generate desired concentration waveforms with high accuracy. Using fluorescein as a small-molecule soluble factor surrogate, we demonstrated a series of concentration waveforms, including square, sawtooth, sinusoidal, and triangle waves with frequencies ranging from 100 mHz to 400 mHz. CONCLUSION: We reported the fabrication and characterization of microfluidic platform that can generate time-varying concentrations of fluorescein with arbitrary waveforms. We envision that this platform will enable a wide range of biological studies, where time-varying soluble factor concentrations play a critical role. In addition, the technology is expected to assist in the development of biomedical devices that allow precise dosing of pharmaceuticals for enhanced therapeutic efficacy and reduced toxicity. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13036-018-0126-3) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6295081
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-62950812018-12-18 An electrically-controlled programmable microfluidic concentration waveform generator Garrison, Joshua Li, Zidong Palanisamy, Barath Wang, Ling Seker, Erkin J Biol Eng Research BACKGROUND: Biological systems have complicated environmental conditions that vary both spatially and temporally. It becomes necessary to impose time-varying soluble factor concentrations to study such systems, including cellular responses to pharmaceuticals, inflammation with waxing and waning cytokine concentrations, as well as circadian rhythms and their metabolic manifestations. There is therefore a need for platforms that can achieve time-varying concentrations with arbitrary waveforms. RESULTS: To address this need, we developed a microfluidic system that can deliver concentration waveforms in a fast and accurate manner by adopting concepts and tools from electrical engineering and fluid mechanics. Specifically, we employed pulse width modulation (PWM), a commonly used method for generating analog signals from digital sources. We implement this technique using three microfluidic components via laser ablation prototyping: low-pass filter (lower frequency signals permitted, high frequency signals blocked), resistor, and mixer. Each microfluidic component was individually studied and iteratively tuned to generate desired concentration waveforms with high accuracy. Using fluorescein as a small-molecule soluble factor surrogate, we demonstrated a series of concentration waveforms, including square, sawtooth, sinusoidal, and triangle waves with frequencies ranging from 100 mHz to 400 mHz. CONCLUSION: We reported the fabrication and characterization of microfluidic platform that can generate time-varying concentrations of fluorescein with arbitrary waveforms. We envision that this platform will enable a wide range of biological studies, where time-varying soluble factor concentrations play a critical role. In addition, the technology is expected to assist in the development of biomedical devices that allow precise dosing of pharmaceuticals for enhanced therapeutic efficacy and reduced toxicity. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13036-018-0126-3) contains supplementary material, which is available to authorized users. BioMed Central 2018-12-14 /pmc/articles/PMC6295081/ /pubmed/30564283 http://dx.doi.org/10.1186/s13036-018-0126-3 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Garrison, Joshua
Li, Zidong
Palanisamy, Barath
Wang, Ling
Seker, Erkin
An electrically-controlled programmable microfluidic concentration waveform generator
title An electrically-controlled programmable microfluidic concentration waveform generator
title_full An electrically-controlled programmable microfluidic concentration waveform generator
title_fullStr An electrically-controlled programmable microfluidic concentration waveform generator
title_full_unstemmed An electrically-controlled programmable microfluidic concentration waveform generator
title_short An electrically-controlled programmable microfluidic concentration waveform generator
title_sort electrically-controlled programmable microfluidic concentration waveform generator
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6295081/
https://www.ncbi.nlm.nih.gov/pubmed/30564283
http://dx.doi.org/10.1186/s13036-018-0126-3
work_keys_str_mv AT garrisonjoshua anelectricallycontrolledprogrammablemicrofluidicconcentrationwaveformgenerator
AT lizidong anelectricallycontrolledprogrammablemicrofluidicconcentrationwaveformgenerator
AT palanisamybarath anelectricallycontrolledprogrammablemicrofluidicconcentrationwaveformgenerator
AT wangling anelectricallycontrolledprogrammablemicrofluidicconcentrationwaveformgenerator
AT sekererkin anelectricallycontrolledprogrammablemicrofluidicconcentrationwaveformgenerator
AT garrisonjoshua electricallycontrolledprogrammablemicrofluidicconcentrationwaveformgenerator
AT lizidong electricallycontrolledprogrammablemicrofluidicconcentrationwaveformgenerator
AT palanisamybarath electricallycontrolledprogrammablemicrofluidicconcentrationwaveformgenerator
AT wangling electricallycontrolledprogrammablemicrofluidicconcentrationwaveformgenerator
AT sekererkin electricallycontrolledprogrammablemicrofluidicconcentrationwaveformgenerator