Cargando…

Surgical outcomes associated with a sutureless drainage valve implantation procedure in patients with refractory glaucoma

PURPOSE: To evaluate the safety and efficacy profile of a sutureless procedure for drainage valve implantation with combined cataract removal and/or endoscopic cyclophotocoagulation (ECP). MATERIALS AND METHODS: A retrospective case series study of consecutive surgeries for Ahmed glaucoma valve (AGV...

Descripción completa

Detalles Bibliográficos
Autores principales: Pham, Caroline N, Radcliffe, Nathan M, Vu, Daniel M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6296183/
https://www.ncbi.nlm.nih.gov/pubmed/30587907
http://dx.doi.org/10.2147/OPTH.S186369
Descripción
Sumario:PURPOSE: To evaluate the safety and efficacy profile of a sutureless procedure for drainage valve implantation with combined cataract removal and/or endoscopic cyclophotocoagulation (ECP). MATERIALS AND METHODS: A retrospective case series study of consecutive surgeries for Ahmed glaucoma valve (AGV; New World Medical) implantation in a 1-year period was analyzed. The surgery was performed using a Tisseel fibrin sealant (Baxter Healthcare Corporation) in place of sutures. Some subsets within the case series also included a cataract extraction with intraocular lens (CEIOL) insertion and/or ECP (Endo Optiks) within the same procedure. Primary outcomes for this study including efficacy (IOP change, reduction in medications) and safety (complications and reoperations) were measured out to 3 years. Comparisons between subsets were made using ANOVA with post hoc Tukey’s pairwise tests. RESULTS: One hundred twenty-two eyes of 99 patients underwent sutureless AGV implantation surgery. Of the 122, 18 had an AGV implantation only, 46 had an AGV + CEIOL, 35 had an AGV + ECP, and 23 had an AGV + CEIOL + ECP. In total, there was a significant decrease in IOP (P<0.0001) and number of glaucoma medications (P≤0.0054) at each postoperative visit. In a one-way ANOVA, there were no significant differences in mean IOP between the different subsets of surgeries (P>0.05); 10.7% and 14.8% of eyes required a reoperation either for a complication or for uncontrolled glaucoma, respectively. CONCLUSION: Sutureless valve implantation is associated with a significant reduction in IOP percentage and medication use after the procedure with a safety profile comparable with other glaucoma surgeries.