Cargando…

Hemodynamic monitoring using thoracic bioimpedance – an optimal solution for the treatment of hypertension

Hypertension is a major issue of public health because of its increasing prevalence and multiple complications caused by failing to achieve an efficient blood pressure control. Considering hypertension as a hemodynamic disorder allows to prescribe a tailored therapy guided by individual hemodynamic...

Descripción completa

Detalles Bibliográficos
Autores principales: FARCAS, ANCA DANIELA, ANTON, FLORIN PETRU, MOCAN, MIHAELA, VIDA-SIMITI, LUMINITA ANIMARIE
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Iuliu Hatieganu University of Medicine and Pharmacy 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6296714/
https://www.ncbi.nlm.nih.gov/pubmed/30564027
http://dx.doi.org/10.15386/cjmed-1085
_version_ 1783381102156578816
author FARCAS, ANCA DANIELA
ANTON, FLORIN PETRU
MOCAN, MIHAELA
VIDA-SIMITI, LUMINITA ANIMARIE
author_facet FARCAS, ANCA DANIELA
ANTON, FLORIN PETRU
MOCAN, MIHAELA
VIDA-SIMITI, LUMINITA ANIMARIE
author_sort FARCAS, ANCA DANIELA
collection PubMed
description Hypertension is a major issue of public health because of its increasing prevalence and multiple complications caused by failing to achieve an efficient blood pressure control. Considering hypertension as a hemodynamic disorder allows to prescribe a tailored therapy guided by individual hemodynamic parameters, therefore leading to an increased rate of control. We present the case of a 59 years old diabetic, dyslipidemic and obese male who, although treated with 5 classes of antihypertensive drugs had uncontrolled hypertension that caused left ventricular failure. Using the HOTMAN system of hemodynamic monitoring using thoracic electrical bioimpedance allowed a quick identification of the cause and guided the therapy, achieving blood pressure control after 5 days of treatment. Treating hypertension by identifying the underlying hemodynamic imbalance allows prescribing a tailored therapy and shortens the initiation and stabilization phases of treatment.
format Online
Article
Text
id pubmed-6296714
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Iuliu Hatieganu University of Medicine and Pharmacy
record_format MEDLINE/PubMed
spelling pubmed-62967142018-12-18 Hemodynamic monitoring using thoracic bioimpedance – an optimal solution for the treatment of hypertension FARCAS, ANCA DANIELA ANTON, FLORIN PETRU MOCAN, MIHAELA VIDA-SIMITI, LUMINITA ANIMARIE Clujul Med Case Report Hypertension is a major issue of public health because of its increasing prevalence and multiple complications caused by failing to achieve an efficient blood pressure control. Considering hypertension as a hemodynamic disorder allows to prescribe a tailored therapy guided by individual hemodynamic parameters, therefore leading to an increased rate of control. We present the case of a 59 years old diabetic, dyslipidemic and obese male who, although treated with 5 classes of antihypertensive drugs had uncontrolled hypertension that caused left ventricular failure. Using the HOTMAN system of hemodynamic monitoring using thoracic electrical bioimpedance allowed a quick identification of the cause and guided the therapy, achieving blood pressure control after 5 days of treatment. Treating hypertension by identifying the underlying hemodynamic imbalance allows prescribing a tailored therapy and shortens the initiation and stabilization phases of treatment. Iuliu Hatieganu University of Medicine and Pharmacy 2018-10 2018-10-30 /pmc/articles/PMC6296714/ /pubmed/30564027 http://dx.doi.org/10.15386/cjmed-1085 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
spellingShingle Case Report
FARCAS, ANCA DANIELA
ANTON, FLORIN PETRU
MOCAN, MIHAELA
VIDA-SIMITI, LUMINITA ANIMARIE
Hemodynamic monitoring using thoracic bioimpedance – an optimal solution for the treatment of hypertension
title Hemodynamic monitoring using thoracic bioimpedance – an optimal solution for the treatment of hypertension
title_full Hemodynamic monitoring using thoracic bioimpedance – an optimal solution for the treatment of hypertension
title_fullStr Hemodynamic monitoring using thoracic bioimpedance – an optimal solution for the treatment of hypertension
title_full_unstemmed Hemodynamic monitoring using thoracic bioimpedance – an optimal solution for the treatment of hypertension
title_short Hemodynamic monitoring using thoracic bioimpedance – an optimal solution for the treatment of hypertension
title_sort hemodynamic monitoring using thoracic bioimpedance – an optimal solution for the treatment of hypertension
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6296714/
https://www.ncbi.nlm.nih.gov/pubmed/30564027
http://dx.doi.org/10.15386/cjmed-1085
work_keys_str_mv AT farcasancadaniela hemodynamicmonitoringusingthoracicbioimpedanceanoptimalsolutionforthetreatmentofhypertension
AT antonflorinpetru hemodynamicmonitoringusingthoracicbioimpedanceanoptimalsolutionforthetreatmentofhypertension
AT mocanmihaela hemodynamicmonitoringusingthoracicbioimpedanceanoptimalsolutionforthetreatmentofhypertension
AT vidasimitiluminitaanimarie hemodynamicmonitoringusingthoracicbioimpedanceanoptimalsolutionforthetreatmentofhypertension