Cargando…

Evaluation of Analytical Performance of Variant II Turbo HbA1c Analyzer According to Sigma Metrics

BACKGROUND: Hemoglobin A1c, (HbA1c) which is the major constituent of glycated hemoglobin, has been used in the follow-up of retrospective glycemia for years and in the diagnosis of diabetes mellitus nowadays. Since the analytical performance of HbA1c should be high likewise all laboratory tests, va...

Descripción completa

Detalles Bibliográficos
Autores principales: Bozkaya, Giray, Uzuncan, Nuriye, Bilgili, Sibel, Demirezen, Ozlem
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sciendo 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6298457/
https://www.ncbi.nlm.nih.gov/pubmed/30820181
http://dx.doi.org/10.2478/jomb-2018-0014
_version_ 1783381320612708352
author Bozkaya, Giray
Uzuncan, Nuriye
Bilgili, Sibel
Demirezen, Ozlem
author_facet Bozkaya, Giray
Uzuncan, Nuriye
Bilgili, Sibel
Demirezen, Ozlem
author_sort Bozkaya, Giray
collection PubMed
description BACKGROUND: Hemoglobin A1c, (HbA1c) which is the major constituent of glycated hemoglobin, has been used in the follow-up of retrospective glycemia for years and in the diagnosis of diabetes mellitus nowadays. Since the analytical performance of HbA1c should be high likewise all laboratory tests, various quality control measures are used. Sigma metrics is one of these measures and it is the combination of bias, precision and total allowable error that ensures a general evaluation of analytical quality. The aim of our study was to evaluate the analytical performance of Bio-Rad’s Variant Turbo II HbA1c analyzer according to sigma metrics. METHODS: Sigma levels were calculated using the data obtained from two levels of internal and 12 external quality control materials (Bio-Rad) of Variant II Turbo HbA1c analyzer according to σ = (TEa% - Bias%) / CV% formula. RESULTS: The mean sigma levels for low and high quality control materials were found to be 3.0 and 4.1, respectively. CONCLUSIONS: The annual mean analytical performance of Variant II Turbo HbA1c analyzer was found to be acceptable according to sigma metrics. In order to be sure of the difference in HbA1c results indicating the success or failure in treatment but not arise from analytical variation, it is thought that more stringent quality control measures should be applied to reach higher sigma levels.
format Online
Article
Text
id pubmed-6298457
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Sciendo
record_format MEDLINE/PubMed
spelling pubmed-62984572019-03-01 Evaluation of Analytical Performance of Variant II Turbo HbA1c Analyzer According to Sigma Metrics Bozkaya, Giray Uzuncan, Nuriye Bilgili, Sibel Demirezen, Ozlem J Med Biochem Original Paper BACKGROUND: Hemoglobin A1c, (HbA1c) which is the major constituent of glycated hemoglobin, has been used in the follow-up of retrospective glycemia for years and in the diagnosis of diabetes mellitus nowadays. Since the analytical performance of HbA1c should be high likewise all laboratory tests, various quality control measures are used. Sigma metrics is one of these measures and it is the combination of bias, precision and total allowable error that ensures a general evaluation of analytical quality. The aim of our study was to evaluate the analytical performance of Bio-Rad’s Variant Turbo II HbA1c analyzer according to sigma metrics. METHODS: Sigma levels were calculated using the data obtained from two levels of internal and 12 external quality control materials (Bio-Rad) of Variant II Turbo HbA1c analyzer according to σ = (TEa% - Bias%) / CV% formula. RESULTS: The mean sigma levels for low and high quality control materials were found to be 3.0 and 4.1, respectively. CONCLUSIONS: The annual mean analytical performance of Variant II Turbo HbA1c analyzer was found to be acceptable according to sigma metrics. In order to be sure of the difference in HbA1c results indicating the success or failure in treatment but not arise from analytical variation, it is thought that more stringent quality control measures should be applied to reach higher sigma levels. Sciendo 2019-03-01 /pmc/articles/PMC6298457/ /pubmed/30820181 http://dx.doi.org/10.2478/jomb-2018-0014 Text en © 2019 Giray Bozkaya, Nuriye Uzuncan, Sibel Bilgili, Ozlem Demirezen published by Sciendo http://creativecommons.org/licenses/by-nc-nd/3.0 This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
spellingShingle Original Paper
Bozkaya, Giray
Uzuncan, Nuriye
Bilgili, Sibel
Demirezen, Ozlem
Evaluation of Analytical Performance of Variant II Turbo HbA1c Analyzer According to Sigma Metrics
title Evaluation of Analytical Performance of Variant II Turbo HbA1c Analyzer According to Sigma Metrics
title_full Evaluation of Analytical Performance of Variant II Turbo HbA1c Analyzer According to Sigma Metrics
title_fullStr Evaluation of Analytical Performance of Variant II Turbo HbA1c Analyzer According to Sigma Metrics
title_full_unstemmed Evaluation of Analytical Performance of Variant II Turbo HbA1c Analyzer According to Sigma Metrics
title_short Evaluation of Analytical Performance of Variant II Turbo HbA1c Analyzer According to Sigma Metrics
title_sort evaluation of analytical performance of variant ii turbo hba1c analyzer according to sigma metrics
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6298457/
https://www.ncbi.nlm.nih.gov/pubmed/30820181
http://dx.doi.org/10.2478/jomb-2018-0014
work_keys_str_mv AT bozkayagiray evaluationofanalyticalperformanceofvariantiiturbohba1canalyzeraccordingtosigmametrics
AT uzuncannuriye evaluationofanalyticalperformanceofvariantiiturbohba1canalyzeraccordingtosigmametrics
AT bilgilisibel evaluationofanalyticalperformanceofvariantiiturbohba1canalyzeraccordingtosigmametrics
AT demirezenozlem evaluationofanalyticalperformanceofvariantiiturbohba1canalyzeraccordingtosigmametrics