Effects of laser treatments on surface roughness of zirconium oxide ceramics

BACKGROUND: The aim of this study was to analyze the surface roughness of yttrium stabilized tetragonal polycrystalline zirconia (Y-TZP) ceramics after different laser treatments (CO(2,) ER: YAG). METHODS: 5x5x2 mm rectangular prisms of forty eight Y-TZP (Zirkonzahn) ceramic specimens were prepared....

Descripción completa

Detalles Bibliográficos
Autores principales: Ergun Kunt, Goknil, Duran, Ibrahim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6300027/
https://www.ncbi.nlm.nih.gov/pubmed/30567536
http://dx.doi.org/10.1186/s12903-018-0688-y
_version_ 1783381611786534912
author Ergun Kunt, Goknil
Duran, Ibrahim
author_facet Ergun Kunt, Goknil
Duran, Ibrahim
author_sort Ergun Kunt, Goknil
collection PubMed
description BACKGROUND: The aim of this study was to analyze the surface roughness of yttrium stabilized tetragonal polycrystalline zirconia (Y-TZP) ceramics after different laser treatments (CO(2,) ER: YAG). METHODS: 5x5x2 mm rectangular prisms of forty eight Y-TZP (Zirkonzahn) ceramic specimens were prepared. In order to standardize surfaces, 600-, 1200- grid silicon carbide papers were used to gradually ground wet on 300 rpm grinding machine for 10 s. Eight groups (n = 6) were randomly formed from the specimens of each ceramic as control (GroupC), sandblasted (GroupS), two different CO(2) laser treatments (Group3W: 3 W and 382 w/cal, Group4W: 4 W and 509w/cal) and four different Er: YAG laser treatments (Group150SP: 150 mJ and 10-Hz with 100μS; Group150SSP: 150 mJ and 10-Hz with 300μS; Group300SP: 300 mJ and 10-Hz with 100μS; Group300SSP: 300 mJ and 10-Hz with 300μS). A profilometer was used to conduct surface roughness measurements (Ra). Surface morphologies of the specimens were evaluated under SEM after laser treatment. RESULTS: To analyze the data one-way ANOVA and to compare the mean values Tukey HSD tests (α = .05) were used. One - way ANOVA results showed that Group S had the highest Ra value and Group150 SP had the lowest. After sandblasting group the highest value was seen in Group4W. There were no statistically significant differences among Group C, Group3W, Group150SSP, Group300SP, and Group300SSP. CONCLUSIONS: The study showed that surface roughness of zirconium oxide ceramics was increased with CO2 laser.
format Online
Article
Text
id pubmed-6300027
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-63000272018-12-20 Effects of laser treatments on surface roughness of zirconium oxide ceramics Ergun Kunt, Goknil Duran, Ibrahim BMC Oral Health Research Article BACKGROUND: The aim of this study was to analyze the surface roughness of yttrium stabilized tetragonal polycrystalline zirconia (Y-TZP) ceramics after different laser treatments (CO(2,) ER: YAG). METHODS: 5x5x2 mm rectangular prisms of forty eight Y-TZP (Zirkonzahn) ceramic specimens were prepared. In order to standardize surfaces, 600-, 1200- grid silicon carbide papers were used to gradually ground wet on 300 rpm grinding machine for 10 s. Eight groups (n = 6) were randomly formed from the specimens of each ceramic as control (GroupC), sandblasted (GroupS), two different CO(2) laser treatments (Group3W: 3 W and 382 w/cal, Group4W: 4 W and 509w/cal) and four different Er: YAG laser treatments (Group150SP: 150 mJ and 10-Hz with 100μS; Group150SSP: 150 mJ and 10-Hz with 300μS; Group300SP: 300 mJ and 10-Hz with 100μS; Group300SSP: 300 mJ and 10-Hz with 300μS). A profilometer was used to conduct surface roughness measurements (Ra). Surface morphologies of the specimens were evaluated under SEM after laser treatment. RESULTS: To analyze the data one-way ANOVA and to compare the mean values Tukey HSD tests (α = .05) were used. One - way ANOVA results showed that Group S had the highest Ra value and Group150 SP had the lowest. After sandblasting group the highest value was seen in Group4W. There were no statistically significant differences among Group C, Group3W, Group150SSP, Group300SP, and Group300SSP. CONCLUSIONS: The study showed that surface roughness of zirconium oxide ceramics was increased with CO2 laser. BioMed Central 2018-12-19 /pmc/articles/PMC6300027/ /pubmed/30567536 http://dx.doi.org/10.1186/s12903-018-0688-y Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Ergun Kunt, Goknil
Duran, Ibrahim
Effects of laser treatments on surface roughness of zirconium oxide ceramics
title Effects of laser treatments on surface roughness of zirconium oxide ceramics
title_full Effects of laser treatments on surface roughness of zirconium oxide ceramics
title_fullStr Effects of laser treatments on surface roughness of zirconium oxide ceramics
title_full_unstemmed Effects of laser treatments on surface roughness of zirconium oxide ceramics
title_short Effects of laser treatments on surface roughness of zirconium oxide ceramics
title_sort effects of laser treatments on surface roughness of zirconium oxide ceramics
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6300027/
https://www.ncbi.nlm.nih.gov/pubmed/30567536
http://dx.doi.org/10.1186/s12903-018-0688-y
work_keys_str_mv AT ergunkuntgoknil effectsoflasertreatmentsonsurfaceroughnessofzirconiumoxideceramics
AT duranibrahim effectsoflasertreatmentsonsurfaceroughnessofzirconiumoxideceramics