Military trainees can accurately measure optic nerve sheath diameter after a brief training session
BACKGROUND: Identification of elevated intracranial pressure is important following traumatic brain injury. We assessed the feasibility of educating military trainees on accurately obtaining optic nerve sheath diameter measurements using a brief didactic and hands-on training session. Optic nerve sh...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6300875/ https://www.ncbi.nlm.nih.gov/pubmed/30572931 http://dx.doi.org/10.1186/s40779-018-0189-y |
_version_ | 1783381759349489664 |
---|---|
author | Betcher, Joseph Becker, Torben K. Stoyanoff, Peter Cranford, Jim Theyyunni, Nik |
author_facet | Betcher, Joseph Becker, Torben K. Stoyanoff, Peter Cranford, Jim Theyyunni, Nik |
author_sort | Betcher, Joseph |
collection | PubMed |
description | BACKGROUND: Identification of elevated intracranial pressure is important following traumatic brain injury. We assessed the feasibility of educating military trainees on accurately obtaining optic nerve sheath diameter measurements using a brief didactic and hands-on training session. Optic nerve sheath diameter is a noninvasive surrogate marker for elevated intracranial pressure, and may be of value in remote military operations, where rapid triage decisions must be made without access to advanced medical equipment. METHODS: Military trainees with minimal ultrasound experience were given a 5-min didactic presentation on optic nerve sheath diameter ultrasound. Trainees practiced optic nerve sheath diameter measurements guided by emergency physician ultrasound experts. Trainees then measured the optic nerve sheath diameter on normal volunteers. Following this, a trained physician measured the optic nerve sheath diameter on the same volunteer as a criterion standard. An average of three measurements was taken. RESULTS: Twenty-three military trainees were enrolled. A mixed design ANOVA was used to compare measurements by trainees to those of physicians, with a mean difference of − 0.6 mm (P = 0.76). A Bland-Altman analysis showed that the degree of bias in optic nerve sheath diameter measures provided by trainees was very small: d = − 0.004 for the right eye and d = − 0.007 for the left eye. CONCLUSION: This study demonstrates that optic nerve sheath diameter measurement can be accurately performed by novice ultrasonographers after a brief training session. If validated, point-of-care optic nerve sheath diameter measurement could impact the triage of injured patients in remote areas. |
format | Online Article Text |
id | pubmed-6300875 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-63008752018-12-31 Military trainees can accurately measure optic nerve sheath diameter after a brief training session Betcher, Joseph Becker, Torben K. Stoyanoff, Peter Cranford, Jim Theyyunni, Nik Mil Med Res Research BACKGROUND: Identification of elevated intracranial pressure is important following traumatic brain injury. We assessed the feasibility of educating military trainees on accurately obtaining optic nerve sheath diameter measurements using a brief didactic and hands-on training session. Optic nerve sheath diameter is a noninvasive surrogate marker for elevated intracranial pressure, and may be of value in remote military operations, where rapid triage decisions must be made without access to advanced medical equipment. METHODS: Military trainees with minimal ultrasound experience were given a 5-min didactic presentation on optic nerve sheath diameter ultrasound. Trainees practiced optic nerve sheath diameter measurements guided by emergency physician ultrasound experts. Trainees then measured the optic nerve sheath diameter on normal volunteers. Following this, a trained physician measured the optic nerve sheath diameter on the same volunteer as a criterion standard. An average of three measurements was taken. RESULTS: Twenty-three military trainees were enrolled. A mixed design ANOVA was used to compare measurements by trainees to those of physicians, with a mean difference of − 0.6 mm (P = 0.76). A Bland-Altman analysis showed that the degree of bias in optic nerve sheath diameter measures provided by trainees was very small: d = − 0.004 for the right eye and d = − 0.007 for the left eye. CONCLUSION: This study demonstrates that optic nerve sheath diameter measurement can be accurately performed by novice ultrasonographers after a brief training session. If validated, point-of-care optic nerve sheath diameter measurement could impact the triage of injured patients in remote areas. BioMed Central 2018-12-20 /pmc/articles/PMC6300875/ /pubmed/30572931 http://dx.doi.org/10.1186/s40779-018-0189-y Text en © The Author(s). 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Betcher, Joseph Becker, Torben K. Stoyanoff, Peter Cranford, Jim Theyyunni, Nik Military trainees can accurately measure optic nerve sheath diameter after a brief training session |
title | Military trainees can accurately measure optic nerve sheath diameter after a brief training session |
title_full | Military trainees can accurately measure optic nerve sheath diameter after a brief training session |
title_fullStr | Military trainees can accurately measure optic nerve sheath diameter after a brief training session |
title_full_unstemmed | Military trainees can accurately measure optic nerve sheath diameter after a brief training session |
title_short | Military trainees can accurately measure optic nerve sheath diameter after a brief training session |
title_sort | military trainees can accurately measure optic nerve sheath diameter after a brief training session |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6300875/ https://www.ncbi.nlm.nih.gov/pubmed/30572931 http://dx.doi.org/10.1186/s40779-018-0189-y |
work_keys_str_mv | AT betcherjoseph militarytraineescanaccuratelymeasureopticnervesheathdiameterafterabrieftrainingsession AT beckertorbenk militarytraineescanaccuratelymeasureopticnervesheathdiameterafterabrieftrainingsession AT stoyanoffpeter militarytraineescanaccuratelymeasureopticnervesheathdiameterafterabrieftrainingsession AT cranfordjim militarytraineescanaccuratelymeasureopticnervesheathdiameterafterabrieftrainingsession AT theyyunninik militarytraineescanaccuratelymeasureopticnervesheathdiameterafterabrieftrainingsession |