Cuff Technique for Small-Diameter Vascular Grafts in the Systemic Arterial Circulation of the Rat

This study determined the feasibility of the cuff technique for small-caliber vascular grafts in a rat model. A graft was implanted with the cuff technique or suture technique in a 1-cm segment of the abdominal aorta in 12 rats. The mean aortic clamp time was 29 minutes with the cuff technique and 4...

Descripción completa

Detalles Bibliográficos
Autores principales: Cho, Sukki, Song, In Hag
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Thoracic and Cardiovascular Surgery 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6301317/
https://www.ncbi.nlm.nih.gov/pubmed/30588455
http://dx.doi.org/10.5090/kjtcs.2018.51.6.423
Descripción
Sumario:This study determined the feasibility of the cuff technique for small-caliber vascular grafts in a rat model. A graft was implanted with the cuff technique or suture technique in a 1-cm segment of the abdominal aorta in 12 rats. The mean aortic clamp time was 29 minutes with the cuff technique and 44 minutes with the suture technique; the cuff technique was significantly shorter. Abdominal angiography at 1 week after implantation showed no significant stenosis in 9 rats, focal stenosis of the mid-portion of the graft in 1 rat with each technique, and total occlusion of the graft in 1 rat with the suture technique. We have successfully used the cuff technique for anastomosis for small-caliber vascular grafts in an animal model.