Cargando…
Towards international standardization of immunoassays for Müllerian inhibiting substance/anti-Müllerian hormone
RESEARCH QUESTION: Is formulated and lyophilized, recombinant human Müllerian inhibiting substance, also known as anti-Müllerian hormone (AMH), suitable for the preparation of a WHO international standard to calibrate AMH immunoassays? DESIGN: The AMH content of a trial preparation, coded SS-581, wa...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6302068/ https://www.ncbi.nlm.nih.gov/pubmed/30241771 http://dx.doi.org/10.1016/j.rbmo.2018.08.012 |
Sumario: | RESEARCH QUESTION: Is formulated and lyophilized, recombinant human Müllerian inhibiting substance, also known as anti-Müllerian hormone (AMH), suitable for the preparation of a WHO international standard to calibrate AMH immunoassays? DESIGN: The AMH content of a trial preparation, coded SS-581, was determined by five laboratories using seven immunoassay methods. Participants were requested to report the content of the preparation in terms of their method calibrators through the measurement of a minimum of five concentrations in the linear part of the dose-response curve. Participants were also asked to measure, concomitantly, a panel of six serum samples containing AMH at concentrations of 0.1–13.0 ng/ml. RESULTS: Across all assays, including two automated assays in development, the geometric mean content was 361.76 ng/ampoule with a geometric coefficient of variation (GCV%) of 39.95%. When measured by immunoassays that were commercially available at the time of the study, the mean content was 423.08 ng/ampoule, with a GCV% of 26.67%. The inter-method geometric means of five serum samples with an AMH concentration >0.3 ng/ml and measured concomitantly with dilutions of SS-581 varied with a range of GCV% of 14.90–22.35%, which may reflect the use of serum sample value transfer to calibrate current immunoassays, some of which use non-human AMH calibrators. The AMH in trial preparation SS-581 was shown to be biologically active in the Müllerian duct regression assay. CONCLUSIONS: A reference material prepared using human recombinant AMH is a promising candidate for the preparation of an international standard for AMH for immunoassays calibrated to recombinant human AMH. |
---|