Cargando…

Injectable Bulking Agent to Treat Postprostatectomy Urinary Incontinence: A Safety and Effectiveness Pilot Study

OBJECTIVES: To evaluate the safety and effectiveness of the injectable bulking agent Opsys® (Promedon, Cordoba, Argentina) for treating minimal postprostatectomy stress urinary incontinence (SUI). PATIENTS AND METHODS: Single-centre, pilot study on ten male patients with SUI, < 30 g urine loss/ 2...

Descripción completa

Detalles Bibliográficos
Autores principales: van Uhm, Janneke I. M., Vermeer, Marloes, Elzevier, Henk W., Noordzij, Joop W., Koldewijn, Evert L., Cornel, Erik B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6304605/
https://www.ncbi.nlm.nih.gov/pubmed/30627546
http://dx.doi.org/10.1155/2018/2796967
_version_ 1783382399080464384
author van Uhm, Janneke I. M.
Vermeer, Marloes
Elzevier, Henk W.
Noordzij, Joop W.
Koldewijn, Evert L.
Cornel, Erik B.
author_facet van Uhm, Janneke I. M.
Vermeer, Marloes
Elzevier, Henk W.
Noordzij, Joop W.
Koldewijn, Evert L.
Cornel, Erik B.
author_sort van Uhm, Janneke I. M.
collection PubMed
description OBJECTIVES: To evaluate the safety and effectiveness of the injectable bulking agent Opsys® (Promedon, Cordoba, Argentina) for treating minimal postprostatectomy stress urinary incontinence (SUI). PATIENTS AND METHODS: Single-centre, pilot study on ten male patients with SUI, < 30 g urine loss/ 24 h, more than 1 year after radical prostatectomy. Patients were treated by endoscopic transurethral injections of bulking agent in the presphincteric zone of the urethral submucosa. The results were evaluated using a pad weight test to quantify the differences in urine loss at 1, 3, and 6 months after intervention. Subsequently, the results of treatment were also evaluated by International Consultation on Incontinence Questionnaire Short Form (ICIQ-SF), Incontinence Impact Questionnaire (IIQ-7), Urogenital Distress Inventory Short Form (UDI-6-SF), and the Patient Global Impression of Improvement (PGI-I) at 1, 3, and 6 months after intervention. RESULTS: The primary outcome was the absolute result of the 24-hour pad weight test after treatment. Treatment success was defined as <3 g urine loss/24 h, improvement as ≥50% decrease in urine loss/ 24h, failure as <50% decrease in urine loss/24 h, or worsening of urine loss. Success was demonstrated in one, improvement in one, and failure in eight patients one month after treatment. One patient improved and 9 failed 3 and 6 months after treatment. The median 24-hour pad weight test was higher at all three moments of follow-up (1, 3, and 6 months after treatment). The median 24-hour pad weight test was before treatment 17.3g (6.4-20.9) and 1, 3, and 6 months after treatment, respectively, 40.3g (5.9-130.6) p= 0.038, 38.3g (18.3-202.1) p= 0.014, 55.0g (16.5-314.6) p= 0.028. The ICIQ-SF was significantly higher at 3 and 6 months, respectively 15.0 (12.0-18.5) p= 0.007 and 16.0 (12.5-17.5) p=0.012 versus 10.0 (9.0-12.0) before injection. No significant differences were found between IIQ-7, UDI-6-SF, and PGI-I before and after injection. Complications occurred in four patients: two patients reported spontaneously resolved haematuria and two patients reported urinary frequency. All complications were classified as Clavien–Dindo 1. CONCLUSION: Injection therapy with Opsys® bulking agent is not an effective treatment option for male SUI after radical prostatectomy. It is not a safe treatment option, due to worsening urine loss after treatment.
format Online
Article
Text
id pubmed-6304605
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-63046052019-01-09 Injectable Bulking Agent to Treat Postprostatectomy Urinary Incontinence: A Safety and Effectiveness Pilot Study van Uhm, Janneke I. M. Vermeer, Marloes Elzevier, Henk W. Noordzij, Joop W. Koldewijn, Evert L. Cornel, Erik B. Biomed Res Int Research Article OBJECTIVES: To evaluate the safety and effectiveness of the injectable bulking agent Opsys® (Promedon, Cordoba, Argentina) for treating minimal postprostatectomy stress urinary incontinence (SUI). PATIENTS AND METHODS: Single-centre, pilot study on ten male patients with SUI, < 30 g urine loss/ 24 h, more than 1 year after radical prostatectomy. Patients were treated by endoscopic transurethral injections of bulking agent in the presphincteric zone of the urethral submucosa. The results were evaluated using a pad weight test to quantify the differences in urine loss at 1, 3, and 6 months after intervention. Subsequently, the results of treatment were also evaluated by International Consultation on Incontinence Questionnaire Short Form (ICIQ-SF), Incontinence Impact Questionnaire (IIQ-7), Urogenital Distress Inventory Short Form (UDI-6-SF), and the Patient Global Impression of Improvement (PGI-I) at 1, 3, and 6 months after intervention. RESULTS: The primary outcome was the absolute result of the 24-hour pad weight test after treatment. Treatment success was defined as <3 g urine loss/24 h, improvement as ≥50% decrease in urine loss/ 24h, failure as <50% decrease in urine loss/24 h, or worsening of urine loss. Success was demonstrated in one, improvement in one, and failure in eight patients one month after treatment. One patient improved and 9 failed 3 and 6 months after treatment. The median 24-hour pad weight test was higher at all three moments of follow-up (1, 3, and 6 months after treatment). The median 24-hour pad weight test was before treatment 17.3g (6.4-20.9) and 1, 3, and 6 months after treatment, respectively, 40.3g (5.9-130.6) p= 0.038, 38.3g (18.3-202.1) p= 0.014, 55.0g (16.5-314.6) p= 0.028. The ICIQ-SF was significantly higher at 3 and 6 months, respectively 15.0 (12.0-18.5) p= 0.007 and 16.0 (12.5-17.5) p=0.012 versus 10.0 (9.0-12.0) before injection. No significant differences were found between IIQ-7, UDI-6-SF, and PGI-I before and after injection. Complications occurred in four patients: two patients reported spontaneously resolved haematuria and two patients reported urinary frequency. All complications were classified as Clavien–Dindo 1. CONCLUSION: Injection therapy with Opsys® bulking agent is not an effective treatment option for male SUI after radical prostatectomy. It is not a safe treatment option, due to worsening urine loss after treatment. Hindawi 2018-12-06 /pmc/articles/PMC6304605/ /pubmed/30627546 http://dx.doi.org/10.1155/2018/2796967 Text en Copyright © 2018 Janneke I. M. van Uhm et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
van Uhm, Janneke I. M.
Vermeer, Marloes
Elzevier, Henk W.
Noordzij, Joop W.
Koldewijn, Evert L.
Cornel, Erik B.
Injectable Bulking Agent to Treat Postprostatectomy Urinary Incontinence: A Safety and Effectiveness Pilot Study
title Injectable Bulking Agent to Treat Postprostatectomy Urinary Incontinence: A Safety and Effectiveness Pilot Study
title_full Injectable Bulking Agent to Treat Postprostatectomy Urinary Incontinence: A Safety and Effectiveness Pilot Study
title_fullStr Injectable Bulking Agent to Treat Postprostatectomy Urinary Incontinence: A Safety and Effectiveness Pilot Study
title_full_unstemmed Injectable Bulking Agent to Treat Postprostatectomy Urinary Incontinence: A Safety and Effectiveness Pilot Study
title_short Injectable Bulking Agent to Treat Postprostatectomy Urinary Incontinence: A Safety and Effectiveness Pilot Study
title_sort injectable bulking agent to treat postprostatectomy urinary incontinence: a safety and effectiveness pilot study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6304605/
https://www.ncbi.nlm.nih.gov/pubmed/30627546
http://dx.doi.org/10.1155/2018/2796967
work_keys_str_mv AT vanuhmjannekeim injectablebulkingagenttotreatpostprostatectomyurinaryincontinenceasafetyandeffectivenesspilotstudy
AT vermeermarloes injectablebulkingagenttotreatpostprostatectomyurinaryincontinenceasafetyandeffectivenesspilotstudy
AT elzevierhenkw injectablebulkingagenttotreatpostprostatectomyurinaryincontinenceasafetyandeffectivenesspilotstudy
AT noordzijjoopw injectablebulkingagenttotreatpostprostatectomyurinaryincontinenceasafetyandeffectivenesspilotstudy
AT koldewijnevertl injectablebulkingagenttotreatpostprostatectomyurinaryincontinenceasafetyandeffectivenesspilotstudy
AT cornelerikb injectablebulkingagenttotreatpostprostatectomyurinaryincontinenceasafetyandeffectivenesspilotstudy