Cargando…

Pharmacokinetic Study of Sirolimus-Eluting BioResorbable Vascular Scaffold System for Treatment of De Novo Native Coronary Lesions: A Sub-Study of MeRes-1 Trial

BACKGROUND: MeRes100™ (Meril Life Sciences Pvt. Ltd., Vapi, India) is a novel sirolimus-eluting bioresorbable vascular scaffold (BRS). The purpose of this sub-study of MeRes-1 trial is to evaluate the systemic release of sirolimus from MeRes100 BRS implanted for the treatment of de novo native coron...

Descripción completa

Detalles Bibliográficos
Autores principales: Chandra, Praveen, Mahajan, Ajaykumar U., Bulani, Vipin D., Thakkar, Ashok S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elmer Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6306117/
https://www.ncbi.nlm.nih.gov/pubmed/30627287
http://dx.doi.org/10.14740/cr799
_version_ 1783382714157629440
author Chandra, Praveen
Mahajan, Ajaykumar U.
Bulani, Vipin D.
Thakkar, Ashok S.
author_facet Chandra, Praveen
Mahajan, Ajaykumar U.
Bulani, Vipin D.
Thakkar, Ashok S.
author_sort Chandra, Praveen
collection PubMed
description BACKGROUND: MeRes100™ (Meril Life Sciences Pvt. Ltd., Vapi, India) is a novel sirolimus-eluting bioresorbable vascular scaffold (BRS). The purpose of this sub-study of MeRes-1 trial is to evaluate the systemic release of sirolimus from MeRes100 BRS implanted for the treatment of de novo native coronary artery lesions. METHODS: The MeRes-1 is a prospective, multicenter, first-in-human trial of sirolimus-eluting MeRes100 BRS. The pharmacokinetic sub-study was conducted at two Indian sites in 10 patients who were implanted with the MeRes100 BRS loaded with sirolimus at a dose of 1.25 µg/mm(2). Venous blood samples were collected at pre-dose and 12-time points after implantation of the scaffold. Sirolimus concentration was successively analyzed using ultra-performance liquid chromatography-electrospray ionization tandem mass spectrometry method. RESULTS: A total of 12 scaffolds were implanted in 10 patients. Non-compartmental analysis demonstrated time to reach peak concentration of sirolimus between 0.5 h to 3 h after scaffold implantation. The peak concentration (C(max)) was deduced to be 7.47 ± 2.61 ng/mL, AUC was 436.45 ± 171.24 h·ng/mL, and the t(½) was observed at 98.59 ± 33.58 h. The clearance was 0.66 ± 0.16 L/h and lower limit of quantification was detectable at 14.1 days. CONCLUSIONS: The MeRes-1 pharmacokinetic sub-study confirmed that MeRes100 BRS is safe and tolerable at limited systemic exposure of sirolimus.
format Online
Article
Text
id pubmed-6306117
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elmer Press
record_format MEDLINE/PubMed
spelling pubmed-63061172019-01-09 Pharmacokinetic Study of Sirolimus-Eluting BioResorbable Vascular Scaffold System for Treatment of De Novo Native Coronary Lesions: A Sub-Study of MeRes-1 Trial Chandra, Praveen Mahajan, Ajaykumar U. Bulani, Vipin D. Thakkar, Ashok S. Cardiol Res Original Article BACKGROUND: MeRes100™ (Meril Life Sciences Pvt. Ltd., Vapi, India) is a novel sirolimus-eluting bioresorbable vascular scaffold (BRS). The purpose of this sub-study of MeRes-1 trial is to evaluate the systemic release of sirolimus from MeRes100 BRS implanted for the treatment of de novo native coronary artery lesions. METHODS: The MeRes-1 is a prospective, multicenter, first-in-human trial of sirolimus-eluting MeRes100 BRS. The pharmacokinetic sub-study was conducted at two Indian sites in 10 patients who were implanted with the MeRes100 BRS loaded with sirolimus at a dose of 1.25 µg/mm(2). Venous blood samples were collected at pre-dose and 12-time points after implantation of the scaffold. Sirolimus concentration was successively analyzed using ultra-performance liquid chromatography-electrospray ionization tandem mass spectrometry method. RESULTS: A total of 12 scaffolds were implanted in 10 patients. Non-compartmental analysis demonstrated time to reach peak concentration of sirolimus between 0.5 h to 3 h after scaffold implantation. The peak concentration (C(max)) was deduced to be 7.47 ± 2.61 ng/mL, AUC was 436.45 ± 171.24 h·ng/mL, and the t(½) was observed at 98.59 ± 33.58 h. The clearance was 0.66 ± 0.16 L/h and lower limit of quantification was detectable at 14.1 days. CONCLUSIONS: The MeRes-1 pharmacokinetic sub-study confirmed that MeRes100 BRS is safe and tolerable at limited systemic exposure of sirolimus. Elmer Press 2018-12 2018-12-07 /pmc/articles/PMC6306117/ /pubmed/30627287 http://dx.doi.org/10.14740/cr799 Text en Copyright 2018, Chandra et al. http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Non-Commercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Chandra, Praveen
Mahajan, Ajaykumar U.
Bulani, Vipin D.
Thakkar, Ashok S.
Pharmacokinetic Study of Sirolimus-Eluting BioResorbable Vascular Scaffold System for Treatment of De Novo Native Coronary Lesions: A Sub-Study of MeRes-1 Trial
title Pharmacokinetic Study of Sirolimus-Eluting BioResorbable Vascular Scaffold System for Treatment of De Novo Native Coronary Lesions: A Sub-Study of MeRes-1 Trial
title_full Pharmacokinetic Study of Sirolimus-Eluting BioResorbable Vascular Scaffold System for Treatment of De Novo Native Coronary Lesions: A Sub-Study of MeRes-1 Trial
title_fullStr Pharmacokinetic Study of Sirolimus-Eluting BioResorbable Vascular Scaffold System for Treatment of De Novo Native Coronary Lesions: A Sub-Study of MeRes-1 Trial
title_full_unstemmed Pharmacokinetic Study of Sirolimus-Eluting BioResorbable Vascular Scaffold System for Treatment of De Novo Native Coronary Lesions: A Sub-Study of MeRes-1 Trial
title_short Pharmacokinetic Study of Sirolimus-Eluting BioResorbable Vascular Scaffold System for Treatment of De Novo Native Coronary Lesions: A Sub-Study of MeRes-1 Trial
title_sort pharmacokinetic study of sirolimus-eluting bioresorbable vascular scaffold system for treatment of de novo native coronary lesions: a sub-study of meres-1 trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6306117/
https://www.ncbi.nlm.nih.gov/pubmed/30627287
http://dx.doi.org/10.14740/cr799
work_keys_str_mv AT chandrapraveen pharmacokineticstudyofsirolimuselutingbioresorbablevascularscaffoldsystemfortreatmentofdenovonativecoronarylesionsasubstudyofmeres1trial
AT mahajanajaykumaru pharmacokineticstudyofsirolimuselutingbioresorbablevascularscaffoldsystemfortreatmentofdenovonativecoronarylesionsasubstudyofmeres1trial
AT bulanivipind pharmacokineticstudyofsirolimuselutingbioresorbablevascularscaffoldsystemfortreatmentofdenovonativecoronarylesionsasubstudyofmeres1trial
AT thakkarashoks pharmacokineticstudyofsirolimuselutingbioresorbablevascularscaffoldsystemfortreatmentofdenovonativecoronarylesionsasubstudyofmeres1trial