Cargando…

Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study

OBJECTIVE: This study was performed to explore the effect of different bracket, archwire, and ligature combinations on resistance to sliding (RS) and rotational control in first-order angulation. METHODS: Three types of brackets (multi-level low friction [MLF], self-ligating, and conventional bracke...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Huizhong, Han, Bing, Xu, Tianmin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Association of Orthodontists 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6306321/
https://www.ncbi.nlm.nih.gov/pubmed/30603622
http://dx.doi.org/10.4041/kjod.2019.49.1.21
_version_ 1783382754658877440
author Chen, Huizhong
Han, Bing
Xu, Tianmin
author_facet Chen, Huizhong
Han, Bing
Xu, Tianmin
author_sort Chen, Huizhong
collection PubMed
description OBJECTIVE: This study was performed to explore the effect of different bracket, archwire, and ligature combinations on resistance to sliding (RS) and rotational control in first-order angulation. METHODS: Three types of brackets (multi-level low friction [MLF], self-ligating, and conventional brackets) coupled with four nickel-titanium archwires (0.012, 0.014, 0.016, and 0.018-inch diameter) and two stainless steel ligatures (0.20 and 0.25 mm) were tested in different first-order angulations (0°, 2°, 4°, 6°, 8°, 10°, 15°, 20°) by using an Instron universal mechanical machine in the dry state at room temperature. RS value was evaluated and compared by one-way ANOVA. RESULTS: Under the same angulation, the RS values showed the following order: conventional brackets > MLF brackets > self-ligating brackets. The RS was the highest for conventional brackets and showed a tendency to increase. The RS for MLF brackets coupled with thinner archwires and ligatures showed a similar tendency as the RS for the self-ligating bracket. In contrast, the RS for MLF brackets coupled with thicker archwires and ligatures increased like that for conventional brackets. MLF brackets showed the greatest range of critical contact angles in first-order angulation. CONCLUSIONS: The RS in first-order angulation is influenced by bracket design, archwire, and ligature dimension. In comparison with self-ligating and conventional brackets, MLF brackets could express low friction and rotational control with their greater range of critical contact angles.
format Online
Article
Text
id pubmed-6306321
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Korean Association of Orthodontists
record_format MEDLINE/PubMed
spelling pubmed-63063212019-01-03 Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study Chen, Huizhong Han, Bing Xu, Tianmin Korean J Orthod Original Article OBJECTIVE: This study was performed to explore the effect of different bracket, archwire, and ligature combinations on resistance to sliding (RS) and rotational control in first-order angulation. METHODS: Three types of brackets (multi-level low friction [MLF], self-ligating, and conventional brackets) coupled with four nickel-titanium archwires (0.012, 0.014, 0.016, and 0.018-inch diameter) and two stainless steel ligatures (0.20 and 0.25 mm) were tested in different first-order angulations (0°, 2°, 4°, 6°, 8°, 10°, 15°, 20°) by using an Instron universal mechanical machine in the dry state at room temperature. RS value was evaluated and compared by one-way ANOVA. RESULTS: Under the same angulation, the RS values showed the following order: conventional brackets > MLF brackets > self-ligating brackets. The RS was the highest for conventional brackets and showed a tendency to increase. The RS for MLF brackets coupled with thinner archwires and ligatures showed a similar tendency as the RS for the self-ligating bracket. In contrast, the RS for MLF brackets coupled with thicker archwires and ligatures increased like that for conventional brackets. MLF brackets showed the greatest range of critical contact angles in first-order angulation. CONCLUSIONS: The RS in first-order angulation is influenced by bracket design, archwire, and ligature dimension. In comparison with self-ligating and conventional brackets, MLF brackets could express low friction and rotational control with their greater range of critical contact angles. Korean Association of Orthodontists 2019-01 2018-12-19 /pmc/articles/PMC6306321/ /pubmed/30603622 http://dx.doi.org/10.4041/kjod.2019.49.1.21 Text en © 2019 The Korean Association of Orthodontists. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Chen, Huizhong
Han, Bing
Xu, Tianmin
Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study
title Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study
title_full Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study
title_fullStr Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study
title_full_unstemmed Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study
title_short Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study
title_sort effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: an in-vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6306321/
https://www.ncbi.nlm.nih.gov/pubmed/30603622
http://dx.doi.org/10.4041/kjod.2019.49.1.21
work_keys_str_mv AT chenhuizhong effectofdifferentcombinationsofbracketarchwireandligatureonresistancetoslidingandaxialrotationalcontrolduringthefirststageoforthodontictreatmentaninvitrostudy
AT hanbing effectofdifferentcombinationsofbracketarchwireandligatureonresistancetoslidingandaxialrotationalcontrolduringthefirststageoforthodontictreatmentaninvitrostudy
AT xutianmin effectofdifferentcombinationsofbracketarchwireandligatureonresistancetoslidingandaxialrotationalcontrolduringthefirststageoforthodontictreatmentaninvitrostudy