Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study
OBJECTIVE: This study was performed to explore the effect of different bracket, archwire, and ligature combinations on resistance to sliding (RS) and rotational control in first-order angulation. METHODS: Three types of brackets (multi-level low friction [MLF], self-ligating, and conventional bracke...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Association of Orthodontists
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6306321/ https://www.ncbi.nlm.nih.gov/pubmed/30603622 http://dx.doi.org/10.4041/kjod.2019.49.1.21 |
_version_ | 1783382754658877440 |
---|---|
author | Chen, Huizhong Han, Bing Xu, Tianmin |
author_facet | Chen, Huizhong Han, Bing Xu, Tianmin |
author_sort | Chen, Huizhong |
collection | PubMed |
description | OBJECTIVE: This study was performed to explore the effect of different bracket, archwire, and ligature combinations on resistance to sliding (RS) and rotational control in first-order angulation. METHODS: Three types of brackets (multi-level low friction [MLF], self-ligating, and conventional brackets) coupled with four nickel-titanium archwires (0.012, 0.014, 0.016, and 0.018-inch diameter) and two stainless steel ligatures (0.20 and 0.25 mm) were tested in different first-order angulations (0°, 2°, 4°, 6°, 8°, 10°, 15°, 20°) by using an Instron universal mechanical machine in the dry state at room temperature. RS value was evaluated and compared by one-way ANOVA. RESULTS: Under the same angulation, the RS values showed the following order: conventional brackets > MLF brackets > self-ligating brackets. The RS was the highest for conventional brackets and showed a tendency to increase. The RS for MLF brackets coupled with thinner archwires and ligatures showed a similar tendency as the RS for the self-ligating bracket. In contrast, the RS for MLF brackets coupled with thicker archwires and ligatures increased like that for conventional brackets. MLF brackets showed the greatest range of critical contact angles in first-order angulation. CONCLUSIONS: The RS in first-order angulation is influenced by bracket design, archwire, and ligature dimension. In comparison with self-ligating and conventional brackets, MLF brackets could express low friction and rotational control with their greater range of critical contact angles. |
format | Online Article Text |
id | pubmed-6306321 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Korean Association of Orthodontists |
record_format | MEDLINE/PubMed |
spelling | pubmed-63063212019-01-03 Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study Chen, Huizhong Han, Bing Xu, Tianmin Korean J Orthod Original Article OBJECTIVE: This study was performed to explore the effect of different bracket, archwire, and ligature combinations on resistance to sliding (RS) and rotational control in first-order angulation. METHODS: Three types of brackets (multi-level low friction [MLF], self-ligating, and conventional brackets) coupled with four nickel-titanium archwires (0.012, 0.014, 0.016, and 0.018-inch diameter) and two stainless steel ligatures (0.20 and 0.25 mm) were tested in different first-order angulations (0°, 2°, 4°, 6°, 8°, 10°, 15°, 20°) by using an Instron universal mechanical machine in the dry state at room temperature. RS value was evaluated and compared by one-way ANOVA. RESULTS: Under the same angulation, the RS values showed the following order: conventional brackets > MLF brackets > self-ligating brackets. The RS was the highest for conventional brackets and showed a tendency to increase. The RS for MLF brackets coupled with thinner archwires and ligatures showed a similar tendency as the RS for the self-ligating bracket. In contrast, the RS for MLF brackets coupled with thicker archwires and ligatures increased like that for conventional brackets. MLF brackets showed the greatest range of critical contact angles in first-order angulation. CONCLUSIONS: The RS in first-order angulation is influenced by bracket design, archwire, and ligature dimension. In comparison with self-ligating and conventional brackets, MLF brackets could express low friction and rotational control with their greater range of critical contact angles. Korean Association of Orthodontists 2019-01 2018-12-19 /pmc/articles/PMC6306321/ /pubmed/30603622 http://dx.doi.org/10.4041/kjod.2019.49.1.21 Text en © 2019 The Korean Association of Orthodontists. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Chen, Huizhong Han, Bing Xu, Tianmin Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study |
title | Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study |
title_full | Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study |
title_fullStr | Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study |
title_full_unstemmed | Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study |
title_short | Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study |
title_sort | effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: an in-vitro study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6306321/ https://www.ncbi.nlm.nih.gov/pubmed/30603622 http://dx.doi.org/10.4041/kjod.2019.49.1.21 |
work_keys_str_mv | AT chenhuizhong effectofdifferentcombinationsofbracketarchwireandligatureonresistancetoslidingandaxialrotationalcontrolduringthefirststageoforthodontictreatmentaninvitrostudy AT hanbing effectofdifferentcombinationsofbracketarchwireandligatureonresistancetoslidingandaxialrotationalcontrolduringthefirststageoforthodontictreatmentaninvitrostudy AT xutianmin effectofdifferentcombinationsofbracketarchwireandligatureonresistancetoslidingandaxialrotationalcontrolduringthefirststageoforthodontictreatmentaninvitrostudy |