Performance and clinical comparison between left ventricular quadripolar and bipolar leads in cardiac resynchronization therapy: Observational research

AIM: To evaluate Attain Performa (Medtronic, Dublin, Ireland) quadripolar lead performance in clinical practice and, secondarily, to compare its long term clinical outcomes vs bipolar leads for left ventricular (LV) pacing. METHODS AND RESULTS: We retrospectively analyzed clinical, procedural and fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Ziacchi, M., Zucchelli, G., Ricciardi, D., Morani, G., De Ruvo, E., Calzolari, V., Viani, S., Calabrese, V., Tomasi, L., Calò, L., De Mattia, L., Bongiorni, M.G., Boriani, G., Biffi, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6306340/
https://www.ncbi.nlm.nih.gov/pubmed/30580858
http://dx.doi.org/10.1016/j.ihj.2018.05.007
_version_ 1783382759262126080
author Ziacchi, M.
Zucchelli, G.
Ricciardi, D.
Morani, G.
De Ruvo, E.
Calzolari, V.
Viani, S.
Calabrese, V.
Tomasi, L.
Calò, L.
De Mattia, L.
Bongiorni, M.G.
Boriani, G.
Biffi, M.
author_facet Ziacchi, M.
Zucchelli, G.
Ricciardi, D.
Morani, G.
De Ruvo, E.
Calzolari, V.
Viani, S.
Calabrese, V.
Tomasi, L.
Calò, L.
De Mattia, L.
Bongiorni, M.G.
Boriani, G.
Biffi, M.
author_sort Ziacchi, M.
collection PubMed
description AIM: To evaluate Attain Performa (Medtronic, Dublin, Ireland) quadripolar lead performance in clinical practice and, secondarily, to compare its long term clinical outcomes vs bipolar leads for left ventricular (LV) pacing. METHODS AND RESULTS: We retrospectively analyzed clinical, procedural and follow-up data of 215 patients implanted with a quadripolar lead. One hundred and twenty one patients implanted with bipolar lead were selected to compare long-term clinical outcomes. The quadripolar lead was implanted in the target vein in 196 patients (91%) without acute dislodgements. In 50% of patients the chosen final pacing configuration at implant would not have been available with bipolar leads. A dedicated quadripolar pacing vector was chosen more frequently when the LV tip location was apical than otherwise (65.6% vs 42.7%, p = 0.003). After a median follow-up of 14 months, the LV pacing threshold was less than 2.5 V at 0.4 ms in 98 patients (90%) with a safety margin between phrenic nerve and LV pacing threshold >3 V in 97 patients (89%). We observed a slight trend toward a lower risk of heart failure worsening and a lower incidence of ventricular arrhythmias and pulmonary congestion in patients implanted with quadripolar leads compared with the control group. CONCLUSION: Quadripolar leads improve the management of phrenic nerve stimulation at no trade-off with pacing threshold and lead stability. Quadripolar leads seems to be associated with a lower incidence of VT/VF and pulmonary congestion, when compared with bipolar leads, but further investigations are necessary to confirm that this positive effect is associated with better LV reverse remodeling.
format Online
Article
Text
id pubmed-6306340
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-63063402019-11-01 Performance and clinical comparison between left ventricular quadripolar and bipolar leads in cardiac resynchronization therapy: Observational research Ziacchi, M. Zucchelli, G. Ricciardi, D. Morani, G. De Ruvo, E. Calzolari, V. Viani, S. Calabrese, V. Tomasi, L. Calò, L. De Mattia, L. Bongiorni, M.G. Boriani, G. Biffi, M. Indian Heart J Cardiac Electrophysiology AIM: To evaluate Attain Performa (Medtronic, Dublin, Ireland) quadripolar lead performance in clinical practice and, secondarily, to compare its long term clinical outcomes vs bipolar leads for left ventricular (LV) pacing. METHODS AND RESULTS: We retrospectively analyzed clinical, procedural and follow-up data of 215 patients implanted with a quadripolar lead. One hundred and twenty one patients implanted with bipolar lead were selected to compare long-term clinical outcomes. The quadripolar lead was implanted in the target vein in 196 patients (91%) without acute dislodgements. In 50% of patients the chosen final pacing configuration at implant would not have been available with bipolar leads. A dedicated quadripolar pacing vector was chosen more frequently when the LV tip location was apical than otherwise (65.6% vs 42.7%, p = 0.003). After a median follow-up of 14 months, the LV pacing threshold was less than 2.5 V at 0.4 ms in 98 patients (90%) with a safety margin between phrenic nerve and LV pacing threshold >3 V in 97 patients (89%). We observed a slight trend toward a lower risk of heart failure worsening and a lower incidence of ventricular arrhythmias and pulmonary congestion in patients implanted with quadripolar leads compared with the control group. CONCLUSION: Quadripolar leads improve the management of phrenic nerve stimulation at no trade-off with pacing threshold and lead stability. Quadripolar leads seems to be associated with a lower incidence of VT/VF and pulmonary congestion, when compared with bipolar leads, but further investigations are necessary to confirm that this positive effect is associated with better LV reverse remodeling. Elsevier 2018 2018-05-16 /pmc/articles/PMC6306340/ /pubmed/30580858 http://dx.doi.org/10.1016/j.ihj.2018.05.007 Text en © 2018 Cardiological Society of India. Published by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Cardiac Electrophysiology
Ziacchi, M.
Zucchelli, G.
Ricciardi, D.
Morani, G.
De Ruvo, E.
Calzolari, V.
Viani, S.
Calabrese, V.
Tomasi, L.
Calò, L.
De Mattia, L.
Bongiorni, M.G.
Boriani, G.
Biffi, M.
Performance and clinical comparison between left ventricular quadripolar and bipolar leads in cardiac resynchronization therapy: Observational research
title Performance and clinical comparison between left ventricular quadripolar and bipolar leads in cardiac resynchronization therapy: Observational research
title_full Performance and clinical comparison between left ventricular quadripolar and bipolar leads in cardiac resynchronization therapy: Observational research
title_fullStr Performance and clinical comparison between left ventricular quadripolar and bipolar leads in cardiac resynchronization therapy: Observational research
title_full_unstemmed Performance and clinical comparison between left ventricular quadripolar and bipolar leads in cardiac resynchronization therapy: Observational research
title_short Performance and clinical comparison between left ventricular quadripolar and bipolar leads in cardiac resynchronization therapy: Observational research
title_sort performance and clinical comparison between left ventricular quadripolar and bipolar leads in cardiac resynchronization therapy: observational research
topic Cardiac Electrophysiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6306340/
https://www.ncbi.nlm.nih.gov/pubmed/30580858
http://dx.doi.org/10.1016/j.ihj.2018.05.007
work_keys_str_mv AT ziacchim performanceandclinicalcomparisonbetweenleftventricularquadripolarandbipolarleadsincardiacresynchronizationtherapyobservationalresearch
AT zucchellig performanceandclinicalcomparisonbetweenleftventricularquadripolarandbipolarleadsincardiacresynchronizationtherapyobservationalresearch
AT ricciardid performanceandclinicalcomparisonbetweenleftventricularquadripolarandbipolarleadsincardiacresynchronizationtherapyobservationalresearch
AT moranig performanceandclinicalcomparisonbetweenleftventricularquadripolarandbipolarleadsincardiacresynchronizationtherapyobservationalresearch
AT deruvoe performanceandclinicalcomparisonbetweenleftventricularquadripolarandbipolarleadsincardiacresynchronizationtherapyobservationalresearch
AT calzolariv performanceandclinicalcomparisonbetweenleftventricularquadripolarandbipolarleadsincardiacresynchronizationtherapyobservationalresearch
AT vianis performanceandclinicalcomparisonbetweenleftventricularquadripolarandbipolarleadsincardiacresynchronizationtherapyobservationalresearch
AT calabresev performanceandclinicalcomparisonbetweenleftventricularquadripolarandbipolarleadsincardiacresynchronizationtherapyobservationalresearch
AT tomasil performanceandclinicalcomparisonbetweenleftventricularquadripolarandbipolarleadsincardiacresynchronizationtherapyobservationalresearch
AT calol performanceandclinicalcomparisonbetweenleftventricularquadripolarandbipolarleadsincardiacresynchronizationtherapyobservationalresearch
AT demattial performanceandclinicalcomparisonbetweenleftventricularquadripolarandbipolarleadsincardiacresynchronizationtherapyobservationalresearch
AT bongiornimg performanceandclinicalcomparisonbetweenleftventricularquadripolarandbipolarleadsincardiacresynchronizationtherapyobservationalresearch
AT borianig performanceandclinicalcomparisonbetweenleftventricularquadripolarandbipolarleadsincardiacresynchronizationtherapyobservationalresearch
AT biffim performanceandclinicalcomparisonbetweenleftventricularquadripolarandbipolarleadsincardiacresynchronizationtherapyobservationalresearch