Cargando…

New approach to environmental investigation of an explosive legionnaires´ disease outbreak in Spain: early identification of potential risk sources by rapid Legionella spp immunosensing technique

BACKGROUND: An explosive outbreak of Legionnaires’ disease (LD) was identified on 11 December 2015 in Manzanares, Ciudad Real, Spain, and was declared closed by 03 February 2016. The number of declared cases was 593 with 277 confirmed cases so that it can be considered as one of the outbreaks with h...

Descripción completa

Detalles Bibliográficos
Autores principales: Cebrián, Fernando, Montero, Juan C., Fernández, Pedro J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6307211/
https://www.ncbi.nlm.nih.gov/pubmed/30587144
http://dx.doi.org/10.1186/s12879-018-3605-8
_version_ 1783382954857201664
author Cebrián, Fernando
Montero, Juan C.
Fernández, Pedro J.
author_facet Cebrián, Fernando
Montero, Juan C.
Fernández, Pedro J.
author_sort Cebrián, Fernando
collection PubMed
description BACKGROUND: An explosive outbreak of Legionnaires’ disease (LD) was identified on 11 December 2015 in Manzanares, Ciudad Real, Spain, and was declared closed by 03 February 2016. The number of declared cases was 593 with 277 confirmed cases so that it can be considered as one of the outbreaks with highest attack rate. This rate could be attributed to the ageing of the population, among others, in addition to various risk factors and habits, and the meteorological conditions (thermal inversion) maintained in this municipality at the time. The Public Health Services succeeded in breaking the bacterial transmission. Several facilities were early identified by microbiological analysis, including a cooling tower and a decorative fountain, as possible infectious sources. Rapid analytical techniques for rapid Legionella detection and the shutdown and preventative closure of positive installations have been considered key elements in the control of this outbreak. RESULTS: Rapid microbiological analysis helped to the early identification of potential risk sources in a Legionnaires´ disease outbreak, reducing decision-making processes according to the actual needs of the intervention in public health and shortening the exposure of the population. CONCLUSIONS: Protocolized and immediate intervention in an outbreak is a crucial issue to reduce their effects on public health. For this, identification and control of the suspicious sources able to disseminate the bacteria and cause the illness is required. Rapid analytical techniques like immunomagnetic separation (IMS) method based on the whole bacterial cell detection are shown as excellent tools to investigate all the potential sources of risk.
format Online
Article
Text
id pubmed-6307211
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-63072112019-01-02 New approach to environmental investigation of an explosive legionnaires´ disease outbreak in Spain: early identification of potential risk sources by rapid Legionella spp immunosensing technique Cebrián, Fernando Montero, Juan C. Fernández, Pedro J. BMC Infect Dis Research Article BACKGROUND: An explosive outbreak of Legionnaires’ disease (LD) was identified on 11 December 2015 in Manzanares, Ciudad Real, Spain, and was declared closed by 03 February 2016. The number of declared cases was 593 with 277 confirmed cases so that it can be considered as one of the outbreaks with highest attack rate. This rate could be attributed to the ageing of the population, among others, in addition to various risk factors and habits, and the meteorological conditions (thermal inversion) maintained in this municipality at the time. The Public Health Services succeeded in breaking the bacterial transmission. Several facilities were early identified by microbiological analysis, including a cooling tower and a decorative fountain, as possible infectious sources. Rapid analytical techniques for rapid Legionella detection and the shutdown and preventative closure of positive installations have been considered key elements in the control of this outbreak. RESULTS: Rapid microbiological analysis helped to the early identification of potential risk sources in a Legionnaires´ disease outbreak, reducing decision-making processes according to the actual needs of the intervention in public health and shortening the exposure of the population. CONCLUSIONS: Protocolized and immediate intervention in an outbreak is a crucial issue to reduce their effects on public health. For this, identification and control of the suspicious sources able to disseminate the bacteria and cause the illness is required. Rapid analytical techniques like immunomagnetic separation (IMS) method based on the whole bacterial cell detection are shown as excellent tools to investigate all the potential sources of risk. BioMed Central 2018-12-27 /pmc/articles/PMC6307211/ /pubmed/30587144 http://dx.doi.org/10.1186/s12879-018-3605-8 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Cebrián, Fernando
Montero, Juan C.
Fernández, Pedro J.
New approach to environmental investigation of an explosive legionnaires´ disease outbreak in Spain: early identification of potential risk sources by rapid Legionella spp immunosensing technique
title New approach to environmental investigation of an explosive legionnaires´ disease outbreak in Spain: early identification of potential risk sources by rapid Legionella spp immunosensing technique
title_full New approach to environmental investigation of an explosive legionnaires´ disease outbreak in Spain: early identification of potential risk sources by rapid Legionella spp immunosensing technique
title_fullStr New approach to environmental investigation of an explosive legionnaires´ disease outbreak in Spain: early identification of potential risk sources by rapid Legionella spp immunosensing technique
title_full_unstemmed New approach to environmental investigation of an explosive legionnaires´ disease outbreak in Spain: early identification of potential risk sources by rapid Legionella spp immunosensing technique
title_short New approach to environmental investigation of an explosive legionnaires´ disease outbreak in Spain: early identification of potential risk sources by rapid Legionella spp immunosensing technique
title_sort new approach to environmental investigation of an explosive legionnaires´ disease outbreak in spain: early identification of potential risk sources by rapid legionella spp immunosensing technique
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6307211/
https://www.ncbi.nlm.nih.gov/pubmed/30587144
http://dx.doi.org/10.1186/s12879-018-3605-8
work_keys_str_mv AT cebrianfernando newapproachtoenvironmentalinvestigationofanexplosivelegionnairesdiseaseoutbreakinspainearlyidentificationofpotentialrisksourcesbyrapidlegionellasppimmunosensingtechnique
AT monterojuanc newapproachtoenvironmentalinvestigationofanexplosivelegionnairesdiseaseoutbreakinspainearlyidentificationofpotentialrisksourcesbyrapidlegionellasppimmunosensingtechnique
AT fernandezpedroj newapproachtoenvironmentalinvestigationofanexplosivelegionnairesdiseaseoutbreakinspainearlyidentificationofpotentialrisksourcesbyrapidlegionellasppimmunosensingtechnique